Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 486
Filter
Add more filters

Publication year range
1.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38445836

ABSTRACT

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Subject(s)
Brugada Syndrome , Defibrillators, Implantable , Pacemaker, Artificial , Female , Humans , Male , Middle Aged , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/diagnosis , Brugada Syndrome/complications , Brugada Syndrome/diagnosis , Brugada Syndrome/therapy , Electrocardiography/methods , Electrocardiography, Ambulatory/methods , Adult
2.
Article in English | MEDLINE | ID: mdl-39135364

ABSTRACT

INTRODUCTION: Thermal atrial fibrillation (AF) ablation exerts an additive treatment effect on the cardiac autonomic nervous system (CANS). This effect is mainly reported during ablation of the right superior pulmonary vein (RSPV), modulating the right anterior ganglionated plexus (RAGP), which contains parasympathetic innervation to the sinoatrial node in the epicardial fat pad between RSPV and superior vena cava (SVC). However, a variable response to neuromodulation after ablation is observed, with little to no effect in some patients. Our objective was to assess clinical and anatomic predictors of thermal ablation-induced CANS changes, as assessed via variations in heart rate (HR) postablation. METHODS: Consecutive paroxysmal AF patients undergoing first-time PV isolation by the cryoballoon (CB) or radiofrequency balloon (RFB) within a 12-month time frame and with preprocedural cardiac computed tomography (CT), were evaluated. Preablation and 24-h postablation electrocardiograms in sinus rhythm were collected and analyzed to assess HR. Anatomic evaluation by CT included the measurement of the shortest distance between the SVC and RSPV ostium (RSPV-SVC distance). RESULTS: A total of 97 patients (CB, n = 50 vs. RFB, n = 47) were included, with similar baseline characteristics between both groups. A significant HR increase postablation (ΔHR ≥ 15 bpm) occurred in a total of 37 patients (38.1%), without difference in number of patients between both thermal ablation technologies (CB, 19 [51%]), RFB, 18 [49%]). Independent predictors for increased HR were RSPV-SVC distance (odds ratio [OR]: 0.49, CI: 0.34-0.71, p value < .001), and age (OR: 0.94, CI: 0.89-0.98, p value = .003). CONCLUSIONS: Thermal balloon-based PV isolation influences the CANS through its effect on the RAGP, especially in younger patients and patients with shorter RSPV-SVC distance.

3.
Europace ; 25(8)2023 08 25.
Article in English | MEDLINE | ID: mdl-37622577

ABSTRACT

In the early nineties, few years before the birth of Europace, the clinical and scientific world of familial arrhythmogenic conditions was revolutionized by the identification of the first disease-causing genes. The explosion of genetic studies over a 15-year period led to the discovery of major disease-causing genes in practically all channelopathies and cardiomyopathies, bringing insight into the pathophysiological mechanisms of these conditions. The birth of next generation sequencing allowed a further step forward and other significant genes, as CALM1-3 in channelopathies and FLN C and TTN in cardiomyopathies were identified. Genotype-phenotype studies allowed the implementation of the genetic results in diagnosis, risk stratification, and therapeutic management with a different level of evidence in different arrhythmogenic conditions. The influence of common genetic variants, i.e. SNPs, on disease manifestation was proved in mid-twenties, and in the last 10 years with the advent of genome-wide association studies performed in familial arrhythmogenic diseases, the concept of polygenic risk score has been consolidated. Now, we are at the start of another amazing phase, i.e. the initiation of first gene therapy clinical trials.


Subject(s)
Cardiomyopathies , Channelopathies , Humans , Channelopathies/diagnosis , Channelopathies/genetics , Channelopathies/therapy , Genome-Wide Association Study , Cardiomyopathies/diagnosis , Cardiomyopathies/genetics , Cardiomyopathies/therapy , Cognition , High-Throughput Nucleotide Sequencing
4.
Europace ; 25(3): 896-904, 2023 03 30.
Article in English | MEDLINE | ID: mdl-36738245

