Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 42
Filter
Add more filters

Country/Region as subject
Publication year range
1.
J Foot Ankle Surg ; 59(4): 664-672, 2020.
Article in English | MEDLINE | ID: mdl-32600559

ABSTRACT

Osteoporosis and osteoarthritis are common pathological problems of the human bone tissue. There are some cases of pilon fractures associated with these 2 pathological conditions. In terms of treatment, for a normal and healthy bone with pilon fracture, the use of the Delta external fixator is a favorable option because it can allow early mobilization for patients and provide stability for the healing process. However, the stability of the external fixator differs when there is low bone stiffness, which has not been previously investigated. Therefore, this study was conducted to determine the stability of the external fixator to treat pilon fracture associated with osteoporosis and osteoarthritis, particularly to differentiate the stress distribution and micromovement of fracture fragment. Three-dimensional finite element models of the ankle and foot bones were reconstructed based on the computed tomography datasets. The bones consisted of 5 metatarsal, 3 cuneiform, and 1 each of cuboid, navicular, calcaneus, talus, fibula, and tibia bones. They were assigned with linear isotropic behavior. The ankle joint consisted of ligament and cartilage, and they were assigned with the use of linear links and the Mooney-Rivlin model, respectively. During simulation of the gait cycle, 70 N and 350 N were applied axially to the tibia bone to represent the swing and stance phases, respectively. The metatarsal and calcaneus bones were fixed to prevent any movement of the rigid body. The study found that the greatest von Mises stress value was observed at the pin-bone interface for the osteoporosis (108 MPa) model, followed by the osteoarthritis (87 MPa) and normal (44 MPa) models, during the stance phase. For micromovement, the osteoporosis model had the largest value at 0.26 mm, followed by the osteoarthritis (0.09 mm) and normal (0.03 mm) models. In conclusion, the greatest magnitudes of stress and micromovement were observed for the osteoporosis bone and extra care should be taken to treat pilon fracture associated with this pathological condition.


Subject(s)
Ankle Fractures , Tibial Fractures , External Fixators , Finite Element Analysis , Humans , Tibia , Tibial Fractures/diagnostic imaging , Tibial Fractures/surgery
2.
Anal Biochem ; 549: 72-79, 2018 05 15.
Article in English | MEDLINE | ID: mdl-29524380

ABSTRACT

Distinctive bioactivities possessed by luteolin (3', 4', 5, 7-tetrahydroxy-flavone) are advantageous for sundry practical applications. This paper reports the in vitro selection and characterization of single stranded-DNA (ssDNA) aptamers, specific for luteolin (LUT). 76-mer library containing 1015 randomized ssDNA were screened via systematic evolution of ligands by exponential enrichment (SELEX). The recovered ssDNA pool from the 8th round was amplified with unlabeled primers and cloned into PSTBlue-1 vector prior to sequencing. 22 of LUT-binding aptamer variants were further classified into one of the seven groups based on their N40 random sequence regions, wherein one representative from each group was characterized. The dissociation constant of aptamers designated as LUT#28, LUT#20 and LUT#3 was discerned to be 107, 214 and 109 nM, respectively with high binding affinity towards LUT. Prediction analysis of the secondary structure suggested discrete features with typical loop and stem motifs. Furthermore, LUT#3 displayed higher specificity with insignificant binding toward kaempferol and quercetin despite its structural and functional similarity compared to LUT#28 and LUT#20. Further LUT#3 can detect free luteolin within 0.2-1 mM in solution. It was suggested that LUT#3 aptamer were the most suitable for LUT recognition tool at laboratory scale based on the condition tested.


