Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 42
Filter
1.
J Biomech Eng ; 143(6)2021 06 01.
Article in English | MEDLINE | ID: mdl-33590841

ABSTRACT

Bilateral cervical facet dislocation (BFD) with facet fracture (Fx) often causes tetraplegia but is rarely recreated experimentally, possibly due to a lack of muscle replication. Intervertebral axial compression (due to muscle activation) or distraction (due to inertial loading), when combined with excessive anterior translation, may influence interfacet contact or separation and the subsequent production of BFD with or without Fx. This paper presents a methodology to produce C6/C7 BFD+Fx using anterior shear motion superimposed with 300 N compression or 2.5 mm distraction. The effect of these superimposed axial conditions on six-axis loads, and C6 inferior facet deflections and surface strains, was assessed. Twelve motion segments (70 ± 13 yr) achieved 2.19 mm of supraphysiologic anterior shear without embedding failure (supraphysiologic shear analysis point; SSP), and BFD+Fx was produced in all five specimens that reached 20 mm of shear. Linear mixed-effects models (α = 0.05) assessed the effect of axial condition. At the SSP, the compressed specimens experienced higher axial forces, facet shear strains, and sagittal facet deflections, compared to the distracted group. Facet fractures had similar radiographic appearance to those that are observed clinically, suggesting that intervertebral anterior shear motion contributes to BFD+Fx.


Subject(s)
Zygapophyseal Joint
2.
J Biomech Eng ; 137(5): 054501, 2015 May.
Article in English | MEDLINE | ID: mdl-25646970

ABSTRACT

Polymethyl methacrylate (PMMA) and Wood's Metal are fixation media for biomechanical testing; however, the effect of each potting medium on the measured six degree-of-freedom (DOF) mechanical properties of human lumbar intervertebral discs is unknown. The first aim of this study was to compare the measured 6DOF elastic and viscoelastic properties of the disc when embedded in PMMA compared to repotting in Wood's Metal. The second aim was to compare the surface temperature of the disc when potted with PMMA and Wood's Metal. Six human lumbar functional spinal units (FSUs) were first potted in PMMA, and subjected to overnight preload in a saline bath at 37 °C followed by five haversine loading cycles at 0.1 Hz in each of 6DOF loading directions (compression, left/right lateral bending, flexion, extension, left/right axial rotation, anterior/posterior, and lateral shear). Each specimen was then repotted in Wood's Metal and subjected to a 2-h re-equilibrating preload followed by repeating the same 6DOF tests. Outcome measures of stiffness and phase angle were calculated from the final loading cycle in each DOF and were expressed as normalized percentages relative to PMMA (100%). Disc surface temperatures (anterior, left/right lateral) were measured during potting. Paired t-tests (with alpha adjusted for multiple DOF) were conducted to compare the differences in each outcome parameter between PMMA and Wood's Metal. No significant differences in stiffness or phase angle were found between PMMA and Wood's Metal. On average, the largest trending differences were found in the shear DOFs for both stiffness (approximately 35% greater for Wood's Metal compared to PMMA) and phase angle (approximately 15% greater for Wood's Metal). A significant difference in disc temperature was found at the anterior surface after potting with Wood's Metal compared to PMMA, which did not exceed 26 °C. Wood's Metal is linear elastic, stiffer than PMMA and may reduce measurement artifact of potting medium, particularly in the shear directions. Furthermore, it is easier to remove than PMMA, reuseable, and cost effective.


Subject(s)
Elasticity , Lumbar Vertebrae/physiology , Materials Testing/instrumentation , Range of Motion, Articular , Aged, 80 and over , Humans , Polymethyl Methacrylate , Temperature , Viscosity
3.
J Hand Surg Am ; 40(1): 81-9.e1, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25447001