ABSTRACT

AIMS: The multielectrode radiofrequency balloon catheter (RFB) has been developed to achieve safe and effective pulmonary vein isolation (PVI) for atrial fibrillation (AF) ablation. This single-centre study aimed to evaluate the midterm clinical outcome and predictors of single-shot PVI with the novel RFB. METHODS AND RESULTS: All consecutive patients with symptomatic paroxysmal or persistent AF undergoing first-time PVI with the RFB were prospectively included. Clinical and procedural parameters were systematically collected. The primary safety endpoint was defined as any major periprocedural complications. The primary efficacy endpoint consisted of freedom from any atrial tachyarrhythmias (ATas) lasting >30 s during the follow-up after a 3-month blanking period. Persistent single-shot PVI was defined as PVI achieved with a single RFB application without acute reconnection. A total of 104 consecutive patients (mean age 64.3 ± 11.4 years, 56.7% males) were included. 15 patients (14.4%) presented with persistent AF. The procedure time was 59.0 min with a dwell time of 20.0 min. One major complication occurred in one patient. At a mean follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. ATas occurred in 14 patients, 11/69 patients (15.9%) with paroxysmal AF and 3/13 (23.1%) with persistent AF. The best cut-offs to predict persistent single-shot PVI were impedance drop >19.2 Ω [area under the receiver operator characteristic curve (AUC) 0.74] and temperature rise >11.1° C (AUC 0.77). CONCLUSION: In a large cohort of patients undergoing PVI with the RFB, the complication rate was 1%. At a mid-term follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. Specific cut-offs of impedance drop and temperature rise may be useful to predict persistent single-shot isolation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Male , Humans , Middle Aged , Aged , Female , Treatment Outcome , Follow-Up Studies , Prospective Studies , Pulmonary Veins/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Tachycardia/surgery , Catheters , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
5.
Europace ; 25(12)2023 12 06.
Article in English | MEDLINE | ID: mdl-38064697

ABSTRACT

AIMS: Catheter ablation (CA) is an established treatment for atrial fibrillation (AF). A computed tomography (CT) may be performed before ablation to evaluate the anatomy of pulmonary veins. The aim of this study is to investigate the prevalence of patients with coronary artery disease (CAD) detected by cardiac CT scan pre-ablation and to evaluate the impact of CAD and revascularization on outcomes after AF ablation. METHODS AND RESULTS: All consecutive patients with AF diagnosis, hospitalized at Universitair Ziekenhuis Brussel, Belgium, between 2015 and 2019, were prospectively screened for enrolment in the study. Inclusion criteria were (i) AF diagnosis, (ii) first procedure of AF ablation with cryoballoon CA, and (iii) contrast CT scan performed pre-ablation. A total of 576 consecutive patients were prospectively included and analysed in this study. At CT scan, 122 patients (21.2%) were diagnosed with CAD, of whom 41 patients (7.1%) with critical CAD. At survival analysis, critical CAD at CT scan was a predictor of atrial tachyarrhythmia (AT) recurrence during the follow-up, only in Cox univariate analysis [hazard ratio (HR) = 1.79] but was not an independent predictor in Cox multivariate analysis. At Cox multivariate analysis, independent predictors of AT recurrence were as follows: persistent AF (HR = 2.93) and left atrium volume index (HR = 1.04). CONCLUSION: In patients undergoing CT scan before AF ablation, critical CAD was diagnosed in 7.1% of patients. Coronary artery disease and revascularization were not independent predictors of recurrence; thus, in this patient population, AF ablation should not be denied and can be performed together with CAD treatment.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Coronary Artery Disease , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/epidemiology , Coronary Artery Disease/surgery , Treatment Outcome , Heart Atria , Catheter Ablation/adverse effects , Catheter Ablation/methods , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Recurrence
6.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-37246904

ABSTRACT

AIMS: Hybrid atrial fibrillation (AF) ablation is a promising approach in non-paroxysmal AF. The aim of this study is to assess the long-term outcomes of hybrid ablation in a large cohort of patients after both an initial and as a redo procedure. METHODS AND RESULTS: All consecutive patients undergoing hybrid AF ablation at UZ Brussel from 2010 to 2020 were retrospectively evaluated. Hybrid AF ablation was performed in a one-step procedure: (i) thoracoscopic ablation followed by (ii) endocardial mapping and eventual ablation. All patients received PVI and posterior wall isolation. Additional lesions were performed based on clinical indication and physician judgement. Primary endpoint was freedom from atrial tachyarrhythmias (ATas). A total of 120 consecutive patients were included, 85 patients (70.8%) underwent hybrid AF ablation as first procedure (non-paroxysmal AF 100%), 20 patients (16.7%) as second procedure (non-paroxysmal AF 30%), and 15 patients (12.5%) as third procedure (non-paroxysmal AF 33.3%). After a mean follow-up of 62.3 months ± 20.3, a total of 63 patients (52.5%) experienced ATas recurrence. Complications occurred in 12.5% of patients. There was no difference in ATas between patients undergoing hybrid as first vs. redo procedure (P = 0.53). Left atrial volume index and recurrence during blanking period were independent predictors of ATas recurrence. CONCLUSION: In a large cohort of patients undergoing hybrid AF ablation, the survival from ATas recurrence was 47.5% at ≈5 years follow-up. There was no difference in clinical outcomes between patients undergoing hybrid AF ablation as first procedure or as a redo.


