Your browser doesn't support javascript.
loading
Novel Discrete and Imprinted Fluoride-Selective Sensors: Bridging the Gap from DMSO to Aqueous Samples.
Quiñone, Delfina; Romano, Giammarco M; Faccio, Ricardo; Savastano, Matteo; Bianchi, Antonio; Bencini, Andrea; Brovetto, Margarita; Torres, Julia; Veiga, Nicolás.
Afiliação
  • Quiñone D; Química Inorgánica, Departamento Estrella Campos, Facultad de Química, Universidad de la República (UdelaR), Av. Gral. Flores 2124, Montevideo, 11800, Uruguay.
  • Romano GM; Graduate Program in Chemistry, Facultad de Química, Universidad de la República, Montevideo, 11800, Uruguay.
  • Faccio R; Department of Chemistry 'Ugo Schiff', University of Florence, Via della Lastruccia 3, Sesto Fiorentino, 50019, Florence, Italy.
  • Savastano M; Área Física, DETEMA, Facultad de Química, Universidad de la República (UdelaR), Av. Gral. Flores 2124, Montevideo, 11800, Uruguay.
  • Bianchi A; Department of Human Sciences for the Promotion of Quality of Life, University San Raffaele Roma, via di Val Cannuta 247, Rome, 00166, Italy.
  • Bencini A; Department of Chemistry 'Ugo Schiff', University of Florence, Via della Lastruccia 3, Sesto Fiorentino, 50019, Florence, Italy.
  • Brovetto M; Department of Chemistry 'Ugo Schiff', University of Florence, Via della Lastruccia 3, Sesto Fiorentino, 50019, Florence, Italy.
  • Torres J; Laboratorio de Síntesis Orgánica, Departamento de Química Orgánica, Facultad de Química, Universidad de la República (UdelaR), Av. Gral. Flores 2124, Montevideo, 11800, Uruguay.
  • Veiga N; Química Inorgánica, Departamento Estrella Campos, Facultad de Química, Universidad de la República (UdelaR), Av. Gral. Flores 2124, Montevideo, 11800, Uruguay.
Small ; : e2402696, 2024 Aug 16.
Article em En | MEDLINE | ID: mdl-39152533
ABSTRACT
Fluoride in drinking water has beneficial or harmful health effects depending on its concentration. This highlights the need for new low-cost and portable sensors capable of in situ monitoring of F- ions. Unfortunately, achieving high levels of water compatibility and fluoride specificity remains a challenge. Here, four new urea-based discrete sensors are prepared and characterized. The sensors containing anthracenyl- (5) and 9H-fluorenyl- (7) signaling units exhibit intense luminescent emissions in dimethyl sulfoxide, the former being particularly sensitive and selective to fluoride. In water, 5 displays a superior sensitivity (871 M-1) and a detection limit (8 µm) below international guidelines, albeit with cross-sensitivity to H2PO4‾. To enhance the performance, 5 and 7 are embedded into a fluoride-imprinted polymeric matrix to give solid-state sensors (5P and 7P, respectively). 5P shows good sensitivity (360 M-1) and specificity in water. Besides, it has a low detection limit (35 µm) and a response linear range (118-6300 µm) encompassing the limit established by the Environmental Protection Agency (211 µm). Furthermore, 5P also displays good reusability and adequate recovery values in real-sample testing (102 ± 2%), constituting the first example of a low-cost anion-imprinted polymeric probe tailored for the selective sensing of fluoride in aqueous samples.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article