Detection of respiratory mechanical dysfunction by forced random noise impedance parameters.
Am Rev Respir Dis
; 120(5): 1095-100, 1979 Nov.
Article
em En
| MEDLINE
| ID: mdl-507525
Respiratory mechanical parameters were computed from forced random noise impedance data in normal adults (group 1), asymptomatic smokers (group 2), and patients with obstructive pulmonary disease (group 3). Mean values for all derived parameters were significantly different (p less than 0.025) for group 3. Mean values of resonant frequency, the ratio of low-frequency (5 to 9 Hz) resistance to high-frequency resistance (15 to 19 Hz), and conductance normalized by height, were significantly different (p less than 0.05) between groups 1 and 2. This approach appears to yield respiratory mechanical parameters that are sensitive to mechanical alterations induced by early pulmonary disease. The rapid, noninvasive, and effort-independent nature of this approach make it especially useful for epidemiologic studies and for studies of "noncooperative" subjects.
Buscar no Google
Base de dados:
MEDLINE
Assunto principal:
Respiração
/
Sons Respiratórios
/
Pneumopatias Obstrutivas
Idioma:
En
Ano de publicação:
1979
Tipo de documento:
Article