Subject(s)
Kaempferols/chemistry , Luteolin/chemistry , Quercetin/chemistry , SELEX Aptamer Technique/methods , Aptamers, Nucleotide/chemical synthesis , Aptamers, Nucleotide/chemistry
3.
Knee Surg Sports Traumatol Arthrosc ; 22(12): 3019-27, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25149643

ABSTRACT

PURPOSE: Reproducing the femoral rollback through specially designed mechanism in knee implants is required to achieve full knee function in total knee arthroplasty. Most contemporary implants use cam/post mechanism to replace the function of Posterior Cruciate Ligament. This study was aimed to determine the most appropriate cam and post designs to produce normal femoral rollback of the knee. METHODS: Three different cams (triangle, ellipse, and circle) and three different posts (straight, convex, concave) geometries were considered in this study and were analysed using kinematic analyses. Femoral rollback did not occur until reaching 50° of knee flexion. Beyond this angle, two of the nine combinations demonstrate poor knee flexion and were eliminated from the study. RESULTS: The combination of circle cam with concave post, straight post and convex post showed 15.6, 15.9 and 16.1 mm posterior translation of the femur, respectively. The use of ellipse cam with convex post and straight post demonstrated a 15.3 and 14.9 mm femoral rollback, whilst the combination of triangle cam with convex post and straight post showed 16.1 and 15.8 mm femoral rollback, respectively. CONCLUSION: The present study demonstrates that the use of circle cam and convex post created the best femoral rollback effect which in turn produces the highest amount of knee flexion. The findings of the study suggest that if the design is applied for knee implants, superior knee flexion may be possible for future patients. LEVEL OF EVIDENCE: IV.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Femur/surgery , Knee Joint/surgery , Knee Prosthesis , Prosthesis Design , Aged , Aged, 80 and over , Biomechanical Phenomena , Computer Simulation , Female , Femur/physiopathology , Humans , Imaging, Three-Dimensional , Knee Joint/physiopathology , Male , Range of Motion, Articular , Tibia/physiopathology , Tibia/surgery
4.
ScientificWorldJournal ; 2014: 294104, 2014.
Article in English | MEDLINE | ID: mdl-24977191

ABSTRACT

Well-defined image can assist user to identify region of interest during segmentation. However, complex medical image is usually characterized by poor tissue contrast and low background luminance. The contrast improvement can lift image visual quality, but the fundamental contrast enhancement methods often overlook the sudden jump problem. In this work, the proposed bihistogram Bezier curve contrast enhancement introduces the concept of "adequate contrast enhancement" to overcome sudden jump problem in knee magnetic resonance image. Since every image produces its own intensity distribution, the adequate contrast enhancement checks on the image's maximum intensity distortion and uses intensity discrepancy reduction to generate Bezier transform curve. The proposed method improves tissue contrast and preserves pertinent knee features without compromising natural image appearance. Besides, statistical results from Fisher's Least Significant Difference test and the Duncan test have consistently indicated that the proposed method outperforms fundamental contrast enhancement methods to exalt image visual quality. As the study is limited to relatively small image database, future works will include a larger dataset with osteoarthritic images to assess the clinical effectiveness of the proposed method to facilitate the image inspection.


Subject(s)
Algorithms , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Osteoarthritis, Knee/pathology , Data Interpretation, Statistical , Humans , Reproducibility of Results , Sensitivity and Specificity
5.
Sci Rep ; 14(1): 6842, 2024 03 21.
Article in English | MEDLINE | ID: mdl-38514731

ABSTRACT

Previous research has primarily focused on pre-processing parameters such as design, material selection, and printing techniques to improve the strength of 3D-printed prosthetic leg sockets. However, these methods fail to address the major challenges that arise post-printing, namely failures at the distal end of the socket and susceptibility to shear failure. Addressing this gap, the study aims to enhance the mechanical properties of 3D-printed prosthetic leg sockets through post-processing techniques. Fifteen PLA + prosthetic leg sockets are fabricated and reinforced with four materials: carbon fiber, carbon-Kevlar fiber, fiberglass, and cement. Mechanical and microstructural properties of the sockets are evaluated through axial compression testing and scanning electron microscopy (SEM). Results highlight superior attributes of cement-reinforced sockets, exhibiting significantly higher yield strength (up to 89.57% more than counterparts) and higher Young's modulus (up to 76.15% greater). SEM reveals correlations between microstructural properties and socket strength. These findings deepen the comprehension of 3D-printed prosthetic leg socket post-processing, presenting optimization prospects. Future research can focus on refining fabrication techniques, exploring alternative reinforcement materials, and investigating the long-term durability and functionality of post-processed 3D-printed prosthetic leg sockets.