Subject(s)
Ablation Techniques , Atrial Fibrillation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Follow-Up Studies , Heart Atria , Retrospective Studies , Tachycardia , Treatment Outcome
7.
Europace ; 26(1)2023 12 28.
Article in English | MEDLINE | ID: mdl-38155611

ABSTRACT

AIMS: A novel sinus node (SN) sparing hybrid ablation for inappropriate sinus node tachycardia (IST)/postural orthostatic tachycardia syndrome (POTS) has been demonstrated to be an effective and safe therapeutic option in patients with symptomatic drug-resistant IST/POTS. The aim of this study was to evaluate the long-term rate of redo procedures after hybrid IST ablation and procedural strategy, outcomes and safety of redo procedures. METHODS AND RESULTS: All consecutive patients from 2015 to 2023 were prospectively enrolled in the UZ Brussel monocentric IST/POTS registry. They were analysed if the following inclusion criteria were fulfilled: 1) diagnosis of IST or POTS, 2) symptomatic IST/POTS refractory or intolerant to drugs, and 3) hybrid SN sparing ablation performed. The primary endpoint was redo procedure. The primary safety endpoint was pacemaker (PM) implantation. A total of 220 patients undergone to hybrid IST ablation were included, 185 patients (84.1%) were treated for IST and 61 patients (27.7%) for POTS.After a follow-up of 73.3 ± 16.2 months, 34 patients (15.4%) underwent a redo. A total of 23 patients (67.6%) had a redo for IST recurrence and 11 patients (32.4%) for other arrhythmias. Pacemaker implantation was performed in 21 patients (9.5%). Nine patients (4.1%) had no redo procedure and experienced sick sinus syndrome requiring a PM. Twelve patients (5.4%) received a PM as a shared therapeutic choice combined with SN ablation procedure. CONCLUSION: In a large cohort of patients the long-term free survival from redo procedure after hybrid IST ablation was 84.6% with a low PM implantation rate.


Subject(s)
Catheter Ablation , Tachycardia, Sinus , Humans , Tachycardia, Sinus/diagnosis , Tachycardia, Sinus/surgery , Tachycardia, Sinus/drug therapy , Sinoatrial Node , Catheter Ablation/adverse effects , Catheter Ablation/methods , Heart Rate
8.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-37061847

ABSTRACT

AIMS: A pathogenic/likely pathogenic (P/LP) variant in SCN5A is found in 20-25% of patients with Brugada syndrome (BrS). However, the diagnostic yield and prognosis of gene panel testing in paediatric BrS is unclear. The aim of this study is to define the diagnostic yield and outcomes of SCN5A gene testing with ACMG variant classification in paediatric BrS patients compared with adults. METHODS AND RESULTS: All consecutive patients diagnosed with BrS, between 1992 and 2022, were prospectively enrolled in the UZ Brussel BrS registry. Inclusion criteria were: (i) BrS diagnosis; (ii) genetic analysis performed with a large gene panel; and (iii) classification of gene variants following ACMG guidelines. Paediatric patients were defined as ≤16 years of age. The primary endpoint was ventricular arrhythmias (VAs). A total of 500 BrS patients were included, with 63 paediatric patients and 437 adult patients. Among children with BrS, 29 patients (46%) had a P/LP variant (P+) in SCN5A and no variants were found in 34 (54%) patients (P-). After a mean follow-up of 125.9 months, 8 children (12.7%) experienced a VA, treated with implanted cardioverter defibrillator shock. At survival analysis, P- paediatric patients had higher VA-free survival during the follow-up, compared with P+ paediatric patients. P+ status was an independent predictor of VA. There was no difference in VA-free survival between paediatric and adult BrS patients for both P- and P+. CONCLUSION: In a large BrS cohort, the diagnostic yield for P/LP variants in the paediatric population is 46%. P+ children with BrS have a worse arrhythmic prognosis.