ABSTRACT

PURPOSE: To assess carpal kinematics in various ranges of motion in 3 dimensions with respect to lunate morphology. METHODS: Eight cadaveric wrists (4 type I lunates, 4 type II lunates) were mounted into a customized platform that allowed controlled motion with 6 degrees of freedom. The wrists were moved through flexion-extension (15°-15°) and radioulnar deviation (RUD; 20°-20°). The relative motion of the radius, carpus, and third metacarpal were recorded using optical motion capture methods. RESULTS: Clear patterns of carpal motion were identified. Significantly greater motion occurred at the radiocarpal joint during flexion-extension of type I wrist than a type II wrist. The relative contributions of the midcarpal and radiocarpal articulations to movement of the wrist differed between the radial, the central, and the ulnar columns. During wrist flexion and extension, these contributions were determined by the lunate morphology, whereas during RUD, they were determined by the direction of wrist motion. The midcarpal articulations were relatively restricted during flexion and extension of a type II wrist. However, during RUD, the midcarpal joint of the central column became the dominant articulation. CONCLUSIONS: This study describes the effect of lunate morphology on 3-dimensional carpal kinematics during wrist flexion and extension. Despite the limited size of the motion arcs tested, the results represent an advance on the current understanding of this topic. CLINICAL RELEVANCE: Differences in carpal kinematics may explain the effect of lunate morphology on pathological changes within the carpus. Differences in carpal kinematics due to lunate morphology may have implications for the management of certain wrist conditions.


Subject(s)
Lunate Bone/diagnostic imaging , Wrist Joint/physiology , Aged , Aged, 80 and over , Biomechanical Phenomena , Cadaver , Carpal Bones/diagnostic imaging , Carpal Bones/physiology , Humans , Imaging, Three-Dimensional , Lunate Bone/physiology , Metacarpal Bones/diagnostic imaging , Metacarpal Bones/physiology , Radius/diagnostic imaging , Radius/physiology , Range of Motion, Articular , Tomography, X-Ray Computed , Wrist Joint/diagnostic imaging
4.
J Hand Surg Eur Vol ; : 17531934241274135, 2024 Sep 16.
Article in English | MEDLINE | ID: mdl-39283016

ABSTRACT

This study compares wrist motion, biomechanical behaviour and radiographic parameters before and after total wrist arthroplasty using a fourth-generation spherical articulation prosthesis. A total of 10 cadaveric specimens were assessed using a hexapod Stewart platform robot. After arthroplasty, there were significant increases in both stiffness and phase angle of wrist motion across all planes of motion assessed. In three specimens, a sudden increase in moment was observed on load/displacement curves. Radiographically, carpal height increased by 14%, and the centre of rotation was displaced 11.1 mm proximally, 4.6 mm dorsally and 3.9 mm radially. This stretched the musculotendinous units, tightening the joint, while increasing the moment arm of the wrist flexors and decreasing the moment arm of the extensors, potentially important in the development of postoperative flexion contractures. Possible alterations in technique and/or implant design are considered to assist surgeons in achieving optimal clinical and survivorship outcomes.

5.
JOR Spine ; 7(3): e1360, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39071861

ABSTRACT

Background: Facet fractures are frequently associated with clinically observed cervical facet dislocations (CFDs); however, to date there has only been one experimental study, using functional spinal units (FSUs), which has systematically produced CFD with concomitant facet fracture. The role of axial compression and distraction on the mechanical response of the cervical facets under intervertebral motions associated with CFD in FSUs has previously been shown. The same has not been demonstrated in multi-segment lower cervical spine specimens under flexion loading (postulated to be the local injury vector associated with CFD). Methods: This study investigated the mechanical response of the bilateral inferior C6 facets of thirteen C5-C7 specimens (67±13 yr, 6 male) during non-destructive constrained flexion, superimposed with each of five axial conditions: (1) 50 N compression (simulating weight of the head); (2-4) 300, 500, and 1000 N compression (simulating the spectrum of intervertebral compression resulting from neck muscle bracing prior to head-first impact and/or externally applied compressive forces); and, (5) 2 mm of C6/C7 distraction (simulating the intervertebral distraction present during inertial loading of the cervical spine by the weight of the head). Linear mixed-effects models (α = 0.05) assessed the effect of axial condition. Results: Increasing amounts of intervertebral compression superimposed on flexion rotations, resulted in increased facet surface strains (range of estimated mean difference relative to Neutral: maximum principal = 77 to 110 µÎµ, minimum principal = 126 to 293 µÎµ, maximum shear = 203 to 375 µÎµ) and angular deflection of the bilateral inferior C6 facets relative to the C6 vertebral body (range of estimated mean difference relative to Neutral = 0.59° to 1.47°). Conclusions: These findings suggest increased facet engagement and higher load transfer through the facet joint, and potentially a higher likelihood of facet fracture under the compressed axial conditions.