Subject(s)
Artificial Limbs , Prosthesis Design , Prosthesis Implantation , Pressure , Carbon Fiber , Printing, Three-Dimensional
6.
Heliyon ; 10(4): e26660, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38404809

ABSTRACT

Previous works had successfully demonstrated the clinical effectiveness of unilateral external fixator in treating various types of fracture, ranging from the simple type, such as oblique and transverse fractures, to complex fractures. However, literature that investigated its biomechanical analyses to further justify its efficacy is limited. Therefore, this paper aimed to analyse the stability of unilateral external fixator for treating different types of fracture, including the simple oblique, AO32C3 comminuted, and 20 mm gap transverse fracture. These fractures were reconstructed at the distal diaphysis of the femoral bone and computationally analysed through the finite element method under the stance phase condition. Findings showed a decrease in the fixation stiffness in large gap fracture (645.2 Nmm-1 for oblique and comminuted, while 23.4 Nmm-1 for the gap fracture), which resulted in higher displacement, IFM and stress distribution at the pin bone interface. These unfavourable conditions could consequently increase the risk of delayed union, pin loosening and infection, as well as implant failure. Nevertheless, the stress observed on the fracture surfaces was relatively low and in controlled amount, indicating that bone unity is still allowable in all models. Briefly, the unilateral fixation may provide desirable results in smaller fracture gap, but its usage in larger gap fracture might be alarming. These findings could serve as a guide and insight for surgeons and researchers, especially on the biomechanical stability of fixation in different fracture types and how will it affect bone unity.

7.
J Foot Ankle Surg ; 52(4): 426-31, 2013.
Article in English | MEDLINE | ID: mdl-23623302

ABSTRACT

The trapezium shape of the talar dome limits the use of 2-dimensional plain radiography for morphometric assessment because only 2 of the 4 required parameters can be measured. We used computed tomography data to measure the 4 morphologic parameters of the trochlea tali: anterior width, posterior width, trochlea tali length, and angle of trapezium shape. A total of 99 subjects underwent computed tomography scanning, and the left and right talus bones were both virtually modeled in 3 dimensions. The 4 morphologic parameters were measured 3 times each to obtain the intraclass correlation, and analysis of variance was used to check for any significant differences between the repeated measurements. The average intraclass correlation coefficient for the measurements for 2 to 3 trials was 0.94 ± 0.04. Statistical analyses were performed on the data from all 198 talus bones using SAS software, comparing male and female and left and right bones. All 4 morphometric values were greater in the male group. No significant differences were found between the left and right talus bones. A strong positive correlation was observed between the trochlea tali length and the anterior width. The angle of trapezium shape showed no correlation with the other 3 parameters. The measurements were compared with the dimensions of the current talar components of 4 total ankle arthroplasty implants. However, most of them did not perfectly match the trapezium shape of the talus from our population. We successfully analyzed the trapezium shape of the trochlea tali using reliable virtual 3-dimensional measurements. Compared with other published reports, our study showed a relatively smaller dimension of the trochlea tali than the European counterparts.