Subject(s)
Brugada Syndrome , Adult , Humans , Child , Brugada Syndrome/diagnosis , Brugada Syndrome/genetics , Brugada Syndrome/therapy , Genetic Testing , Arrhythmias, Cardiac/genetics , Electric Countershock , Prognosis , Electrocardiography/methods , NAV1.5 Voltage-Gated Sodium Channel/genetics
9.
Clin Auton Res ; 33(1): 51-62, 2023 02.
Article in English | MEDLINE | ID: mdl-36645559

ABSTRACT

PURPOSE: Drug-induced type I Brugada syndrome (BrS) is associated with a ventricular arrhythmia (VA) rate of 1 case per 100 person-years. This study aims to evaluate changes in electrocardiographic (ECG) parameters such as microvolt T wave alternans (mTWA) and heart rate variability (HRV) at baseline and during ajmaline testing for BrS diagnosis. METHODS: Consecutive patients diagnosed with BrS during ajmaline testing with 5-year follow-up were included in this study. For comparison, a negative ajmaline control group and an isoproterenol control group were also included. ECG recordings during ajmaline or isoproterenol test were divided in two timeframes from which ECG parameters were calculated: a 5-min baseline timeframe and a 5-min drug timeframe. RESULTS: A total of 308 patients with BrS were included, 22 (0.7%) of which suffered VAs during follow-up. One hundred patients were included in both isoproterenol and negative ajmaline control groups. At baseline, there was no difference in ECG parameters between control groups and patients with BrS, nor between BrS with and without VAs. During ajmaline testing, BrS with VAs presented longer QRS duration [159 ± 34 ms versus 138 (122-155) ms, p = 0.006], higher maximum mTWA [33.8 (14.0-114) µV versus 8.00 (3.67-28.2) µV, p = 0.001], and lower power in low frequency band [25.6 (5.8-53.8) ms2 versus 129.5 (52.7-286) ms2, p < 0.0001] when compared to BrS without VAs. CONCLUSIONS: Ajmaline induced important HRV changes similar to those observed during isoproterenol. Increased mTWA was observed only in patients with BrS. BrS with VAs during follow-up presented worse changes during ajmaline test, including lower LF power and higher maximum mTWA which were independent predictors of events.


Subject(s)
Ajmaline , Brugada Syndrome , Humans , Ajmaline/pharmacology , Brugada Syndrome/diagnosis , Heart Rate , Isoproterenol , Arrhythmias, Cardiac , Electrocardiography , Prognosis
10.
Heart Vessels ; 38(6): 757-763, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36607386

ABSTRACT

To evaluate coronary artery disease (CAD) with computed tomography coronary angiography (CTCA)-derived fractional flow reserve (FFR) in patients with atrial fibrillation (AF) requiring ablation. The study population consisted of 151 patients who underwent CTCA before AF ablation (AF group), and a control group of 151 patients from the outpatient clinic who underwent CTCA without any history of AF (non-AF group), matched for age, sex, BMI, and angina symptomatology. All study patients underwent CTCA with subdivision of coronary lesion type into severe (≥ 70% luminal narrowing), moderate (50% ≤ luminal narrowing < 70%), and mild stenosis (< 50% luminal narrowing). In patients with ≥ 1 moderate or severe stenosis, non-invasive FFR was calculated from CTCA (FFRCT). Baseline characteristics and CAD risk factors were similar between the 2 groups. During CTCA, 38% of the patients in the AF group were in ongoing atrial arrhythmia (either AF or regular atrial tachycardia). The number of patients with severe (10 (6.6%) vs 10 (6.6%), P = 1.00), moderate (14 (9.5%) vs 10 (6.7%), P = 0.4), and mild stenosis (43 (28.5%) vs 56 (37.1%), P = 0.11) was not significantly different between the 2 groups. Performance of FFRCT was feasible in 32/44 patients (73%), and failed in 27% of the patients (7 and 5 patients in the AF and non-AF group, respectively, P = 0.74). No difference was observed in the prevalence of hemodynamically significant stenosis (FFRCT ≤ 0.80) (15 (9.9%) vs 12 (7.9%), P = 0.85). Our study showed technical feasibility of CTCA in all patients of both groups, including the patients with AF as presenting rhythm. The FFRCT add-on analysis failed equally frequent in patients of the AF versus non-AF group. An equal rate of CAD was observed in the AF group and non-AF group, favoring the concept of shared associated risk factors for CAD and AF.


Subject(s)
Atrial Fibrillation , Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Constriction, Pathologic , Coronary Angiography/methods , Tomography, X-Ray Computed/methods , Computed Tomography Angiography/methods , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/surgery , Predictive Value of Tests , Coronary Vessels
11.
Indian Pacing Electrophysiol J ; 23(4): 99-107, 2023.
Article in English | MEDLINE | ID: mdl-36906176

