ABSTRACT
BACKGROUND: Low serum vitamin D concentrations have been reported in several autoimmune disorders. OBJECTIVE: To assess whether low serum vitamin D concentrations are related to disease activity of patients with systemic lupus erythematosus (SLE). METHODS: 378 patients from several European and Israeli cohorts were pooled and their disease activity was measured by two different methods: 278 patients had SLE disease activity-2000 (SLEDAI-2K) scores and 100 patients had European Consensus Lupus Activity Measurement (ECLAM) scores. In order to combine the two systems the scores were converted into standardised values (z-scores), enabling univariate summary statistics for the two variables (SLEDAI-2K and ECLAM). The commercial kit, LIAISON 25-OH vitamin D assay (310900-Diasorin) was used to measure serum concentration of 25-OH vitamin D in 378 patients with SLE. RESULTS: A significant negative correlation was demonstrated between the serum concentration of vitamin D and the standardised values (z-scores) of disease activity scores as measured by the SLEDAI-2K and ECLAM scales (Pearson's correlation coefficient r=-0.12, p=0.018). CONCLUSIONS: In a cohort of patients with SLE originating from Israel and Europe vitamin D serum concentrations were found to be inversely related to disease activity.
Subject(s)
Lupus Erythematosus, Systemic/complications , Vitamin D Deficiency/etiology , Vitamin D/therapeutic use , Adolescent , Adult , Aged , Female , Humans , Lupus Erythematosus, Systemic/blood , Male , Middle Aged , Retrospective Studies , Severity of Illness Index , Vitamin D/blood , Vitamin D Deficiency/blood , Vitamin D Deficiency/drug therapy , Young AdultABSTRACT
Several progesterone-AH Sepharose 4B matrices were prepared as biospecific adsorbents suitable for affinity chromatography to fractionate antibodies of different affinity and specificity from a polyclonal antiserum to progesterone-11 alpha-hemisuccinate-BSA. From an affinity column of progesterone-11 alpha-hemisuccinate-AH Sepharose 4B no antibodies can be eluted, even with glycine buffer (pH 2.6) and 30% of 2-methoxyethanol. The use of biospecific adsorbents, prepared by coupling with AH Sepharose 4B progesterone derivatives [5-pregnene-3,20-dione di(ethyleneacetal)-11 alpha-ol-11 alpha-hemisuccinate; 4-pregnene-11,20 beta-diol-3-one-11 alpha-hemisuccinate 20 beta-benzoate; progesterone-3-carboxymethyloxime] having a low cross-reactivity with the antiserum, makes the elution of various antibody fractions of variable affinity and specificity possible. 2-Methoxyethanol or N,N-dimethylformamide gradients, in acetate or TRIS buffer, were equally efficient for fractionating the antiprogesterone serum, while a decreasing pH gradient was less effective and eluted antibody fractions that were further separated into various binding components by a solvent gradient. Antibodies eluted from the affinity columns by an eluent containing a high solvent concentration have affinities higher than antibodies eluted at lower solvent concentration.