Your browser doesn't support javascript.
loading
Feasibility of totally implantable venous access ports in the upper arm for patients with head and neck cancer in the modern era of chemotherapy.
Ikeda, Masakazu; Matsuzuka, Takashi; Kakamu, Takeyasu; Nakaegawa, Yuta; Kawase, Tomotaka; Saito, Yukiko; Kubota, Satoshi; Imaizumi, Mitsuyoshi; Murono, Shigeyuki.
Afiliação
  • Ikeda M; Department of Otolaryngology, Fukushima Medical University, Fukushima City, Japan.
  • Matsuzuka T; Department of Head and Neck Surgery and Otolaryngology, Asahi University Hospital, Gifu, Japan.
  • Kakamu T; Department of Hygiene and Preventive Medicine, School of Medicine, Fukushima Medical University, Fukushima City, Japan.
  • Nakaegawa Y; Department of Otolaryngology, Fukushima Medical University, Fukushima City, Japan.
  • Kawase T; Department of Otolaryngology, Fukushima Medical University, Fukushima City, Japan.
  • Saito Y; Department of Otolaryngology, Fukushima Medical University, Fukushima City, Japan.
  • Kubota S; Department of Otolaryngology, Fukushima Medical University, Fukushima City, Japan.
  • Imaizumi M; Department of Otolaryngology, Fukushima Medical University, Fukushima City, Japan.
  • Murono S; Department of Otolaryngology, Fukushima Medical University, Fukushima City, Japan.
J Vasc Access ; : 11297298241279623, 2024 Sep 26.
Article em En | MEDLINE | ID: mdl-39327697
ABSTRACT
BACKGROUNDS With recent developments in chemotherapy, the prognosis of head and neck cancer patients has been prolonged, and it is expected that totally implantable venous access devices will be developed for use as feasible and safe chemotherapy routes. We investigated the feasibility of implanting totally implantable venous access ports in the upper arms of head and neck cancer patients in this modern era of chemotherapy.

METHODS:

Relevant data of a cohort of 210 patients with head and neck cancer who had had totally implantable venous access devices implanted between January 2013 and December 2022 were investigated retrospectively. The totally implantable venous access ports were used for chemoradiotherapy, chemotherapy, radiotherapy, and palliative treatment. Adverse events related to totally implantable venous access devices were investigated and the associated variables subjected to statistical analysis.

RESULTS:

There were 22 (10.5%) adverse events, representing 0.201 adverse events per 1000 catheter days. Non-ultrasound-guided puncture (p = 0.015) and forearm implantation (p = 0.005) were associated with higher risk of adverse events according to univariate analysis. According to multiple logistic analysis, non-ultrasound-guided puncture was significantly associated with age and sex (OR = 2.89; 95% CI, 1.14, 7.36; p = 0.026).

CONCLUSION:

Peripherally implanted totally implantable venous access devices in the upper arm are feasible and safe for head and neck cancer patients. Ultrasound-guided implantation of totally implantable venous access ports into the upper arms of head and neck cancer patients may reduce the adverse event rate.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article