ABSTRACT

INTRODUCTION: The ablation of ventricular tachycardia, including premature ventricular contractions, is an approved, albeit infrequent procedure in pediatric patients. Data are scarce regarding the outcomes of this procedure. The purpose of this study was to share a high-volume center experience and patient outcomes for catheter ablation of ventricular ectopy and ventricular tachycardia in pediatric population. METHODS: Data were retrieved from the institutional data bank. Outcomes over time were evaluated, and procedural details were compared. RESULTS: A total of 116 procedures were performed on 102 pediatric patients between July 2009 and May 2021 at the Rajaie Cardiovascular Medical and Research Center in Tehran, Iran. Ablation was not performed in 4 procedures (3.4%) due to high-risk substrates. Of the remaining 112 ablations performed, 99 (88.4%) were successful. However, one patient died due to a coronary complication. There were no significant differences observed in early ablation results based on patients' age, sex, cardiac anatomy, or ablation substrates (P > 0.05). Follow-up records were available for 80 procedures, and 13 (16.3%) of those experienced recurrence. During long-term follow-up, none of the variables mentioned above were statistically different between patients with or without arrhythmia recurrence. CONCLUSION: The overall success rate of pediatric ventricular arrhythmia ablation is favorable. We found no significant predictor for the procedural success rate concerning acute and late outcomes. Larger multicenter studies are needed to elucidate the predictors and outcomes of the procedure.

12.
Europace ; 24(5): 845-854, 2022 05 03.
Article in English | MEDLINE | ID: mdl-34499723

ABSTRACT

AIMS: Ajmaline challenge can unmask subcutaneous implantable cardioverter-defibrillator (S-ICD) screening failure in patients with Brugada syndrome (BrS) and non-diagnostic baseline electrocardiogram (ECG). The efficacy of the SMART Pass (SP) filter, a high-pass filter designed to reduce cardiac oversensing (while maintaining an appropriate sensing margin), has not yet been assessed in patients with BrS. The aim of this prospective multicentre study was to investigate the effect of the SP filter on dynamic Brugada ECG changes evoked by ajmaline and to assess its value in reducing S-ICD screening failure in patients with drug-induced Brugada ECGs. METHODS AND RESULTS: The S-ICD screening with conventional automated screening tool (AST) was performed during ajmaline challenge in subjects with suspected BrS. The S-ICD recordings were obtained before, during and after ajmaline administration and evaluated by the means of a simulation model that emulates the AST behaviour with and without SP filter. A patient was considered suitable for S-ICD if at least one sensing vector was acceptable in all tested postures. A sensing vector was considered acceptable in the presence of QRS amplitude >0.5 mV, QRS/T-wave ratio >3.5, and sense vector score >100. Of the 126 subjects (mean age: 42 ± 14 years, males: 61%, sensing vectors: 6786), 46 (36%) presented with an ajmaline-induced Brugada type 1 ECG. Up to 30% of subjects and 40% of vectors failed the screening during the appearance of Brugada type 1 ECG evoked by ajmaline. The S-ICD screening failure rate was not significantly reduced in patients with Brugada ECGs when SP filter was enabled (30% vs. 24%). Similarly, there was only a trend in reduction of vector-failure rate attributable to the SP filter (from 40% to 36%). The most frequent reason for screening failure was low QRS amplitude or low QRS/T-wave ratio. None of these patients was implanted with an S-ICD. CONCLUSION: Patients who pass the sensing screening during ajmaline can be considered good candidates for S-ICD implantation, while those who fail might be susceptible to sensing issues. Although there was a trend towards reduction of vector sensing failure rate when SP filter was enabled, the reduction in S-ICD screening failure in patients with Brugada ECGs did not reach statistical significance. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov Unique Identifier NCT04504591.


Subject(s)
Brugada Syndrome , Defibrillators, Implantable , Adult , Ajmaline/adverse effects , Arrhythmias, Cardiac , Brugada Syndrome/diagnosis , Brugada Syndrome/therapy , Electrocardiography/methods , Humans , Male , Middle Aged , Prospective Studies
13.
Pacing Clin Electrophysiol ; 45(5): 605-611, 2022 05.
Article in English | MEDLINE | ID: mdl-35352363

ABSTRACT

BACKGROUND: Left atrial posterior wall isolation (LAPWI) is often performed in addition to pulmonary vein isolation (PVI) in the setting of persistent atrial fibrillation (AF) ablation. The aim of this study was to evaluate the feasibility and safety of a new cryoballoon ablation system in achieving PVI + LAPWI isolation. METHODS: The study was a prospective, non-randomized, single center study. Forty consecutive patients, undergoing PVI + LAPWI with the novel POLARx™, were compared to 40 consecutive patients who underwent the same procedure with the established Arctic Front Advance PRO™. RESULTS: Acute isolation was achieved in all PVs in both groups and left posterior wall isolation (LAPWI) was achieved in 38 patients (95%) in the POLARx group and in 36 patients (90%) in Arctic Front group. Procedural outcomes were similar between both groups, except for lower temperatures during cryoenergy in the POLARx group, for both pulmonary vein isolation (PVI) and LAPWI. CONCLUSION: LAPWI + PVI with the novel POLARx™ Cryoballoon is feasible and safe; the results are comparable with the Arctic Front Advance PRO™ system.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Atrial Fibrillation/surgery , Cryosurgery/methods , Feasibility Studies , Humans , Prospective Studies , Pulmonary Veins/surgery , Recurrence , Technology , Treatment Outcome
14.
Ann Noninvasive Electrocardiol ; 27(2): e12917, 2022 03.
Article in English | MEDLINE | ID: mdl-34882891