Subject(s)
Imaging, Three-Dimensional/methods , Talus/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Biomechanical Phenomena , Female , Follow-Up Studies , Humans , Male , Talus/physiopathology , Young Adult
8.
Materials (Basel) ; 16(9)2023 Apr 22.
Article in English | MEDLINE | ID: mdl-37176180

ABSTRACT

Total hip arthroplasty (THA) is most likely one of the most successful surgical procedures in medicine. It is estimated that three in four patients live beyond the first post-operative year, so appropriate surgery is needed to alleviate an otherwise long-standing suboptimal functional level. However, research has shown that during a complete THA procedure, a solid hip implant inserted in the femur can damage the main arterial supply of the cortex and damage the medullary space, leading to cortical bone resorption. Therefore, this study aimed to design a porous hip implant with a focus on providing more space for better osteointegration, improving the medullary revascularisation and blood circulation of patients. Based on a review of the literature, a lightweight implant design was developed by applying topology optimisation and changing the materials of the implant. Gyroid and Voronoi lattice structures and a solid hip implant (as a control) were designed. In total, three designs of hip implants were constructed by using SolidWorks and nTopology software version 2.31. Point loads were applied at the x, y and z-axis to imitate the stance phase condition. The forces represented were x = 320 N, y = -170 N, and z = -2850 N. The materials that were used in this study were titanium alloys. All of the designs were then simulated by using Marc Mentat software version 2020 (MSC Software Corporation, Munich, Germany) via a finite element method. Analysis of the study on topology optimisation demonstrated that the Voronoi lattice structure yielded the lowest von Mises stress and displacement values, at 313.96 MPa and 1.50 mm, respectively, with titanium alloys as the materials. The results also indicate that porous hip implants have the potential to be implemented for hip implant replacement, whereby the mechanical integrity is still preserved. This result will not only help orthopaedic surgeons to justify the design choices, but could also provide new insights for future studies in biomechanics.

9.
ScientificWorldJournal ; 2012: 474851, 2012.
Article in English | MEDLINE | ID: mdl-22666129

ABSTRACT

Ultrahigh-molecular-weight polyethylene/high-density polyethylene (UHMWPE/HDPE) blends prepared using polyethylene glycol PEG as the processing aid and hydroxyapatite (HA) as the reinforcing filler were found to be highly processable using conventional melt blending technique. It was demonstrated that PEG reduced the melt viscosity of UHMWPE/HDPE blend significantly, thus improving the extrudability. The mechanical and bioactive properties were improved with incorporation of HA. Inclusion of HA from 10 to 50 phr resulted in a progressive increase in flexural strength and modulus of the composites. The strength increment is due to the improvement on surface contact between the irregular shape of HA and polymer matrix by formation of mechanical interlock. The HA particles were homogenously distributed even at higher percentage showed improvement in wetting ability between the polymer matrix and HA. The inclusion of HA enhanced the bioactivity properties of the composite by the formation of calcium phosphate (Ca-P) precipitates on the composite surface as proven from SEM and XRD analysis.


Subject(s)
Durapatite/chemistry , Polyethylene Glycols/chemistry , Polyethylenes/chemistry , Rheology , Biomechanical Phenomena , Microscopy, Electron, Scanning , Particle Size , Polyethylenes/pharmacology , Spectrometry, X-Ray Emission , X-Ray Diffraction
10.
Int J Artif Organs ; 45(2): 200-206, 2022 Feb.
Article in English | MEDLINE | ID: mdl-33645338

ABSTRACT

Glenoid conformity is one of the important aspects that could contribute to implant stability. However, the optimal conformity is still being debated among the researchers. Therefore, this study aims to analyze the stress distribution of the implant and cement in three types of conformity (conform, non-conform, and hybrid) in three load conditions (central, anterior, and posterior). Glenoid implant and cement were reconstructed using Solidwork software and a 3D model of scapula bone was done using MIMICS software. Constant load, 750 N, was applied at the central, anterior, and posterior region of the glenoid implant which represents average load for daily living activities for elder people, including, walking with a stick and standing up from a chair. The results showed that, during center load, an implant with dual conformity (hybrid) showed the best (Max Stress-3.93 MPa) and well-distributed stress as compared to other conformity (Non-conform-7.21 MPa, Conform-9.38 MPa). While, during eccentric load (anterior and posterior), high stress was located at the anterior and posterior region with respect to the load applied. Cement stress for non-conform and hybrid implant recorded less than 5 MPa, which indicates it had a very low risk to have cement microcracks, whilst, conform implant was exposed to microcrack of the cement. In conclusion, hybrid conformity showed a promising result that could compromise between conform and non-conform implant. However, further enhancement is required for hybrid implants when dealing with eccentric load (anterior and posterior).


