Your browser doesn't support javascript.
loading
Redesigned Electrodes for Improved Intraoperative Nerve Conduction Studies during the Treatment of Peripheral Nerve Injuries.
Riemann, Nathaniel; Coursen, Jack; Porras, Laura Elena; Sabogal, Bryan; Liang, Xin-Hua; Guaraca, Christian; Belzberg, Allan; Ringkamp, Matthias; Wu, Gang; Zhu, Lily; Weed, Samantha; Miranda, Constanza.
Afiliação
  • Riemann N; Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
  • Coursen J; Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
  • Porras LE; Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
  • Sabogal B; Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
  • Liang XH; Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
  • Guaraca C; Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
  • Belzberg A; Department of Neurosurgery, School of Medicine, Johns Hopkins University, Baltimore, MD 21287, USA.
  • Ringkamp M; Department of Neurosurgery, School of Medicine, Johns Hopkins University, Baltimore, MD 21287, USA.
  • Wu G; Department of Neurosurgery, School of Medicine, Johns Hopkins University, Baltimore, MD 21287, USA.
  • Zhu L; Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
  • Weed S; Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
  • Miranda C; Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
Healthcare (Basel) ; 12(13)2024 Jun 26.
Article em En | MEDLINE | ID: mdl-38998805
ABSTRACT
Traumatic peripheral nerve injuries (PNI), present with symptoms ranging from pain to loss of motor and sensory function. Difficulties in intraoperative visual assessment of nerve functional status necessitate intraoperative nerve conduction studies (INCSs) by neurosurgeons and neurologists to determine the presence of functioning axons in the zone of a PNI. This process, also referred to as nerve "inching", uses a set of stimulating and recording electrode hooks to lift the injured nerve from the surrounding surgical field and to determine whether an electrical stimulus can travel through the zone of injury. However, confounding electrical signal artifacts can arise from the current workflow and electrode design, particularly from the mandatory lifting of the nerve, complicating the definitive assessment of nerve function and neurosurgical treatment decision-making. The objective of this study is to describe the design process and verification testing of our group's newly designed stimulating and recording electrodes that do not require the lifting or displacement of the injured nerve during INCSs. Ergonomic in vivo analysis of the device within a porcine model demonstrated successful intraoperative manipulation of the device, while quantitative nerve action potential (NAP) signal analysis with an ex vivo simulated "inching" procedure on healthy non-human primate nerve tissue demonstrated excellent reproducible recorded NAP fidelity and the absence of NAP signal artifacts at all points of recording. Lastly, electrode pullout force testing determined maximum forces of 0.43 N, 1.57 N, and 3.61 N required to remove the device from 2 mm, 5 mm, and 1 cm nerve models, respectively, which are well within established thresholds for nerve safety. These results suggest that these new electrodes can safely and successfully perform accurate PNI assessment without the presence of artifacts, with the potential to improve the INCS standard of care while remaining compatible with currently used neurosurgical technology, infrastructure, and clinical workflows.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article