6.
J Orthop Res ; 2024 May 12.
Article in English | MEDLINE | ID: mdl-38735861

ABSTRACT

Knee arthroplasty technique is constantly evolving and the opportunity for surgeons to practice new techniques is currently highly dependent on the availability of cadaveric specimens requiring certified facilities. The high cost, limited supply, and heterogeneity of cadaveric specimens has increased the demand for synthetic training models, which are currently limited by a lack of biomechanical fidelity. Here, we aimed to design, manufacture, and experimentally validate a synthetic knee surgical training model which reproduces the flexion dependent varus-valgus (VV) and anterior-posterior (AP) mechanics of cadaveric knees, while maintaining anatomic accuracy. A probabilistic finite element modeling approach was employed to design physical models to exhibit passive cadaveric VV and AP mechanics. Seven synthetic models were manufactured and tested in a six-degree-of-freedom hexapod robot. Overall, the synthetic models exhibited cadaver-like VV and AP mechanics across a wide range of flexion angles with little variation between models. In the extended position, two models showed increased valgus rotation (<0.5°), and three models showed increased posterior tibial translation (<1.7 mm) when compared to the 95% confidence interval (CI) of cadaveric measurements. At full flexion, all models showed VV and AP mechanics within the 95% CI of cadaveric measurements. Given the repeatable mechanics exhibited, the knee models developed in this study can be used to reduce the current reliance on cadaveric specimens in surgical training.

7.
Acta Orthop Belg ; 79(1): 64-70, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23547518

ABSTRACT

Impaction bone grafting shows encouraging early results as a method of immediately restoring leg length, while allowing weight-bearing as tolerated, in the treatment of large segmental femoral defects after femoral shaft and metaphyseal non-unions. The operative technique followed is described in three consecutive cases and the effectiveness of impaction bone grafting for femoral non-unions with associated large segmental bone defects has been demonstrated. Between 80 and 120 cm3 of coarsely milled irradiated bone allograft was used to reconstruct the defects, which were contained in malleable metal mesh. All three patients were fully weight-bearing by three months postoperatively. At two years follow-up, plain radiographs demonstrated maintenance of reduction and healing in all three cases.


Subject(s)
Bone Transplantation/methods , Femoral Fractures/surgery , Fracture Fixation, Internal , Fractures, Ununited/surgery , Adult , Debridement , Female , Femoral Fractures/complications , Femoral Fractures/diagnostic imaging , Fractures, Ununited/complications , Fractures, Ununited/diagnostic imaging , Humans , Leg Length Inequality/etiology , Leg Length Inequality/surgery , Male , Tomography, X-Ray Computed , Treatment Failure , Weight-Bearing
8.
J Mech Behav Biomed Mater ; 124: 104817, 2021 12.
Article in English | MEDLINE | ID: mdl-34536802

ABSTRACT

In vitro real-time replication of three-dimensional, time-varying load profiles acting on human bones during physical activity can advance bone and implant testing protocols. This study aimed to develop a novel protocol for applying the three-dimensional, time-varying hip contact force while walking to a human femur specimen. The target force profile was obtained from the literature. A proximal femur from an elderly female donor was instrumented using ten rosette strain gages and tested using a custom-made hexapod robot. A load-control algorithm determined the robot position generating the target force at low frequency (0.0004 Hz). Five cycles of the robot position were played back at five intermediate frequencies up to real-time (0.04, 0.08, 0.16, 0.4, and 0.8 Hz). The hip reaction force, the length of the actuators (position), and cortical strains were compared. The error in the load-control force was 0.3 ± 4.2 N (mean ± SD). The last three force, position, and strain cycles varied by less than 1.1% for every frequency analyzed. Across frequencies, the force increased by 28% at 0.8 Hz as a logarithmic function of frequency (R2 = 0.98). The position and strain error linearly increased with frequency up to 0.4 Hz. The median position error and the interquartile range of the strain error reached 15% and 13% at 0.8 Hz. Changes of force and cortical strain at increasing frequencies were linearly related (R2 = 0.99). Therefore, the protocol developed can provide repeatable three-dimensional time-varying load profiles, although the comparison of the specimen deformation obtained across frequencies should be considered with care, particularly in the higher frequency range. This information supports the design of dynamic tests of bone and implants.