ABSTRACT

BACKGROUND: Brugada syndrome (BrS) is somewhat a challenging diagnosis, due to its dynamic pattern. One of the aspects of this disease is a significant conduction disorder located in the right ventricular outflow tract (RVOT), which can be explained as a consequence of low expression of Connexin-43. This decreased conduction speed is responsible for the typical electrocardiographic pattern. Opposite leads located preferably in inferior leads of the electrocardiogram may show a deep and widened S wave associated with ascending ST segment depression. Holter monitoring electrocardiographic (ECG) aspects is still a new frontier of knowledge in BrS, especially in intermittent clinical presentations. METHODS: We describe, as an exploratory analysis, five case series of intermittent type 1 BrS to demonstrate the appearance of ascending ST segment depression and widening of the S wave, during 3-channel 24h-Holter monitoring (C1, C2 and C3) with bipolar leads. RESULTS: In the five cases described, the ST segment depression was observed mainly in C2, but in some cases also in C1 and C3. Only case 1 presented concomitant intermittent elevation of the ST segment in C1. All cases were intermittent. CONCLUSION: The recognition of an ECG pattern with ascending ST-segment depression and widening of the S wave in 3-channel Holter described in this case series should raise a suspicion of the BrS and suggests the counterpart of a dromotropic disturbance registered in the RVOT and/or reciprocal changes.


Subject(s)
Brugada Syndrome , Arrhythmias, Cardiac , Depression , Electrocardiography , Electrocardiography, Ambulatory , Humans
15.
Pacing Clin Electrophysiol ; 44(12): 2075-2083, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34773413

ABSTRACT

BACKGROUND: Pulmonary vein (PV) isolation is an established treatment for paroxysmal drug-refractory atrial fibrillation (AF). High parasympathetic tone and reconnection of PVs have demonstrated to be possible culprits of AF recurrence after ablation. Our aim was to investigate the association between parasympathetic tone and reconnected PVs in patients with paroxysmal AF. METHODS: Consecutive patients who underwent a redo catheter ablation procedure for atrial tachyarrhythmia recurrence by means of 3D electroanatomic mapping with documentation of presence or absence of PVs reconnection following an initial procedure of cryoballoon (CB) ablation for symptomatic drug-refractory paroxysmal AF were screened for the study. RESULTS: A total of 92 patients were included, of whom 50 (54.35%) were males. Reconnected PVs were found in 64 (69%) patients. PVs reconnection could be predicted by DC (C-statistic = .770), by SDNNI (C-statistic = .714) and by absolute VLF power (C-statistic = .722), while right-sided PVs reconnection could be better predicted by DC (C-statistic = .848) and by SDNNI (C-statistic = .761). In multivariate binary logistic regression analysis, a DC value ≥6.45 ms and an absolute VLF power value ≥160 ms2 were associated with three times and five times higher odds of PVs reconnection, respectively. On a vein-per-vein analysis, absolute VLF power ≥160 ms2 was associated with three times higher odds, while reaching of -40°C within 60 s was associated with three times lower odds of PVs reconnection. CONCLUSION: High parasympathetic tonus accurately predicts PVs reconnection. On a vein-per-vein analysis, parasympathetic markers along with biophysical parameters predicted PVs reconnection. On a case-by-case analysis, parasympathetic markers were the only predictors of PVs reconnection, thus being a robust PVs reconnection prediction tool.


Subject(s)
Atrial Fibrillation/surgery , Autonomic Nervous System/physiopathology , Cryosurgery/methods , Pulmonary Veins/surgery , Vagus Nerve/physiopathology , Adult , Epicardial Mapping , Female , Humans , Male , Middle Aged , Recurrence , Reoperation
16.
J Electrocardiol ; 66: 125-128, 2021.
Article in English | MEDLINE | ID: mdl-33906061

ABSTRACT

The outcome in the Brugada syndrome (BrS) is more benign in female than in male individuals. However, outcome could be adversely affected by sinus node dysfunction (SND). Long sinus pauses indicate an overlap between the phenotypes of BrS and SND. We present a 29-year-old woman with syncopal episodes at rest since adolescence.


