Your browser doesn't support javascript.
loading
Retardation of the C-Steel Destruction in Hydrochloric Acid Media Utilizing an Effective Schiff Base Inhibitor: Experimental and Theoretical Computations.
Saleh, Mahmoud G Aboubakr; Alfakeer, Majda; Felaly, Rasha N; Al-Sharif, Merfat S; Al-Juaid, Salih S; Soliman, Kamal A; Hegazy, Mohamed A; Nooh, Sameer; Abdallah, Metwally; El Wanees, Salah Abd.
Afiliação
  • Saleh MGA; Department of Chemistry, College of Science, Northern Border University, Arar 91431, Saudi Arabia.
  • Alfakeer M; Chemistry Department, College of Science, Princess Nourah Bint Abdulrahman University, Riyadh 11564, Saudi Arabia.
  • Felaly RN; Chemistry Department, Faculty of Science, Umm Al-Qura University, Makkah 24382, Saudi Arabia.
  • Al-Sharif MS; Chemistry Department, College of Science, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia.
  • Al-Juaid SS; Chemistry Department, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia.
  • Soliman KA; Chemistry Department, Faculty of Science, Benha University, Benha 13518, Egypt.
  • Hegazy MA; Egyptian Petroleum Research Institute, Cairo 11727, Egypt.
  • Nooh S; Department of Information Systems, Faculty of Computing and Information Technology, King Abdulaziz University, Jeddah 21589, Saudi Arabia.
  • Abdallah M; Chemistry Department, Faculty of Science, Benha University, Benha 13518, Egypt.
  • El Wanees SA; Chemistry Department, Faculty of Applied Science, Umm Al-Qura University, Makkah 24382, Saudi Arabia.
ACS Omega ; 9(27): 29666-29681, 2024 Jul 09.
Article em En | MEDLINE | ID: mdl-39005820
ABSTRACT
The corrosion inhibition of (N 1 E)-N 1,N 2-bis(4-(dimethylamino)benzylidene)-ethane-1,2-diamine, DMAB, against the destruction of C-steel in dilute HCl media (1.0 M) was examined. The techniques of gravimetry, gasometry, potentiodynamic, and electrochemical impedance spectroscopy are utilized. The rate of corrosion is found to decrease with more additions of the DMAB compound. The inhibition efficacy increases with concentrations to reach 97.7% at 5.0 mM and 298 K. The protection of metal destruction is controlled by the adsorption of the DMAB molecules on the metallic surface obeying Langmuir's pattern. The computed ΔG°ads values are characterized by negative sign, explaining the spontaneity of the adsorption process. These values vary between -38.70 and -35.13 kJ mol-1 depending on the temperature, which proves the physio- and chemisorption mechanisms. The reduction in K ads values with T can be attributed to the desorption of some DMAB molecules from the electrode surface. Theoretical quantum computation confirms the adsorption of the DMAB compound in concurrence with the data obtained by practical techniques.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article