Subject(s)
Femur , Walking , Aged , Biomechanical Phenomena , Bone and Bones , Female , Humans , Stress, Mechanical
9.
JOR Spine ; 4(1): e1138, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33778410

ABSTRACT

Biomechanical testing methodologies for the spine have developed over the past 50 years. During that time, there have been several paradigm shifts with respect to techniques. These techniques evolved by incorporating state-of-the-art engineering principles, in vivo measurements, anatomical structure-function relationships, and the scientific method. Multiple parametric studies have focused on the effects that the experimental technique has on outcomes. As a result, testing methodologies have evolved, but there are no standard testing protocols, which makes the comparison of findings between experiments difficult and conclusions about in vivo performance challenging. In 2019, the international spine research community was surveyed to determine the consensus on spine biomechanical testing and if the consensus opinion was consistent with the scientific evidence. More than 80 responses to the survey were received. The findings of this survey confirmed that while some methods have been commonly adopted, not all are consistent with the scientific evidence. This review summarizes the scientific literature, the current consensus, and the authors' recommendations on best practices based on the compendium of available evidence.

10.
Acta Biomater ; 123: 208-221, 2021 03 15.
Article in English | MEDLINE | ID: mdl-33453409

ABSTRACT

Collagen fibers within the annulus fibrosus (AF) lamellae are unidirectionally aligned with alternating orientations between adjacent layers. AF constitutive models often combine two adjacent lamellae into a single equivalent layer containing two fiber networks with a crisscross pattern. Additionally, AF models overlook the inter-lamellar matrix (ILM) as well as elastic fiber networks in between lamellae. We developed a nonhomogenous micromechanical model as well as two coarser homogenous hyperelastic and microplane models of the human AF, and compared their performances against measurements (tissue level uniaxial and biaxial tests as well as whole disc experiments) and seven published hyperelastic models. The micromechanical model had a realistic non-homogenous distribution of collagen fiber networks within each lamella and elastic fiber network in the ILM. For small matrix linear moduli (<0.2 MPa), the ILM showed substantial anisotropy (>10%) due to the elastic fiber network. However, at moduli >0.2 MPa, the effects of the elastic fiber network on differences in stress-strain responses at different directions disappeared (<10%). Variations in sample geometry and boundary conditions (due to uncertainty) markedly affected stress-strain responses of the tissue in uniaxial and biaxial tests (up to 16 times). In tissue level tests, therefore, simulations should represent testing conditions (e.g., boundary conditions, specimen geometry, preloads) as closely as possible. Stress/strain fields estimated from the single equivalent layer approach (conventional method) yielded different results from those predicted by the anatomically more accurate apparoach (i.e., layerwise). In addition, in a disc under a compressive force (symmetric loading), asymmetric stress-strain distributions were computed when using a layerwise simulation. Although all developed and selected published AF models predicted gross compression-displacement responses of the whole disc within the range of measured data, some showed excessively stiff or compliant responses under tissue-level uniaxial/biaxial tests. This study emphasizes, when constructing and validating constitutive models of AF, the importance of the proper simulation of individual lamellae as distinct layers, and testing parameters (sample geometric dimensions/loading/boundary conditions).


Subject(s)
Annulus Fibrosus , Intervertebral Disc , Anisotropy , Biomechanical Phenomena , Humans , Models, Biological , Pressure , Stress, Mechanical
11.
Spine (Phila Pa 1976) ; 45(6): 357-367, 2020 Mar 15.
Article in English | MEDLINE | ID: mdl-31593056

