Your browser doesn't support javascript.
loading
Evaluation of 68Ga-FAPI PET/CT and 18F-FDG PET/CT for the diagnosis of recurrent colorectal cancers.
Xi, Yue; Sun, Yuyun; Gu, Bingxin; Bian, Linjie; Song, Shaoli.
Afiliação
  • Xi Y; Department of Nuclear Medicine, Fudan University Shanghai Cancer Center, Shanghai 200032, China.
  • Sun Y; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032, China.
  • Gu B; Center for Biomedical Imaging, Fudan University, Shanghai 200032, China.
  • Bian L; Shanghai Engineering Research Center of Molecular Imaging Probes, Shanghai 200032, China.
  • Song S; Key Laboratory of Nuclear Physics and Ion-beam Application (MOE), Fudan University, Shanghai 200433, China.
Clin Transl Radiat Oncol ; 49: 100848, 2024 Nov.
Article em En | MEDLINE | ID: mdl-39290456
ABSTRACT

Objective:

The present study aimed to compare the diagnostic value of gallium-68-labeled fibroblast activation protein inhibitor positron emission tomography/computed tomography (68Ga-FAPI PET/CT) and fluorine-18-labeled fluorodeoxyglucose PET/CT (18F-FDG PET/CT) for detecting recurrent colorectal cancers (CRCs). Materials and

Methods:

Fifty-six patients (age 18-80 years, 31 men and 25 women) with suspected recurrent CRC were enrolled and underwent 18F-FDG PET/CT and 68Ga-FAPI PET/CT sequentially within 1 week. The maximum standard uptake value (SUVmax), tumor-to-background ratio (TBR), and diagnostic accuracy were estimated and compared between the two modalities by using Student's t-test. The Wilcoxon signed-rank test was used to compare peritoneal carcinoma index (PCI) scores between the two imaging modalities.

Results:

68Ga-FAPI PET/CT showed higher sensitivity for detecting recurrence (93 % vs. 79 %); lymph node metastasis (89 % vs. 78 %), particularly peritoneal lymph node metastasis (92 % vs. 63 %); and metastatic implantation on the intestinal wall (100 % vs. 25 %) compared to 18F-FDG PET/CT. However, 68Ga-FAPI PET/CT showed lower sensitivity for detecting bone metastasis (67 % vs. 100 %). The mean SUVmax values of peritoneal metastases and metastatic implantation on the intestinal wall were 4.28 ± 2.70 and 7.58 ± 1.66 for 18F-FDG PET/CT and 5.66 ± 1.97 and 6.70 ± 0.25 for 68Ga-FAPI PET/CT, respectively. Furthermore, 68Ga-FAPI PET/CT showed significantly higher TBR for peritoneal metastatic lesions (4.22 ± 1.47 vs. 1.41 ± 0.89, p < 0.0001) and metastatic implantation on the intestinal wall (5.63 ± 1.24 vs. 2.20 ± 0.5, p = 0.02) compared to 18F-FDG PET/CT. For the same patient, 68Ga-FAPI PET/CT yielded a more accurate PCI score and a greater area under the curve value for the receiver operating characteristic curve (p < 0.01) than 18F-FDG PET/CT.

Conclusion:

68Ga-FAPI PET/CT was superior to 18F-FDG PET/CT for detecting recurrence and peritoneal metastases. Hence, we propose the combination of these two modalities for better clinical diagnosis and management of patients with CRC.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article