Your browser doesn't support javascript.
loading
Glue-Assisted Retinopexy for Retinal Detachments Study Report 2: Fibrin Glue As a Surgical Adjunct in Complex Rhegmatogenous Retinal Detachment.
Desai, Arjun; Bhopalka, Ankit Kumar; Tyagi, Mudit; Sharma, Sumant Vinayak; Takkar, Brijesh.
Afiliação
  • Desai A; Anant Bajaj Retina Institute, LV Prasad Eye Institute, Hyderabad, India.
  • Bhopalka AK; Anant Bajaj Retina Institute, LV Prasad Eye Institute, Hyderabad, India.
  • Tyagi M; Anant Bajaj Retina Institute, LV Prasad Eye Institute, Hyderabad, India.
  • Sharma SV; Anant Bajaj Retina Institute, LV Prasad Eye Institute, Hyderabad, India.
  • Takkar B; Anant Bajaj Retina Institute, LV Prasad Eye Institute, Hyderabad, India.
J Vitreoretin Dis ; 8(4): 435-441, 2024.
Article em En | MEDLINE | ID: mdl-39148571
ABSTRACT

Purpose:

To present the successful application of fibrin glue as a surgical adjunct in the management of complex rhegmatogenous retinal detachment (RRD).

Methods:

In this retrospective case series, fibrin glue was used as a surgical adjunct in 5 cases of complex RRD. In each case, standard pars plana vitrectomy and laser retinopexy were performed by the same surgeon. Fibrin glue was used intraoperatively as a tamponade to seal the breaks because the isolated use of conventional tamponade agents was not feasible given the variable nature of the complex RRDs, the anatomy of the eye, or an inability to maintain postoperative positioning.

Results:

In 1 patient previously treated for a large corneoscleral tear, fibrin glue was used to seal a large iatrogenic retinal break caused by a fragmatome-related surge that led to a quadrantic RD. In 2 patients treated for combined RRD, fibrin glue was used with silicone oil to manage recurrent RRD with incompletely drained thick subretinal fluid and blood. In 2 other cases, fibrin glue was applied to manage RRD in congenital aniridia with advanced glaucoma and aphakia. In all cases, retinal attachment without serious adverse effects was attained over a follow-up ranging from 4 to 6 months.

Conclusions:

Fibrin glue is an effective, safe surgical adjunct in complex RRD. It can be used to transiently seal a retinal break when use of a conventional tamponade agent is not possible or not sufficient alone.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article