Your browser doesn't support javascript.
loading
Value of high-output pace-mapping of the right phrenic nerve for enabling safe radiofrequency ablation of atrial fibrillation: insights from three-dimensional computed tomography segmentation.
Squara, Fabien; Supple, Gregory; Liuba, Ioan; Wasiak, Michal; Zado, Erica; Desjardins, Benoit; Marchlinski, Francis E.
Afiliação
  • Squara F; Department of Cardiology, Pasteur University Hospital, 30 avenue de la Voie Romaine, 06000 Nice, France.
  • Supple G; Department of Cardiac Electrophysiology, Hospital of the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104, USA.
  • Liuba I; Department of Cardiac Electrophysiology, Hospital of the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104, USA.
  • Wasiak M; Department of Cardiac Electrophysiology, Hospital of the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104, USA.
  • Zado E; Department of Cardiac Electrophysiology, Hospital of the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104, USA.
  • Desjardins B; Department of Cardiac Electrophysiology, Hospital of the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104, USA.
  • Marchlinski FE; Department of Radiology, Hospital of the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104, USA.
Europace ; 26(8)2024 Aug 03.
Article em En | MEDLINE | ID: mdl-39082747
ABSTRACT

AIMS:

Right phrenic nerve (RPN) injury is a disabling but uncommon complication of atrial fibrillation (AF) radiofrequency ablation. Pace-mapping is widely used to infer RPN's course, for limiting the risk of palsy by avoiding ablation at capture sites. However, information is lacking regarding the distance between the endocardial sites of capture and the actual anatomic RPN location. We aimed at determining the distance between endocardial sites of capture and anatomic CT location of the RPN, depending on the capture threshold. METHODS AND

RESULTS:

In consecutive patients undergoing AF radiofrequency ablation, we defined the course of the RPN on the electroanatomical map with high-output pacing at up to 50 mA/2 ms, and assessed RPN capture threshold (RPN-t). The true anatomic course of the RPN was delineated and segmented using CT scan, then merged with the electroanatomical map. The distance between pacing sites and the RPN was assessed. In 45 patients, 1033 pacing sites were analysed. Distances from pacing sites to RPN ranged from 7.5 ± 3.0 mm (min 1) when RPN-t was ≤10 mA to 19.2 ± 6.5 mm (min 9.4) in cases of non-capture at 50 mA. A distance to the phrenic nerve > 10 mm was predicted by RPN-t with a ROC curve area of 0.846 [0.821-0.870] (P < 0.001), with Se = 80.8% and Sp = 77.5% if RPN-t > 20 mA, Se = 68.0% and Sp = 91.6% if RPN-t > 30 mA, and Se = 42.4% and Sp = 97.6% if non-capture at 50 mA.

CONCLUSION:

These data emphasize the utility of high-output pace-mapping of the RPN. Non-capture at 50 mA/2 ms demonstrated very high specificity for predicting a distance to the RPN > 10 mm, ensuring safe radiofrequency delivery.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nervo Frênico / Fibrilação Atrial / Valor Preditivo dos Testes / Ablação por Cateter / Imageamento Tridimensional / Traumatismos dos Nervos Periféricos Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nervo Frênico / Fibrilação Atrial / Valor Preditivo dos Testes / Ablação por Cateter / Imageamento Tridimensional / Traumatismos dos Nervos Periféricos Idioma: En Ano de publicação: 2024 Tipo de documento: Article