ABSTRACT

STUDY DESIGN: A biomechanical analysis correlating internal disc strains and tissue damage during simulated repetitive lifting. OBJECTIVE: To understand the failure modes during simulated safe and unsafe repetitive lifting. SUMMARY OF BACKGROUND DATA: Repetitive lifting has been shown to lead to lumbar disc herniation (LDH). In vitro studies have developed a qualitative understanding of the effect of repetitive loading on LDH. However, no studies have measured internal disc strains and subsequently correlated these with disc damage. METHODS: Thirty human cadaver lumbar functional spinal units were subjected to an equivalent of 1 year of simulated repetitive lifting under safe and unsafe levels of compression, in combination with flexion (13-15°), and right axial rotation (2°) for 20,000 cycles or until failure. Safe or unsafe lifting were applied as a compressive load to mimic holding a 20 kg weight either close to, or at arm's length, from the body, respectively. Maximum shear strains (MSS) were measured, and disc damage scores were determined in nine regions from axial post-test magnetic resonance imaging (MRI) and macroscopic images. RESULTS: Twenty percent of specimens in the safe lifting group failed before 20,000 cycles due to endplate failure, compared with 67% in the unsafe group. Over half of the specimens in the safe lifting group failed via either disc protrusion or LDH, compared with only 20% via protrusion in the unsafe group. Significant positive correlations were found between MRI and macroscopic damage scores in all regions (rs > 0.385, P < 0.049). A significant positive correlation was observed in the left lateral region for MSS versus macroscopic damage score (rs = 0.486, P < 0.037) and MSS versus failure mode (rs = 0.724, P = 0.018, only specimens with disc failure). Pfirrmann Grade 3 discs were strongly associated with subsequent LDH (P = 0.003). CONCLUSION: Increased shear strains were observed in the contralateral side to the applied rotation as disc injury progressed from protrusion to LDH. Larger compressive loads applied to simulate unsafe lifting led to frequent early failure of the endplate, however, smaller compressive loads at similar flexion angles applied under safe lifting led to more loading cycles before failure, where the site of failure was more likely to be the disc. Our study demonstrated that unsafe lifting leads to greater risk of injury compared with safe lifting, and LDH and disc protrusion were more common in the posterior/posterolateral regions. LEVEL OF EVIDENCE: N/A.


Subject(s)
Biomechanical Phenomena/physiology , Intervertebral Disc Degeneration/diagnostic imaging , Intervertebral Disc Displacement/diagnostic imaging , Intervertebral Disc/diagnostic imaging , Lifting/adverse effects , Adult , Aged , Cadaver , Female , Humans , Intervertebral Disc/pathology , Intervertebral Disc Degeneration/etiology , Intervertebral Disc Displacement/etiology , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/pathology , Magnetic Resonance Imaging/methods , Male , Middle Aged , Pressure/adverse effects , Range of Motion, Articular/physiology , Rotation/adverse effects , Weight-Bearing/physiology
12.
PLoS One ; 14(11): e0224432, 2019.
Article in English | MEDLINE | ID: mdl-31738770

ABSTRACT

Increases in the number of shark bites, along with increased media attention on shark-human interactions has led to growing interest in preventing injuries from shark bites through the use of personal mitigation measures. The leading cause of fatality from shark bite victims is blood loss; thus reducing haemorrhaging may provide additional time for a shark bite victim to be attended to by emergency services. Despite previous shark-proof suits being bulky and cumbersome, new technological advances in fabric has allowed the development of lightweight alternatives that can be incorporated onto traditional wetsuits. The ability for these fabrics to withstand shark bites has not been scientifically tested. In this report, we compared two types of recently developed protective fabrics that incorporated ultra-high molecular weight polyethylene (UHMWPE) fibre onto neoprene (SharkStop and ActionTX) and compared them to standard neoprene alternatives. We tested nine different fabric variants using three different tests, laboratory-based puncture and laceration tests, along with field-based trials involving white sharks Carcharodon carcharias. Field-based trials consisted of measuring C. carcharias bite force and quantifying damages to the new fabrics following a bite from 3-4 m total length C. carcharias. We found that SharkStop and ActionTX fabric variants were more resistant to puncture, laceration, and bites from C. carcharias. More force was required to puncture the new fabrics compared to control fabrics (laboratory-based tests), and cuts made to the new fabrics were smaller and shallower than those on standard neoprene for both types of test, i.e. laboratory and field tests. Our results showed that UHMWPE fibre increased the resistance of neoprene to shark bites. Although the use of UHMWPE fibre (e.g. SharkStop and ActionTX) may therefore reduce blood loss resulting from a shark bite, research is needed to assess if the reduction in damages to the fabrics extends to human tissues and decreased injuries.


Subject(s)
Bites and Stings/prevention & control , Lacerations/prevention & control , Protective Clothing , Sharks , Textiles , Animals , Bites and Stings/etiology , Humans , Lacerations/etiology , Materials Testing , Polyethylenes , Tooth
13.
J Biomech ; 83: 205-213, 2019 01 23.
Article in English | MEDLINE | ID: mdl-30554817