Subject(s)
Bone Cements , Scapula , Aged , Finite Element Analysis , Humans , Prosthesis Design , Stress, Mechanical
11.
Injury ; 53(7): 2424-2436, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35641332

ABSTRACT

For anterior cruciate ligament reconstruction (ACL-R), one of the crucial aspects of treatment is the fixator selection that could provide initial graft fixation post-operatively. Literature on biomechanical stabilities of different sizes of fixators as femoral graft fixation is limited. Therefore, this study aims to analyse the influence of different diameters of cross-pins on the stability of graft fixations after ACL-R via finite element analysis (FEA). In the methodology, three-dimensional (3D) models of three different diameters of cross-pins were developed, of which anterior tibial loads (ATL) were applied onto the tibia. From the findings, the cross-pin with a smaller diameter (4 mm) provided optimum stability than larger diameter cross-pins, whereby it demonstrated acceptable stresses at the fixators (both cross-pin and interference screw) with a different percentage of 28%, while the stresses at the corresponding bones were favourable for osseointegration to occur. Besides, the strains of the knee joint with 4 mm diameter cross-pin were also superior in providing a good biomechanical environment for bone healing, while the recorded strain values at fixators were comparable with a larger diameter of cross-pins without being inferior in terms of deformation. To conclude, the cross-pin with 4 mm diameter depicted the best biomechanical aspects in graft fixation for ACL-R since it allows better assistance for the osseointegration process and can minimise the possibility of the breakage and migration of fixators. This study is not only useful for medical surgeons to justify their choices of pin diameter to treat patients, but also for researchers to conduct future studies.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament Reconstruction , Anterior Cruciate Ligament/surgery , Anterior Cruciate Ligament Injuries/surgery , Anterior Cruciate Ligament Reconstruction/methods , Biomechanical Phenomena , Bone Nails , Finite Element Analysis , Humans , Knee Joint/surgery , Tibia/surgery
12.
Am J Phys Med Rehabil ; 100(4): 337-344, 2021 04 01.
Article in English | MEDLINE | ID: mdl-33727516

ABSTRACT

BACKGROUND: Due to the pain caused by knee injuries, low-load resistance training with blood flow restriction (L-BFR) may be a potential adjuvant therapeutic tool in the rehabilitation of knee injuries. This review aimed to analyze the effectiveness of L-BFR training modality in knee rehabilitation. DESIGN: A meta-analysis was conducted to determine the potential impact of blood flow restriction on patients with knee injuries. PubMed, EBSCO, and Web of Science databases were searched for eligible studies from January 2000 until January 2020. The mean differences of the data were analyzed using Revman 5.3 software with a 95% confidence interval. RESULTS: Nine studies fulfilled the inclusion criteria. These studies involved 179 patients who received L-BFR, 96 patients who underwent high-load resistance training, and another 94 patients who underwent low-load resistance training. The analysis of pooled data showed that patients in both the L-BFR (standardized mean difference, 0.83 [0.53, 1.14], P < 0.01) and high-load resistance training (standardized mean difference, -0.09 [-0.43, 0.24], P = 0.58) groups experienced an increase in muscle strength after the training. In addition, pain score was significantly reduced in the L-BFR group compared with the other two groups (standardized mean difference, -0.61 [-1.19, -0.03], P = 0.04). CONCLUSIONS: Muscle strength increased after L-BFR and high-load resistance training compared with low-load resistance training. Furthermore, pain score was significantly reduced after L-BFR. Hence, L-BFR is a potential intervention to be applied in rehabilitation of knee injuries.


