A novel implant placement technique using a three-dimensionally printed duplicate denture for implant-supported overdenture in patients with severe residual ridge resorption: A case report.
Clin Case Rep
; 12(9): e9389, 2024 Sep.
Article
em En
| MEDLINE
| ID: mdl-39219780
ABSTRACT
The treatment method of placing a small number of implants in the mandible as a removable implant-supported overdenture (IOD) enables implant placement and denture stability, even in cases with severe residual ridge resorption. In this case report, a new implant placement technique was performed using a three-dimensionally (3D)-printed duplicate denture fabricated by a 3D printer, resulting in the restoration of masticatory function through IOD.