Your browser doesn't support javascript.
loading
Effect of hemoglobin- and Perflubron-based oxygen carriers on common clinical laboratory tests.
Ma, Z; Monk, T G; Goodnough, L T; McClellan, A; Gawryl, M; Clark, T; Moreira, P; Keipert, P E; Scott, M G.
Afiliação
  • Ma Z; Department of Pathology, Washington University School of Medicine, St. Louis, MO, USA.
Clin Chem ; 43(9): 1732-7, 1997 Sep.
Article em En | MEDLINE | ID: mdl-9299968
ABSTRACT
Polymerized hemoglobin solutions (Hb-based oxygen carriers; HBOCs) and a second-generation perfluorocarbon (PFC) emulsion (Perflubron) are in clinical trials as temporary oxygen carriers ("blood substitutes"). Plasma and serum samples from patients receiving HBOCs look markedly red, whereas those from patients receiving PFC appear to be lipemic. Because hemolysis and lipemia are well-known interferents in many assays, we examined the effects of these substances on clinical chemistry, immunoassay, therapeutic drug, and coagulation tests. HBOC concentrations up to 50 g/L caused essentially no interference for Na, K, Cl, urea, total CO2, P, uric acid, Mg, creatinine, and glucose values determined by the Hitachi 747 or Vitros 750 analyzers (or both) or for immunoassays of lidocaine, N-acetylprocainamide, procainamide, digoxin, phenytoin, quinidine, or theophylline performed on the Abbott AxSym or TDx. Gentamycin and vancomycin assays on the AxSym exhibited a significant positive and negative interference, respectively. Immunoassays for TSH on the Abbott IMx and for troponin I on the Dade Stratus were unaffected by HBOC at this concentration. Tests for total protein, albumin, LDH, AST, ALT, GGT, amylase, lipase, and cholesterol were significantly affected to various extents at different HBOC concentrations on the Hitachi 747 and Vitros 750. The CK-MB assay on the Stratus exhibited a negative interference at 5 g/L HBOC. HBOC interference in coagulation tests was method-dependent-fibrometer-based methods on the BBL Fibro System were free from interference, but optical-based methods on the MLA 1000C exhibited interferences at 20 g/L HBOC. A 120 dilution of the PFC-based oxygen carrier (600 g/L) caused no interference on any of these chemistry or immunoassay tests except for amylase and ammonia on the Vitros 750 and plasma iron on the Hitachi 747.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Oxigênio / Análise Química do Sangue / Substitutos Sanguíneos / Hemoglobinas / Testes Diagnósticos de Rotina / Fluorocarbonos Idioma: En Ano de publicação: 1997 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Oxigênio / Análise Química do Sangue / Substitutos Sanguíneos / Hemoglobinas / Testes Diagnósticos de Rotina / Fluorocarbonos Idioma: En Ano de publicação: 1997 Tipo de documento: Article