Subject(s)
Knee Injuries/rehabilitation , Muscle, Skeletal/blood supply , Pain Management/methods , Resistance Training/methods , Constriction , Female , Humans , Male , Pain Measurement , Randomized Controlled Trials as Topic , Regional Blood Flow , Tourniquets
13.
Injury ; 52(8): 2131-2141, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33745700

ABSTRACT

An external fixator is a promising medical device that could provide optimum stability and reduce the rate of complications in treating bone fracture during intervention period. It is noted that the biomechanics behaviour of device can be altered by introducing more features such as material suitability and additional components. Therefore, this study was conducted via finite element method to investigate the effects of additional hollow cylinder coated with external fixator screws in treating Type III pilon fracture. Finite element models which have been validated with experimental data were used to simulate stresses at the pin-bone interface and relative micromovement at interfragmentary fractures during swing (70 N load) and stance phases (350 N load). All bones and external fixators were assigned with isotropic material properties while the cartilages were simulated with hyper-elastic. For the hollow cylinder, polyethylene was assigned due to its properties which are equivalent to the bone. From the results, it is found that stresses at the pin-bone interface for the coated screws were reduced to 54% as compared to the conventional fixator. For the micromovement, there was no difference between both models, whereby the value was 0.03 mm. The results supported previously published literature, in which high stresses are unavoidable at the interface, fortunately, those stresses did not exceed the ultimate strength of bone, which is safe for treating patients. In conclusion, if patients are allowed to bear weight bearing, the external fixator with coated screws is a more favourable option to be fixed into the bone to avoid complications at the interface.


Subject(s)
Ankle Fractures , Tibial Fractures , Biomechanical Phenomena , Bone Screws , External Fixators , Humans , Tibial Fractures/surgery
14.
Med Biol Eng Comput ; 59(9): 1945-1960, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34392448

ABSTRACT

Complication rates of anterior cruciate ligament reconstruction (ACL-R) were reported to be around 15% although it is a common arthroscopic procedure with good outcomes. Breakage and migration of fixators are still possible even months after surgery. A fixator with optimum stability can minimise those two complications. Factors that affect the stability of a fixator are its configuration, material, and design. Thus, this paper aims to analyse the biomechanical effects of different types of fixators (cross-pin, interference screw, and cortical button) towards the stability of the knee joint after ACL-R. In this study, finite element modelling and analyses of a knee joint attached with double semitendinosus graft and fixators were carried out. Mimics and 3-Matic softwares were used in the development of the knee joint models. Meanwhile, the graft and fixators were designed by using SolidWorks software. Once the meshes of all models were finished in 3-Matic, simulation of the configurations was done using MSC Marc Mentat software. A 100-N anterior tibial load was applied onto the tibia to simulate the anterior drawer test. Based on the findings, cross-pin was found to have optimum stability in terms of stress and strain at the femoral fixation site for better treatment of ACL-R.


Subject(s)
Anterior Cruciate Ligament Reconstruction , Biomechanical Phenomena , Femur/surgery , Finite Element Analysis , Humans , Knee Joint/surgery , Tibia/surgery
15.
J Tissue Eng Regen Med ; 15(4): 322-335, 2021 04.
Article in English | MEDLINE | ID: mdl-33432773

