The centered T-loop--a new way of preactivation.
Am J Orthod Dentofacial Orthop
; 108(2): 149-53, 1995 Aug.
Article
em En
| MEDLINE
| ID: mdl-7625387
The force system of a prefabricated and preactivated T-loop used for reciprocal space closure was determined by simultaneously measuring the horizontal and vertical forces, as well as the moments using a computer controlled measuring apparatus. Interbracket distances of 21, 24, 27, and 30 mm were used to mimic typical clinical situations. At a loop activation of 7 mm, the anterior and posterior segments first underwent controlled tipping, then translation, and finally, root uprighting as the moment-to-force ratio increased with deactivation. After the loop has been deactivated to 4 mm, however, it should be exchanged to avoid root abutment.
Buscar no Google
Base de dados:
MEDLINE
Assunto principal:
Ortodontia Corretiva
/
Perda de Dente
/
Análise do Estresse Dentário
Idioma:
En
Ano de publicação:
1995
Tipo de documento:
Article