Your browser doesn't support javascript.
loading
Patient-specific arterial input function for accurate perfusion assessment in intraoperative fluorescence imaging.
Tang, Yue; Jiang, Shudong; Sottosanti, Joseph S; Usherwood, Thomas; Cao, Xu; Bateman, Logan M; Fisher, Lillian A; Henderson, Eric R; Gitajn, Ida Leah; Elliott, Jonathan Thomas.
Afiliação
  • Tang Y; Thayer School of Engineering at Dartmouth, Hanover, New Hampshire, United States.
  • Jiang S; Thayer School of Engineering at Dartmouth, Hanover, New Hampshire, United States.
  • Sottosanti JS; Dartmouth Health, Department of Orthopaedics, Lebanon, New Hampshire, United States.
  • Usherwood T; Dartmouth Health, Department of Orthopaedics, Lebanon, New Hampshire, United States.
  • Cao X; Thayer School of Engineering at Dartmouth, Hanover, New Hampshire, United States.
  • Bateman LM; Thayer School of Engineering at Dartmouth, Hanover, New Hampshire, United States.
  • Fisher LA; Dartmouth Health, Department of Orthopaedics, Lebanon, New Hampshire, United States.
  • Henderson ER; Dartmouth Health, Department of Orthopaedics, Lebanon, New Hampshire, United States.
  • Gitajn IL; Dartmouth Health, Department of Orthopaedics, Lebanon, New Hampshire, United States.
  • Elliott JT; Dartmouth Health, Department of Orthopaedics, Lebanon, New Hampshire, United States.
J Biomed Opt ; 29(Suppl 3): S33306, 2024 Jun.
Article em En | MEDLINE | ID: mdl-39247899
ABSTRACT

Significance:

The arterial input function (AIF) plays a crucial role in correcting the time-dependent concentration of the contrast agent within the arterial system, accounting for variations in agent injection parameters (speed, timing, etc.) across patients. Understanding the significance of the AIF can enhance the accuracy of tissue vascular perfusion assessment through indocyanine green-based dynamic contrast-enhanced fluorescence imaging (DCE-FI).

Aim:

We evaluate the impact of the AIF on perfusion assessment through DCE-FI.

Approach:

A total of 144 AIFs were acquired from 110 patients using a pulse dye densitometer. Simulation and patient intraoperative imaging were conducted to validate the significance of AIF for perfusion assessment based on kinetic parameters extracted from fluorescence images before and after AIF correction. The kinetic model accuracy was evaluated by assessing the variability of kinetic parameters using individual AIF versus population-based AIF.

Results:

Individual AIF can reduce the variability in kinetic parameters, and population-based AIF can potentially replace individual AIF for estimating wash-out rate ( k ep ), maximum intensity ( I max ), ingress slope with lower differences compared with those in estimating blood flow, volume transfer constant ( K trans ), and time to peak.

Conclusions:

Individual AIF can provide the most accurate perfusion assessment compared with assessment without AIF or based on population-based AIF correction.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imagem Óptica / Verde de Indocianina Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imagem Óptica / Verde de Indocianina Idioma: En Ano de publicação: 2024 Tipo de documento: Article