ABSTRACT

The importance of bone scaffolds has increased many folds in the last few years; however, during bone implantation, bacterial infections compromise the implantation and tissue regeneration. This work is focused on this issue while not compromising on the properties of a scaffold for bone regeneration. Biocomposite scaffolds (BS) were fabricated via the freeze-drying technique. The samples were characterized for structural changes, surface morphology, porosity, and mechanical properties through spectroscopic (Fourier transform-infrared [FT-IR]), microscopic (scanning electron microscope [SEM]), X-ray (powder X-ray diffraction and energy-dispersive X-ray), and other analytical (Brunauer-Emmett-Teller, universal testing machine Instron) techniques. Antibacterial, cellular, and hemocompatibility assays were performed using standard protocols. FT-IR confirmed the interactions of all the components. SEM illustrated porous and interconnected porous morphology. The percentage porosity was in the range of 49.75%-67.28%, and the pore size was 215.65-470.87 µm. The pore size was perfect for cellular penetration. Thus, cells showed significant proliferation onto these scaffolds. X-ray studies confirmed the presence of nanohydroxyapatite and graphene oxide (GO). The cell viability was 85%-98% (BS1-BS3), which shows no significant toxicity of the biocomposite. Furthermore, the biocomposites exhibited better antibacterial activity, no effect on the blood clotting (normal in vitro blood clotting), and less than 5% hemolysis. The ultimate compression strength for the biocomposites increased from 4.05 to 7.94 with an increase in the GO content. These exciting results revealed that this material has the potential for possible application in bone tissue engineering.


Subject(s)
Durapatite/chemistry , Fracture Healing , Fractures, Bone/pathology , Graphite/chemistry , Nanoparticles/chemistry , Polyvinyl Alcohol/chemistry , Tissue Scaffolds/chemistry , Xylans/chemistry , Animals , Anti-Bacterial Agents/pharmacology , Blood Coagulation/drug effects , Cell Adhesion/drug effects , Cell Death/drug effects , Cell Shape/drug effects , Cell Survival/drug effects , Fracture Healing/drug effects , Microbial Sensitivity Tests , Porosity , Rats , Spectrometry, X-Ray Emission , Spectroscopy, Fourier Transform Infrared , Water , X-Ray Diffraction
17.
ACS Omega ; 6(6): 4335-4346, 2021 Feb 16.
Article in English | MEDLINE | ID: mdl-33623844

ABSTRACT

In bone tissue engineering, multifunctional composite materials are very challenging. Bone tissue engineering is an innovative technique to develop biocompatible scaffolds with suitable orthopedic applications with enhanced antibacterial and mechanical properties. This research introduces a polymeric nanocomposite scaffold based on arabinoxylan-co-acrylic acid, nano-hydroxyapatite (nHAp), nano-aluminum oxide (nAl2O3), and graphene oxide (GO) by free-radical polymerization for the development of porous scaffolds using the freeze-drying technique. These polymeric nanocomposite scaffolds were coated with silver (Ag) nanoparticles to improve antibacterial activities. Together, nHAp, nAl2O3, and GO enhance the multifunctional properties of materials, which regulate their physicochemical and biomechanical properties. Results revealed that the Ag-coated polymeric nanocomposite scaffolds had excellent antibacterial properties and better microstructural properties. Regulated morphological properties and maximal antibacterial inhibition zones were found in the porous scaffolds with the increasing amount of GO. Moreover, the nanosystem and the polymeric matrix have improved the compressive strength (18.89 MPa) and Young's modulus (198.61 MPa) of scaffolds upon increasing the amount of GO. The biological activities of the scaffolds were investigated against the mouse preosteoblast cell lines (MC3T3-E1) and increasing the quantities of GO helps cell adherence and proliferation. Therefore, our findings showed that these silver-coated polymeric nanocomposite scaffolds have the potential for engineering bone tissue.

