Your browser doesn't support javascript.
loading
[Forced oscillation technique in respiratory system studies. III. Compliance and airway resistance in children with lung fibrosis]. / Technika oscylacji wymuszonych (FOT) w badaniu ukladu oddechowego. III. Podatnosc i opór ukladu oddechowego u dzieci ze zwlóknieniem pluc.
Tomalak, W; Mazurek, H; Ciolek, G; Willim, G.
Afiliação
  • Tomalak W; Instytutu Gruzlicy i Chorób Pluc, Zespól Pediatryczny w Rabce.
Pneumonol Alergol Pol ; 63(11-12): 690-4, 1995.
Article em Pl | MEDLINE | ID: mdl-8616490
ABSTRACT
In patient with lung fibrosis we need to monitor lung compliance to evaluate the progress of the illness or efficacy of the treatment. This examination is not well tolerated and difficult to perform, especially in children. We compared classic measurements of static compliance of the lung and airway resistance with parameters derived from forced oscillations measurements--compliance and resistance of respiratory system. Correlation coefficients were respectively 0.85 for compliance and 0.70 for resistance. We conclude that it is possible to supplement classic measurements, especially in evaluating the dynamics of illness.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Fibrose Pulmonar / Testes de Função Respiratória / Resistência das Vias Respiratórias Idioma: Pl Ano de publicação: 1995 Tipo de documento: Article