Subject(s)
Brugada Syndrome , Adult , Brugada Syndrome/diagnosis , Bundle-Branch Block , Electrocardiography , Female , Humans , Male , Sick Sinus Syndrome , Syncope/diagnosis , Syncope/etiology
17.
J Cardiovasc Electrophysiol ; 31(1): 128-136, 2020 01.
Article in English | MEDLINE | ID: mdl-31749209

ABSTRACT

AIM: The aim of this study is to assess specific per-vein procedural predictors of pulmonary vein (PV) late reconnection in cryoballoon ablation (CbA) METHODS AND RESULTS: We enrolled 148 consecutive patients undergoing a redo procedure after a previous index CbA in our center. A reconnection in at least one PV was found in 80 patients (54.1%) and the most frequently reconnected PV was the right inferior pulmonary vein (RIPV). Overall, pulmonary vein reconnection (PVr) was associated with longer time to -40°C (Tt-40°C) (54.4 ± 21.7 vs 67.6 ± 27.6 seconds; P < .001), warmer nadir temperature (NT) (-49.7°C ± 5.4°C vs -46.5°C ± 5.8°C; P < .001) and temperature at 60 seconds (-41.8°C ± 4.5°C vs -39.8°C ± 4.2°C; P < .001). The performance of these predictors differed between the veins. In particular, a comparable behavior was observed for left superior pulmonary vein (LSPV) and right superior pulmonary vein (RSPV), where NT ≤ -48°C showed a sensibility and a specificity, respectively, of 62% and 65% and 71% and 72% in predicting durable PV isolation. For RIPV, NT ≤ -48°C showed a sensitivity of 74% but low specificity (53%). Tt -40°C less than 60 seconds showed good negative predictive values, respectively, 83.9% for LSPV, 94.9% for left inferior pulmonary vein (LIPV), 90.2% for RSPV, and 82.7% for RIPV. Previous predictors cannot be used for LIPV. CONCLUSIONS: Freezing behavior and reconnection rates differ significantly among the four PVs. Freezing temperature parameters strongly predict late PVr in superior PVs and are slightly different in RIPV but can be applied as well. LIPV freezing behavior is the most different. Its reconnection is uncommon even in the subset of worse freezing temperatures and specific CB predictors cannot be identified.


Subject(s)
Action Potentials , Atrial Fibrillation/surgery , Cryosurgery/instrumentation , Pulmonary Veins/surgery , Adult , Aged , Aged, 80 and over , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Cryosurgery/adverse effects , Female , Heart Rate , Humans , Male , Middle Aged , Operative Time , Pulmonary Veins/physiopathology , Recurrence , Reoperation , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
18.
J Cardiovasc Electrophysiol ; 31(3): 629-637, 2020 03.
Article in English | MEDLINE | ID: mdl-31943519

ABSTRACT

AIM: The aim of the study was to investigate the role of anatomical characteristics of the pulmonary veins (PVs) determining cooling kinetics during second-generation cryoballoon ablation (CbA). METHODS AND RESULTS: we enrolled all consecutive patients who underwent CbA for symptomatic atrial fibrillation in our center from January 2019 to March 2019. All patients had complete computed tomography scans of the heart before the ablation. Anatomical characteristics were tested for prediction of a nadir temperature (NT) ≤ -48°C. Significant differences were noted among PV max diameter (20.8 ± 2.8 vs 18.5 ± 2.5 mm; P < .001); PV minimum diameter (15.2 ± 3.0 vs 13.0 ± 3.1 mm; P < .001); PV area (268.1 ± 71.9 vs 206.2 ± 58.7 mm2 ; P < .001); PV ovality (1.4 ± 0.3 vs 1.5 ± 0.3; P = .005); and PV trunk length (27.4 ± 7.4 vs 21.3 ± 6.5 mm; P < .001). A scoring system was created by assigning one point each ranging from 0 (best anatomical combination) to 5. In the group with a score of 0, 94.0% of the CbA could reach a NT ≤ -48°C whereas with a score of 5, only 29.0% (P < .001). Left superior pulmonary vein with short trunk length and acute angle of PV branch was significantly associated with warmer NT (11.8% satisfactory CbA; P = .003). Regarding right inferior pulmonary vein, trunk length (P = .004), maximum diameter (P = .044), and transverse angle (P = .008) were independently associated with good NT. CONCLUSION: Anatomical PV features are associated with cooling kinetics and an anatomical score could predict lower NT during second-generation CbA. Specific characteristics were identified for inferior PV. Although heart imaging is not mandatory prior CbA, it can be a useful tool to predict cooling kinetics.


