Neutron beams from protons on beryllium.
Phys Med Biol ; 25(5): 887-92, 1980 Sep.
Article em En | MEDLINE | ID: mdl-6256782
ABSTRACT
Measurements of dose rate and penetration in water have been made for neutron beams produced by 30--75 MeV protons on beryllium. The effects of Polythene filters added on the target side of the collimator have also been studied. A neutron beam comparable with a photon beam from a 4--8 MeV linear accelerator can be produced with p/Be neutrons plus 5 cm Polythene filtrations, with protons in the range 50--75 MeV. This is a more economical method than use of the d/Be reaction.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Prótons / Geradores de Radionuclídeos / Berílio / Nêutrons Idioma: En Ano de publicação: 1980 Tipo de documento: Article