Your browser doesn't support javascript.
loading
Study of the Chemical Recovery and Selectivity against U in the Radiochemical Separation of Th with Tri-n-butyl Phosphate by Varying the Proportion of Xylene and HCl Concentration.
Expósito-Suárez, Víctor Manuel; Suárez-Navarro, José Antonio; Benavente, José Francisco.
Afiliação
  • Expósito-Suárez VM; Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), Avenida Complutense 40, 28040 Madrid, Spain.
  • Suárez-Navarro JA; Facultad de Ciencias Químicas, Universidad Complutense de Madrid, Plaza de las Ciencias, 2, Moncloa-Aravaca, 28040 Madrid, Spain.
  • Benavente JF; Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), Avenida Complutense 40, 28040 Madrid, Spain.
Molecules ; 29(17)2024 Sep 05.
Article em En | MEDLINE | ID: mdl-39275073
ABSTRACT
Thorium is a radionuclide used in various environmental studies such as dating, sediment movement, soil-plant transfer studies, and contamination of waste from the natural fuel cycle. The liquid-liquid extraction method using tri-n-butyl phosphate (TBP) allows for the separation of Th from the accompanying actinides. However, the separation of Th and U present in the same sample is not trivial. This separation is influenced by the starting acid (HCl or HNO3), the concentration of TBP in an organic solvent, and the concentration of the acid used for re-extracting Th, which is typically HCl. Therefore, it is necessary to study these factors to ensure that the method has sufficient chemical yield and selectivity in complex matrices. This study presents a systematic investigation of the aforementioned parameters, making the necessary variations to select an optimal method for the radiochemical separation of Th. The ideal conditions were obtained using 4 M HCl as the acid prior to extraction, a 14 solution of TBP in xylene, and 4 M HCl as the re-extracting agent. The accuracy and precision were studied in four intercomparison exercises conducted in quadruplicate, using the parameters Enumbers, RB(%), and RSD(%) for 232Th and 230Th. The sensitivity of the method was experimentally studied and the limit of detection (LoD) was determined according to ISO 119292005. Additionally, the linearity of the method showed that the experimental and theoretical activity concentrations of 232Th and 230Th had slopes of 1 with an intercept close to 0.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article