Subject(s)
Atrial Fibrillation/surgery , Cold Temperature , Cryosurgery , Pulmonary Veins/surgery , Aged , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/physiopathology , Cold Temperature/adverse effects , Computed Tomography Angiography , Cryosurgery/adverse effects , Female , Humans , Kinetics , Male , Middle Aged , Phlebography , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/physiopathology , Retrospective Studies , Treatment Outcome
19.
Anesthesiology ; 132(3): 440-451, 2020 03.
Article in English | MEDLINE | ID: mdl-31743136

ABSTRACT

BACKGROUND: Brugada Syndrome is an inherited arrhythmogenic disease, characterized by the typical coved type ST-segment elevation in the right precordial leads from V1 through V3. The BrugadaDrugs.org Advisory Board recommends avoiding administration of propofol in patients with Brugada Syndrome. Since prospective studies are lacking, it was the purpose of this study to assess the electrocardiographic effects of propofol and etomidate on the ST- and QRS-segments. In this trial, it was hypothesized that administration of propofol or etomidate in bolus for induction of anesthesia, in patients with Brugada Syndrome, do not clinically affect the ST- and QRS-segments and do not induce arrhythmias. METHODS: In this prospective, double-blinded trial, 98 patients with established Brugada syndrome were randomized to receive propofol (2 to 3 mg/kg) or etomidate (0.2 to 0.3 mg/kg) for induction of anesthesia. The primary endpoints were the changes of the ST- and QRS-segment, and the occurrence of new arrhythmias upon induction of anesthesia. RESULTS: The analysis included 80 patients: 43 were administered propofol and 37 etomidate. None of the patients had a ST elevation greater than or equal to 0.2 mV, one in each group had a ST elevation of 0.15 mV. An ST depression up to -0.15mV was observed eleven times with propofol and five with etomidate. A QRS-prolongation of 25% upon induction was seen in one patient with propofol and three with etomidate. This trial failed to establish any evidence to suggest that changes in either group differed, with most percentiles being zero (median [25th, 75th], 0 [0, 0] vs. 0 [0, 0]). Finally, no new arrhythmias occurred perioperatively in both groups. CONCLUSIONS: In this trial, there does not appear to be a significant difference in electrocardiographic changes in patients with Brugada syndrome when propofol versus etomidate were administered for induction of anesthesia. This study did not investigate electrocardiographic changes related to propofol used as an infusion for maintenance of anesthesia, so future studies would be warranted before conclusions about safety of propofol infusions in patients with Brugada syndrome can be determined.


Subject(s)
Anesthesia, General/methods , Anesthetics, Intravenous , Brugada Syndrome/physiopathology , Electrocardiography/drug effects , Etomidate , Propofol , Adolescent , Adult , Aged , Aged, 80 and over , Anesthesia, General/adverse effects , Anesthetics, Intravenous/adverse effects , Double-Blind Method , Etomidate/adverse effects , Female , Humans , Male , Middle Aged , Propofol/adverse effects , Prospective Studies , Young Adult
20.
Europace ; 22(11): 1653-1658, 2020 11 01.
Article in English | MEDLINE | ID: mdl-32830231

ABSTRACT

AIMS: To assess the value of high-density mapping (HDM) in revealing undetected incomplete pulmonary vein isolation (PVI) after the fourth-generation cryoballoon (CB4G) ablation compared to the previous cryoballoon's versions. METHODS AND RESULTS: Consecutive patients with paroxysmal or early-persistent atrial fibrillation (AF) undergoing CB ablation as the index procedure, assisted by HDM, were retrospectively included in this study. A total of 68 patients (52 males; mean age: 60 ± 12 years, 58 paroxysmal AF) were included, and a total of 272 veins were mapped. Fourth-generation cryoballoon with the new spiral mapping catheter (SMC) was used in 35 patients (51%). Time to PVI was determined in 102/132 (77%) and in 112/140 (80%) veins during second-generation cryoballoon/third-generation cryoballoon (CB2G/CB3G) and CB4G ablation, respectively (P = 0.66). There was a statistically significant difference in terms of discrepancy rate between the SMC and the mini-basket catheter in PV detection after CB4G and CB2G/CB3G ablation(1.4% vs. 7.6%; P = 0.01). A total of 57 patients (84%) remained free of symptomatic AF during a mean follow-up of 9.8 ± 4.6 months. CONCLUSION: High-density mapping after cryoballoon ablation using CB4G and the new SMC identifies incomplete PVI, not detected by the new SMC, in a significantly lower proportion of veins compared to HDM performed after the other generation CB ablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheters , Cryosurgery/adverse effects , Humans , Male , Middle Aged , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Recurrence , Retrospective Studies , Treatment Outcome