18.
Comput Biol Med ; 127: 104062, 2020 12.
Article in English | MEDLINE | ID: mdl-33096298

ABSTRACT

External fixators have been widely used in treating open fractures and have produced excellent outcomes, as they could successfully heal bones. The stability of external fixators lies greatly in their construction. Factors that associated with the stability of the external fixators includes stress, displacement, and relative micromotion. Three-dimensional (3D) models of bone and external fixators were constructed by using 3D modelling software, namely Materialise and SolidWorks, respectively. Three different configurations of external fixators namely Model 1, Model 2, and Model 3 were analysed. Three load cases were simulated to assess the abovementioned factors at the bone, specifically at the fracture site and at the external fixator. Findings showed that the double-cross configuration (Model 3) was the most promising in axial, bending, and torsion load cases as compared to the other two configurations. The no-cross configuration (Model 1) had the highest risk of complication due to high stress, relative micromotion, and displacement in the bending and torsion load cases. On the other hand, the single-cross configuration (Model 2) had the highest risk of complication when applied with axial load. In conclusion, the double-cross locking construct (Model 3) showed the biggest potential to be a new option for medical surgeons in treating patients associated with bone fracture. This new double-cross locking construct showed superior biomechanical stability as compared to single-cross and no-cross configurations in the axial, bending, and torsion load cases.


Subject(s)
Tibia , Tibial Fractures , Biomechanical Phenomena , External Fixators , Finite Element Analysis , Humans , Tibia/surgery , Tibial Fractures/surgery
19.
Injury ; 51(11): 2474-2478, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32798038

ABSTRACT

In an open fracture, the external fixator is one of the definitive treatment options as it could provide the initial stabilisation of the fractured bone. Limited literature discussing on the biomechanical stability between unilateral, hybrid and Ilizarov configurations, principally in treating a femoral fracture. Thus, this study aims to analyse the biomechanical stability of different external fixators via the finite element method (FEM). The present study portrays that different configurations of fixators possess different biomechanical stability, hence leading to different healing rates and complication risks. For the methodology, three-dimensional models of three different external fixators were reconstructed where axial loads were applied on the proximal end of the femur, simulating the stance phase. From the results, the unilateral configuration provides better stability compared to the hybrid and Ilizarov, where it displaced the least with an average percentage difference of 50% for the fixator's frame and 23% for the bone. The unilateral configuration also produced the least interfragmentary movement (0.48 mm) as compared to hybrid (0.62 mm) and Ilizarov (0.61 mm) configurations. Besides, the strain and stress of the unilateral configuration were superior in terms of stability compared to the other two configurations. As a conclusion, the unilateral configuration had the best biomechanical stability as it was able to assist the bone healing process as well as minimising the risk of pin tract infection while treating a femoral fracture.


Subject(s)
External Fixators , Fractures, Bone , Biomechanical Phenomena , Finite Element Analysis , Humans
20.
RSC Adv ; 10(66): 40529-40542, 2020 11 02.
Article in English | MEDLINE | ID: mdl-35520852

ABSTRACT

The excellent biocompatible and osteogenesis characteristics of porous scaffolds play a vital role in bone regeneration. In this study, we have synthesized polymeric hybrid nanocomposites via free-radical polymerization from carrageenan/acrylic-acid/graphene/hydroxyapatite. Porous hybrid nanocomposite scaffolds were fabricated through a freeze-drying method to mimic the structural and chemical composition of natural bone. Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and water contact-angle studies were carried-out for functional groups, surface morphology and hydrophilicity of the materials, followed by biodegradation and swelling analysis. The cell viability, cell culture and proliferation were evaluated against mouse pre-osteoblast (MC3T3-E1) cell lines using neutral red dye assay. The cell adherence and proliferation studies were determined by SEM. Physical characterization including optimum porosity and pore size (49.75% and 0.41 × 103 µm2), mechanical properties (compression strength 8.87 MPa and elastic modulus 442.63 MPa), swelling (70.20% at 27 °C and 77.21% at 37 °C) and biodegradation (23.8%) were performed. The results indicated CG-g-AAc-3 with a high optical density and better cell viability. Hence, CG-g-AAc-3 was found to be more efficient for bone regeneration with potential applications in fractured bone regeneration.

SELECTION OF CITATIONS
SEARCH DETAIL