ABSTRACT

The subaxial cervical facets are important load-bearing structures, yet little is known about their mechanical response during physiological or traumatic intervertebral motion. Facet loading likely increases when intervertebral motions are superimposed with axial compression forces, increasing the risk of facet fracture. The aim of this study was to measure the mechanical response of the facets when intervertebral axial compression or distraction is superimposed on constrained, non-destructive shear, bending and rotation motions. Twelve C6/C7 motion segments (70 ±â€¯13 yr, nine male) were subjected to constrained quasi-static anterior shear (1 mm), axial rotation (4°), flexion (10°), and lateral bending (5°) motions. Each motion was superimposed with three axial conditions: (1) 50 N compression; (2) 300 N compression (simulating neck muscle contraction); and, (3) 2.5 mm distraction. Angular deflections, and principal and shear surface strains, of the bilateral C6 inferior facets were calculated from motion-capture data and rosette strain gauges, respectively. Linear mixed-effects models (α = 0.05) assessed the effect of axial condition. Minimum principal and maximum shear strains were largest in the compressed condition for all motions except for maximum principal strains during axial rotation. For right axial rotation, maximum principal strains were larger for the contralateral facets, and minimum principal strains were larger for the left facets, regardless of axial condition. Sagittal deflections were largest in the compressed conditions during anterior shear and lateral bending motions, when adjusted for facet side.


Subject(s)
Cervical Vertebrae/physiology , Movement , Rotation , Aged , Biomechanical Phenomena , Female , Humans , Male , Pressure , Weight-Bearing
14.
JOR Spine ; 2(1): e1047, 2019 Mar.
Article in English | MEDLINE | ID: mdl-31463461

ABSTRACT

The kinematics of the intervertebral disc are defined by six degrees of freedom (DOF): three translations (Tz: axial compression, Tx: lateral shear, and Ty: anterior-posterior shear) and three rotations (Rz: torsion, Rx: flexion-extension, and Ry: lateral bending). There is some evidence that the six DOFs are mechanically coupled, such that loading in one DOF affects the mechanics of the other five "off-axis" DOFs, however, most studies have not controlled and/or measured all six DOFs simultaneously. Additionally, the relationships between disc geometry and disc mechanics are important for evaluation of data from different sized donor and patient discs. The objectives of this study were to quantify the mechanical behavior of the intervertebral disc in all six degrees of freedom (DOFs), measure the coupling between the applied motion in each DOF with the resulting off-axis motions, and test the hypothesis that disc geometry influences these mechanical behaviors. All off-axis displacements and rotations were significantly correlated with the applied DOF and were of similar magnitude as physiologically relevant motion, confirming that off-axis coupling is an important mechanical response. Interestingly, there were pairs of DOFs that were especially strongly coupled: lateral shear (Tx) and lateral bending (Ry), anterior-posterior shear (Ty) and flexion-extension (Rx), and compression (Tz) and torsion (Rz). Large off-axis shears may contribute to injury risk in bending and flexion. In addition, the disc responded to shear (Tx, Ty) and rotational loading (Rx, Ry, and Rz) by increasing in disc height in order to maintain the applied compressive load. Quantifying these mechanical behaviors across all six DOF are critical for designing and testing disc therapies, such as implants and tissue engineered constructs, and also for validating finite element models.

15.
Acta Biomater ; 77: 292-300, 2018 09 01.
Article in English | MEDLINE | ID: mdl-30017922

ABSTRACT

The mechanical role of elastic fibers in the inter-lamellar matrix (ILM) is unknown; however, it has been suggested that they play a role in providing structural integrity to the annulus fibrosus (AF). Therefore, the aim of this study was to measure the viscoelastic and failure properties of the elastic fiber network in the ILM of ovine discs under both tension and shear directions of loading. Utilizing a technique, isolated elastic fibers within the ILM from ovine discs were stretched to 40% of their initial length at three strain rates of 0.1% s-1 (slow), 1% s-1 (medium) and 10% s-1 (fast), followed by a ramp test to failure at 10% s-1. A significant strain-rate dependent response was found, particularly at the fastest rate for phase angle and normalized stiffness (p < 0.001). The elastic fibers in the ILM demonstrated a significantly higher capability for energy absorption at slow compared to medium and fast strain rates (p < 0.001). These finding suggests that the elastic fiber network of the ILM exhibits nonlinear elastic behavior. When tested to failure, a significantly higher normalized failure force was found in tension compared to shear loading (p = 0.011), which is consistent with the orthotropic structure of elastic fibers in the ILM. The results of this study confirmed the mechanical contribution of the elastic fiber network to the ILM and the structural integrity of the AF. This research serves as a foundation for future studies to investigate the relationship between degeneration and ILM mechanical properties. STATEMENT OF SIGNIFICANCE: The mechanical role of elastic fibres in the inter-lamellar matrix (ILM) of the disc is unknown. The viscoelastic and failure properties of the elastic fibre network in the ILM in both tension and shear directions of loading was measured for the first time. We found a strain-rate dependent response for the elastic fibres in the ILM. The elastic fibres in the ILM demonstrated a significantly higher capability for energy absorption at slow compared to medium and fast strain rates. When tested to failure, a significantly higher normalized failure force was found in tension compared to shear loading, which is consistent with the orthotropic structure of elastic fibres in the ILM.


