Method Development and Validation of an Aerosol Sampling Technique for the Analysis of Nicotine in Electronic Cigarette Aerosols.
Dill, Maarten; Deconinck, Eric; Barhdadi, Sophia.
Afiliação
  • Dill M; Sciensano, Scientific Direction Chemical and Physical Health Risks, Service of Medicines and Health Products, J. Wytsmanstraat 14, B-1050 Brussels, Belgium.
  • Deconinck E; Sciensano, Scientific Direction Chemical and Physical Health Risks, Service of Medicines and Health Products, J. Wytsmanstraat 14, B-1050 Brussels, Belgium.
  • Barhdadi S; Sciensano, Scientific Direction Chemical and Physical Health Risks, Service of Medicines and Health Products, J. Wytsmanstraat 14, B-1050 Brussels, Belgium.
Molecules ; 29(15)2024 Jul 25.
Article em En | MEDLINE | ID: mdl-39124892
ABSTRACT
Because of the increasing popularity of e-cigarettes, monitoring the e-cigarette market has become important for national health authorities to guarantee safety and quality. In the EU, the Tobacco Products Directive requires emission studies for e-cigarette products. The absence of industry guidelines for studying these emissions and the lack of proper validation in the literature led us to develop and validate a method using the total error approach for the determination of nicotine in e-cigarette aerosols. A commercial vaping device was used to generate aerosols, which were then collected on Cambridge filter pads and measured for nicotine concentration by UHPLC-DAD after extraction. The method was successfully validated by generating accuracy profiles, which show that the ß-expectation tolerance intervals remained below the acceptance limits of ±20%. Within-run repeatability and intermediate precision were considered acceptable since the highest RSD value obtained was below 5%. The method was applied to 15 commercial e-liquids. A complete validation of a method for the analysis of e-cigarette emissions is presented, including several parameters that impact the accuracy and reproducibility. Similar systematic approaches for method development and validation could be used for other e-cigarette emission analysis methods to ensure the reliability of the measurements.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aerossóis / Sistemas Eletrônicos de Liberação de Nicotina / Nicotina Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aerossóis / Sistemas Eletrônicos de Liberação de Nicotina / Nicotina Idioma: En Ano de publicação: 2024 Tipo de documento: Article