1.
Catheter Cardiovasc Interv ; 103(7): 1101-1110, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38532517

ABSTRACT

Structural valve deterioration after aortic root replacement (ARR) surgery may be treated by transcatheter valve-in-valve (ViV-TAVI) intervention. However, several technical challenges and outcomes are not well described. The aim of the present review was to analyze the outcomes of ViV-TAVI in deteriorated ARR. This review included studies reporting any form of transcatheter valvular intervention in patients with a previous ARR. All forms of ARR were considered, as long as the entire root was replaced. Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane library databases were searched until September 2023. Overall, 86 patients were included from 31 articles that met our inclusion criteria out of 741 potentially eligible studies. In the entire population, the mean time from ARR to reintervention was 11.0 years (range: 0.33-22). The most frequently performed techniques/grafts for ARR was homograft (67.4%) and the main indication for intervention was aortic regurgitation (69.7%). Twenty-three articles reported no postoperative complications. Six (7.0%) patients required permanent pacemaker implantation (PPI) after the ViV-TAVI procedure, and 4 (4.7%) patients had a second ViV-TAVI implant. There were three device migrations (3.5%) and 1 stroke (1.2%). Patients with previous ARR present a high surgical risk. ViV-TAVI can be considered in selected patients, despite unique technical challenges that need to be carefully addressed according to the characteristics of the previous surgery and on computed tomography analysis.


Subject(s)
Aortic Valve , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/etiology , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Cardiac Pacing, Artificial , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Prosthesis Failure , Recovery of Function , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
2.
Eur J Anaesthesiol ; 35(11): 825-830, 2018 11.
Article in English | MEDLINE | ID: mdl-29708906

ABSTRACT

BACKGROUND: Continuous monitoring of core temperature is essential during major surgery as a way of improving patient safety. Oesophageal probes or specific arterial catheters are invasive methods used in this setting. A new noninvasive device based on zero-heat-flux (ZHF) technique (SpotOn) seems promising but has been poorly investigated during rapid core temperature changes (RCTC). OBJECTIVE: To assess the accuracy of a SpotOn sensor vs. an oesophageal probe or specific arterial catheter during a slow change in core temperature of less than 1 °C within 30 min and RCTC ≥ 1 °C within 30 min. DESIGN: Prospective observational study. SETTING: Operating rooms at the University Hospital of Poitiers, France. PATIENTS: Fifty patients scheduled for major abdominal surgery under general anaesthesia were enrolled from June 2015 to March 2016. Data from 49 patients were finally analysed. Among these, 15 patients were treated with hyperthermic intraperitoneal chemotherapy. INTERVENTION: Each patient had a ZHF sensor placed on the skin surface of the forehead (TempZHF) and an oesophageal probe (TempEso) used as a reference method. Twenty-two patients also had a thermodilution arterial catheter (TempArt) placed in the axillary artery. MAIN OUTCOME MEASURES: Core temperature was continuously recorded from the three devices after induction of anaesthesia. Comparison of temperature measurements between methods was made using the Bland and Altman method during two separate periods according to the speed of core temperature changes. RESULTS: Compared with TempEso, bias and limits of agreement for TempZHF were 0.1 ±â€Š0.5 °C during slow core temperature changes periods and 0.6 ±â€Š1.8 °C during RCTC periods (P = 0.0002). Compared with TempArt, these values were -0.1 ±â€Š0.4 and 0.5 ±â€Š1.7 °C, respectively (P = 0.0039). The ZHF sensor was well tolerated. CONCLUSION: A SpotOn sensor using the ZHF method seems reliable for core temperature monitoring during abdominal surgery when variations in core temperature are slow rather than rapid. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT02869828.


Subject(s)
Catheterization, Peripheral/methods , Esophagus/physiology , Monitoring, Intraoperative/methods , Skin Temperature/physiology , Aged , Body Temperature/physiology , Catheterization, Peripheral/instrumentation , Female , Humans , Male , Middle Aged , Monitoring, Intraoperative/instrumentation , Prospective Studies , Thermodilution/instrumentation , Thermodilution/methods