Your browser doesn't support javascript.
loading
Usefulness of color Doppler and strain elastography adjunctive to B-mode ultrasonography in the diagnosis of non-mass abnormalities of the breast: results of the BC-07 multicenter study of 385 cases.
Okuno, Toshitaka; Watanabe, Takanori; Yamaguchi, Takuhiro; Konno, Sachiyo; Takaki, Rie; Watanabe, Ryoji; Ban, Kanako; Hirokaga, Koichi; Tsuruoka, Masahiko; Morita, Takako.
Afiliação
  • Okuno T; Department of Breast Surgery, Nishi-Kobe Medical Center, 7-5-1 Koji-dai, Nishi-ku, Kobe City, Kobe, 651-2273, Japan. toshitaka_okuno@kcho.jp.
  • Watanabe T; Department of Breast Surgery, Sendai Medical Center, Sendai, Japan.
  • Yamaguchi T; Division of Biostatistics, Tohoku University Graduate School of Medicine, Sendai, Japan.
  • Konno S; Center of Medical Ultrasonics, Dokkyo Medical University Hospital, Shimotsuga-gun, Mibu, Japan.
  • Takaki R; Department of Clinical Laboratory, Hakuaikai Sagara Hospital, Kagoshima, Japan.
  • Watanabe R; Department of Breast Surgery, Itoshima Medical Association Hospital, Itoshima, Japan.
  • Ban K; Department of Breast Surgery, Yotsuya Medical Cube, Tokyo, Japan.
  • Hirokaga K; Department of Breast Surgery, Hyogo Cancer Center, Akashi, Japan.
  • Tsuruoka M; Department of Radiology, Moriya Keiyu Hospital, Moriya, Japan.
  • Morita T; Department of Breast Surgery, Nagoya Medical Center, Nagoya, Japan.
Article em En | MEDLINE | ID: mdl-39138813
ABSTRACT

PURPOSE:

The concept of non-mass abnormalities of the breast has been employed in Japan for approximately 20 years. Although B-mode findings are classified as non-mass abnormalities, the usefulness of adding color Doppler ultrasonography (US) and strain elastography to B-mode US is unclear. Therefore, we conducted a multicenter study (JABTS BC-07) to establish the diagnostic criteria for breast US, including color Doppler and elastography, for non-mass abnormalities of the breast and verify their diagnostic usefulness.

METHODS:

We registered US images of non-mass abnormalities of the breast and their clinical and histopathological data from 13 institutions (202 malignant and 183 benign non-mass lesions). Furthermore, we evaluated the centralized image interpretation usefulness of the diagnostic criteria for B-mode and color Doppler US, as well as the sensitivity and specificity when color Doppler US and elastography were added to B-mode US.

RESULTS:

Echogenic foci in the mammary gland (odds ratio 3.45, 95% confidence interval [CI] 1.92-6.19, p < 0.0001) and the configuration of internal solid components of the ducts (odds ratio 0.056, 95% CI 0.005-0.591, p < 0.0165) significantly differentiated benign and malignant non-mass abnormalities. The sensitivity of B-mode alone (83.7%) was significantly improved by adding color Doppler US (93.1%) (p = 0.0004); however, adding color Doppler US and elastography to B-mode US made no significant difference in either sensitivity or specificity.

CONCLUSION:

Although adding color Doppler US and elastography to B-mode US improved sensitivity, the diagnostic significance was limited. Therefore, a comprehensive diagnostic method comprising mammography and magnetic resonance imaging is warranted.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article