Your browser doesn't support javascript.
loading
Comparative Study of Mini-implants versus Standard Implants in Orthodontic Anchorage for Space Closure.
Sahoo, Sanjay Kumar; Chekka, Manjunath; Chawla, Riddhi; Nehal Naimatullah, Mohammed; Kumar Misra, K; Kandikatla, Pradeep; Prashant, M C.
Afiliação
  • Sahoo SK; Department of Periodontics, Kalinga Institute of Dental Sciences, KIIT Deemed to be University, Bhubaneswar, Odisha, India.
  • Chekka M; Professor and HOD, Department of Orthodontics and Dentofacial Orthopaedics, Tirumala Dental College, Bardipur, Nizamabad, Telengana, India.
  • Chawla R; School of Dentistry, Central Asian University, Tashkent, Uzbekistan.
  • Nehal Naimatullah M; Asian Institute of Advanced Dentistry, Santoshnagar, Hyderabad, Telengana, India.
  • Kumar Misra K; Department of Oral and Maxillofacial Surgery, Kalinga Institute of Dental Sciences, Campus 5, KIIT University, Bhubaneswar, Odisha, India.
  • Kandikatla P; Department of Orthodontics and Dentofacial Orthopaedics, Vishnu Dental College, Bhimavaram, Andhra Pradesh, India.
  • Prashant MC; Department of Oral and Maxillofacial Surgery, RKDF Dental College and Research Centre, Bhopal, Madhya Pradesh, India.
J Pharm Bioallied Sci ; 16(Suppl 3): S2458-S2460, 2024 Jul.
Article em En | MEDLINE | ID: mdl-39346410
ABSTRACT

Background:

In order to obtain satisfactory treatment outcomes, orthodontic space closure frequently requires trustworthy anchoring devices. Because they are easier to install and smaller than regular implants, mini-implants have become a viable option. The purpose of this study was to evaluate the effectiveness of regular implants versus mini-implants as orthodontic anchoring devices for closing gaps in a tertiary care context.

Methods:

A total of 100 patients who needed space closure were split into two groups at random and given regular implants (group B, n = 50) or mini-implants (group A, n = 50). The rate of space closure, anchoring loss, and patient pain were measured using visual analog scales as the primary end measures. Resonance frequency analysis was used to assess implant stability. Based on implant survival and the lack of peri-implant problems, success rates were calculated.

Findings:

Mini-implants showed much lower rates of patient pain (P < 0.001) and anchoring loss (P < 0.05) than normal implants; however, they did show comparable rates of space closure (P = 0.42). In addition, mini-implants had comparable success rates (P = 0.78) and greater implant stability (P < 0.01) when compared to normal implants.

Conclusion:

In conclusion, mini-implants have benefits in anchorage preservation, patient comfort, and implant stability over regular implants when used as orthodontic anchoring devices for space closure. They also offer equivalent effectiveness. These results provide credence to the use of mini-implants as practical substitutes in orthodontic practice.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article