Your browser doesn't support javascript.
loading
Peripheral vascular occlusive disease: accuracy and reliability of time-of-flight MR angiography.
McCauley, T R; Monib, A; Dickey, K W; Clemett, J; Meier, G H; Egglin, T K; Gusberg, R J; Rosenblatt, M; Pollak, J S.
Afiliação
  • McCauley TR; Department of Diagnostic Radiology, Yale University School of Medicine, New Haven, CT 06510.
Radiology ; 192(2): 351-7, 1994 Aug.
Article em En | MEDLINE | ID: mdl-8029396
ABSTRACT

PURPOSE:

To determine the accuracy and reliability of magnetic resonance (MR) angiography for identification of stenosis and patent distal vessels in patients with peripheral vascular disease. MATERIALS AND

METHODS:

Two-dimensional time-of-flight MR angiography and conventional arteriography were performed in 22 patients. Four blinded radiologists independently graded multiple anatomic segments.

RESULTS:

MR angiography allowed detection of more patent vessel segments than did conventional arteriography. For detection of significant stenosis (> 75%), MR angiography had 43%-67% sensitivity and 74%-89% specificity. Discrepancies in detection of significant stenosis occurred in 39 segments for the most accurate reviewer; 27 of these discrepancies were avoidable.

CONCLUSION:

For detection of significant stenosis, MR angiography has low to moderate sensitivity and specificity; however, observer variability appears to be a major contributing factor to the discrepancies. Greater reviewer experience or techniques for improving reliability may improve the accuracy of MR angiography in peripheral vascular disease.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Arteriopatias Oclusivas / Imageamento por Ressonância Magnética / Perna (Membro) Idioma: En Ano de publicação: 1994 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Arteriopatias Oclusivas / Imageamento por Ressonância Magnética / Perna (Membro) Idioma: En Ano de publicação: 1994 Tipo de documento: Article