Subject(s)
Annulus Fibrosus/physiology , Elastic Tissue/physiology , Animals , Biomechanical Phenomena , Elasticity , Shear Strength , Sheep , Stress, Mechanical , Tensile Strength , Viscosity
16.
Mater Sci Eng C Mater Biol Appl ; 93: 299-304, 2018 Dec 01.
Article in English | MEDLINE | ID: mdl-30274062

ABSTRACT

A simple and cost effective protocol for visualization and isolation of the elastic fibres network in the annulus fibrosus (AF) of the disc is explained, to provide other researchers a method that can be applied in disc ultra-structural analysis, biomechanical assessment of elastic fibre and tissue engineered scaffold fabrication. This protocol is developed based on simultaneous sonication and alkali digestion of tissue that eliminates all matrix constituents except for elastic fibres, which is applicable for different species including human. Thin samples harvested from ovine, bovine, porcine and human, which are commonly used in disc research, were exposed to 0.5 M sodium hydroxide solution along with sonication (25 kHz) in distilled water for defined periods of time at room temperature. Post heat treatment removed collagen fibres via the gelatinization process, for visualization of elastic fibres.


Subject(s)
Annulus Fibrosus/chemistry , Elastic Tissue/chemistry , Tissue Scaffolds/chemistry , Animals , Cattle , Humans , Sheep
17.
J Biomech ; 67: 24-31, 2018 01 23.
Article in English | MEDLINE | ID: mdl-29221904

ABSTRACT

Disc degeneration is a common medical affliction whose origins are not fully understood. An improved understanding of its underlying mechanisms could lead to the development of more effective treatments. The aim of this paper was to investigate the effect of (1) degeneration, (2) circumferential region and (3) strain rate on the microscale mechanical properties (toe region modulus, linear modulus, extensibility, phase angle) of individual fibre bundles in the anulus fibrosus lamellae of the human intervertebral disc. Healthy and degenerate fibre bundles excised from different circumferential regions in the outer anulus (posterolateral, lateral, anterolateral, anterior) were tensile tested at slow (0.1%/s), medium (1%/s) and fast (10%/s) strain rates using a micromechanical testing system. Our preliminary results showed that neither degeneration nor circumferential region significantly affected the fibre bundles' mechanical behaviour. However, when the fibre bundles were tested at higher strain rates, this resulted in significantly higher linear moduli and lower phase angles. These findings, compared with data from other studies investigating single and multiple lamellae sections, suggest that degeneration has minimal effect on outer anulus mechanics irrespective of structural level, and the inter- and intra-lamellar arrangement and continuity of the fibre bundles may influence the lamellae's regional behaviour and viscoelasticity.


Subject(s)
Annulus Fibrosus/physiology , Intervertebral Disc/physiology , Lumbar Vertebrae/physiology , Lumbosacral Region/physiology , Adolescent , Adult , Aged , Aged, 80 and over , Cadaver , Humans , Middle Aged , Stress, Mechanical , Tensile Strength , Viscosity , Young Adult
18.
J Biomech ; 72: 116-124, 2018 04 27.
Article in English | MEDLINE | ID: mdl-29627133

