Your browser doesn't support javascript.
loading
[Detection of myocardial ischemia during dobutamine stress echocardiography. Correlation with coronary cineangiography]. / Detecção de isquemia miocárdica através de ecocardiografia de estresse com dobutamina. Correlação com cinecoronariografia.
Mathias Júnior, W; Doya, E H; Ribeiro, E E; Silva, L A; Gasques, A; Salvadori, R A; Duprat Filho, R.
Afiliação
  • Mathias Júnior W; Hospital Unicor, São Paulo.
Arq Bras Cardiol ; 60(4): 229-34, 1993 Apr.
Article em Pt | MEDLINE | ID: mdl-8311730
ABSTRACT

PURPOSE:

To detect myocardial ischemia during dobutamine stress echocardiography (DSE).

METHODS:

Two hundred and seventy one patients were studied; 63 (23%) underwent coronary angiography within a month of DSE. Angiograms were analyzed independently by 3 angiographers, and coronary lesions larger than 50% of luminal occlusion were considered likely to cause ischemia.

RESULTS:

The global sensitivity and specificity were 95% and 75% respectively, with 89% accuracy. Of 43 patients showing obstructive coronary artery disease, there were 2 false negatives. One of 5 false positives had ischemic cardiomyopathy and another a technically difficult exam. The symptoms and side effects in decreasing order of occurrence are as follows palpitation 46%; arrhythmia 24%; mild hypotension 24%; chest pain 8%; hypertension 5%; facial paresthesia 4%; chills 1.8%; nausea 1.8%; headache 1.4%; dyspnea 0.4% and severe hypotension 0.4%.

CONCLUSION:

Considering the results, the small number of complications and the feasibility, DSE seems to be a safe and promising method for detecting myocardial ischemia.