Your browser doesn't support javascript.
loading
A Clinically Feasible Diagnostic Typing of Breast Cancer Built on a Homogeneous Electrochemical Biosensor for Simultaneous Multiplex Detection.
Zhang, Ya; Ma, WenHao; Li, Ning; Yang, Mei; Hou, Changjun; Huo, Danqun.
Afiliação
  • Zhang Y; Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China.
  • Ma W; Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China.
  • Li N; Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China.
  • Yang M; Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China.
  • Hou C; Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China.
  • Huo D; National Facility for Translational Medicine, Shanghai Jiao Tong University, Shanghai 200240, PR China.
Anal Chem ; 2024 Aug 15.
Article em En | MEDLINE | ID: mdl-39146048
ABSTRACT
Simultaneous detection of multiple tumor markers is of great significance for an accurate diagnosis and early treatment of cancer. Electrochemical homogeneous biosensing strategies have been shown to have advantages, such as high sensitivity and no electrode modification, but they are still a challenge in the field of simultaneous detection of multiple tumor markers. The ER, PR, HER2, and Ki67 proteins are the standard biomarkers for the clinical molecular typing of breast cancer. Precise, sensitive, and simultaneous detection of these four biomarkers is of great importance in the molecular typing of breast cancer, which helps in the creation of personalized treatment plans. In the present study, we developed an electrochemical homogeneous electrochemical bioplatform based on metal ions/SiO2NPs/magnetic beads for detection of the four biomarkers and simultaneous diagnosis of the 10 types of breast cancer directly in human serum at one system by a single electrode. The electrochemical bioplatform has a short detection time of 140 min; however, the current clinical tissue testing time takes about 1 week. Also, the electrochemical bioplatform selectively detects HER2, ER, Ki67, and PR in a range of 0-1000 pg/mL with detection limits of 2, 1.8, 10.36, and 1.33 pg/mL, respectively.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article