ABSTRACT

Traumatic cervical facet dislocation (CFD) is often associated with devastating spinal cord injury. Facet fractures commonly occur during CFD, yet quantitative measures of facet deflection, strain, stiffness and failure load have not been reported. The aim of this study was to determine the mechanical response of the subaxial cervical facets when loaded in directions thought to be associated with traumatic bilateral CFD - anterior shear and flexion. Thirty-one functional spinal units (6 × C2/3, C3/4, C4/5, and C6/7, 7 × C5/6) were dissected from fourteen human cadaver cervical spines (mean donor age 69 years, range 48-92; eight male). Loading was applied to the inferior facets of the inferior vertebra to simulate the in vivo inter-facet loading experienced during supraphysiologic anterior shear and flexion motion. Specimens were subjected to three cycles of sub-failure loading (10-100 N, 1 mm/s) in each direction, before being failed in a randomly assigned direction (10 mm/s). Facet deflection, surface strains, stiffness, and failure load were measured. Linear mixed-effects models (α = 0.05; random effect of cadaver) accounted for variations in specimen geometry and bone density. Specimen-specific parameters were significantly associated with most outcome measures. Facet stiffness and failure load were significantly greater in the simulated flexion loading direction, and deflection and surface strains were higher in anterior shear at the non-destructive analysis point (47 N applied load). The sub-failure strains and stiffness responses differed between the upper and lower subaxial cervical regions. Failure occurred through the facet tip during anterior shear loading, while failure through the pedicles was most common in flexion.


Subject(s)
Cervical Vertebrae/physiology , Spinal Cord Injuries/physiopathology , Aged , Aged, 80 and over , Biomechanical Phenomena , Bone Density , Cadaver , Female , Humans , Male , Middle Aged , Range of Motion, Articular , Stress, Mechanical
19.
Ann Biomed Eng ; 46(9): 1280-1291, 2018 Sep.
Article in English | MEDLINE | ID: mdl-29786777

ABSTRACT

While microstructural observations have improved our understanding of possible pathways of herniation progression, no studies have measured the mechanical failure properties of the inter-lamellar matrix (ILM), nor of the adjacent lamellae during progression to herniation. The aim of this study was to employ multiscale, biomechanical and microstructural techniques to evaluate the effects of progressive induced herniation on the ILM and lamellae in control, pre-herniated and herniated discs (N = 7), using 2 year-old ovine spines. Pre-herniated and herniated (experimental) groups were subjected to macroscopic compression while held in flexion (13°), before micro-mechanical testing. Micro-tensile testing of the ILM and the lamella from anterior and posterolateral regions was performed in radial and circumferential directions to measure failure stress, modulus, and toughness in all three groups. The failure stress of the ILM was significantly lower for both experimental groups compared to control in each of radial and circumferential loading directions in the posterolateral region (p < 0.032). Within each experimental group in both loading directions, the ILM failure stress was significantly lower by 36% (pre-herniation), and 59% (herniation), compared to the lamella (p < 0.029). In pre-herniated compared to control discs, microstructural imaging revealed significant tissue stretching and change in orientation (p < 0.003), resulting in a loss of distinction between respective lamellae and ILM boundaries.


Subject(s)
Intervertebral Disc Displacement/physiopathology , Lumbar Vertebrae/physiology , Animals , Biomechanical Phenomena , Sheep , Stress, Mechanical
20.
J Biomech ; 70: 59-66, 2018 03 21.
Article in English | MEDLINE | ID: mdl-28951045

ABSTRACT

The complexity of multi-axis spine testing often makes it challenging to compare results from different studies. The aim of this work was to develop and implement a standardized testing protocol across three six-axis spine systems, compare them, and provide stiffness and phase angle limits against which other test systems can be compared. Standardized synthetic lumbar specimens (n=5), comprising three springs embedded in polymer at each end, were tested on each system using pure moments in flexion-extension, lateral bending, and axial rotation. Tests were performed using sine and triangle waves with an amplitude of 8Nm, a frequency of 0.1Hz, and with axial preloads of 0 and 500N. The stiffness, phase angle, and R2 value of the moment against rotation in the principal axis were calculated at the center of each specimen. The tracking error was adopted asa measure of each test system to minimize non-principal loads, defined as the root mean squared difference between actual and target loads. All three test systems demonstrated similar stiffnesses, with small (<14%) but significant differences in 4 of 12 tests. More variability was observed in the phase angle between the principal axis moment and rotation, with significant differences in 10 of 12 tests. Stiffness and phase angle limits were calculated based on the 95% confidence intervals from all three systems. These recommendations can be used with the standard specimen and testing protocol by other research institutions to ensure equivalence of different spine systems, increasing the ability to compare in vitro spine studies.


Subject(s)
Lumbar Vertebrae/physiology , Biomechanical Phenomena , Materials Testing/methods , Rotation
SELECTION OF CITATIONS
SEARCH DETAIL