Biocompatibility evaluation of polyamide hemofiltration.
Panichi, V; Bianchi, A M; Andreini, B; Casarosa, L; Migliori, M; De Pietro, S; Taccola, D; Giovannini, L; Palla, R.
Afiliação
  • Panichi V; Department of Internal Medicine, University of Pisa, Italy.
Int J Artif Organs ; 21(7): 408-13, 1998 Jul.
Article em En | MEDLINE | ID: mdl-9745996
ABSTRACT

INTRODUCTION:

Postdilution hemofiltration with a polyamide membrane is a renal replacement technique widely used, but very little information is available regarding the biocompatibility of this treatment. In this paper we report the results of an acute study of the biocompatibility of polyamide hemofiltration. PATIENTS AND

METHODS:

Complement activation such as C3a and C5a Des Arg (RIA), granulocyte degranulation like alpha 1 elastase intradialytic increase (ELISA) and the expression of high affinity membrane receptors for IL-2 (anti-TAC) were determined. Beta 2-microglobulin (RIA) intradialytic decrease, as well as its convective removal, was evaluated. The nature of protein layer adsorbed onto the polyamide membrane, at the end of the dialytic session was investigated with a new immunohistochemical technique. Cell-associated cytokine concentration (like IL-1 beta and IL-1Ra - ELISA) was determined on mononuclear cell lysates.

RESULTS:

A low degree of complement activation was detected with the polyamide membrane when data were adjusted for hemoconcentration and for 1 m2 of membrane surface area. An important convective removal not only of Beta 2-microglobulin (258+/-20 mg/session), but also of the activated anaphylatoxins (225+/-76 ng/ml for C3a and 22.5+/-4 ng/ml for C5a) was revealed. A marked deposition of all coagulation factors with no detectable amount of immunoglobulins and complement factors was revealed on the polyamide membrane at the end of the dialytic session. No intradialytic (for IL-1beta) (from 14. 1+/-3.0 to 13.5+/-2.9 pg/2.5 x 10(6) cell) and interdialytic (for IL-1Ra) (from 4572+/-1076 to 5408+/-615 pg/2.5 x 10(6) cell) cell-associated cytokine expression was induced by hemofiltration. DISCUSSION AND

CONCLUSION:

Polyamide hemofiltration is a highly biocompatible technique due to the use of a synthetic membrane with a sterile reinfusion fluid and the convective removal of the activated anaphylatoxins and Beta 2-microglobulin.