Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 48
Filter
Add more filters

Publication year range
1.
Phys Rev Lett ; 112(11): 115001, 2014 Mar 21.
Article in English | MEDLINE | ID: mdl-24702380

ABSTRACT

With fusion device performance hinging on the edge pedestal pressure, it is imperative to experimentally understand the physical mechanism dictating the pedestal characteristics and to validate and improve pedestal predictive models. This Letter reports direct evidence of density and magnetic fluctuations showing the stiff onset of an edge instability leading to the saturation of the pedestal on the Alcator C-Mod tokamak. Edge stability analyses indicate that the pedestal is unstable to both ballooning mode and kinetic ballooning mode in agreement with observations.

2.
Rev Sci Instrum ; 95(8)2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39166910

ABSTRACT

A powerful and flexible hard x-ray (HXR) camera has been recently installed and tested on the WEST tokamak (CEA, France) in collaboration with the Princeton Plasma Physics Laboratory. The diagnostic is a pinhole camera fielded with a 2D pixel detector equipped with a 1 mm thick CdTe sensor. The novelty of this diagnostic technique is the detector's capability of adjusting the threshold energy at the pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space, energy, and time resolved x-ray measurements. The novel camera has been used to measure the core radiation from non-Maxwellian (fast) electrons accelerated by Lower Hybrid (LH) waves and also the beam-target emission of tungsten in the divertor region produced by fast electron losses interacting with the target. In addition, anisotropic hard x-ray emission has been detected for the first time at the WEST core and edge plasma, with opposite toroidal intensity trends. Experimental vertical and toroidal HXR profiles have been successfully reproduced with the LH code LUKE.

3.
Rev Sci Instrum ; 95(9)2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39269240

ABSTRACT

A multi-energy soft x-ray diagnostic is planned to operate in the small aspect ratio tokamak (SMART), consisting of five cameras: one for core measurements, two for edge, and two for divertors. Each camera is equipped with four absolute extreme ultra-violet diodes, with three of them filtered by Ti and Al foils for C and O line emissions, respectively, and Be foils for temperature measurements. In addition, two spectrometers will be installed with a vertical line of sight for impurity control. This study introduces a synthetic model designed to characterize radiated power and soft x-ray emissions. The developed code extracts the radiated power and Zeff values by leveraging distributions of electron density, temperatures, and impurity concentrations. The investigation is centered on the predicted scenarios of SMART's first phase of operation (Ip = 100 kA; Bt = 0.1 T), employing a double-null configuration with positive and negative triangularity. The anticipated impurities encompass C (1%) and Fe (0.01%) from the vessel, as well as O and N (0.1%) from air and water. For simplicity, the distribution is assumed to be homogeneous within the plasma, considering different mixtures with Zeff values ranging between 1 and 2. Finally, the model estimates signal strength for the diagnostic design, proving its feasibility.

4.
Rev Sci Instrum ; 95(9)2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39345168

ABSTRACT

X-ray sources for a range of wavelengths are being considered for in situ calibration of X-ray Imaging Crystal Spectrometers (XICSs) and for monitoring line shifts due to changes in the crystal temperature, which can vary during experimental operation over a day [A. Ince-Cushman et al., Rev. Sci. Instrum. 79, 10E302 (2008), L. Delgado-Aparicio et al., Plasma Phys. Control. Fusion 55, 125011 (2013)]. Such crystal temperature dependent shifts, if not accounted for, could be erroneously interpreted as Doppler shifts leading to errors in plasma flow-velocity measurements. The x-ray sources encompass characteristic x-ray lines falling within the wavelength range of 0.9-4.0 Å, relevant for the XICSs on present and future fusion devices. Several technological challenges associated with the development of x-ray sources for in situ calibration are identified and are being addressed in the design of multiple x-ray tubes, which will be installed inside the spectrometer housing of the XICS for the JT-60SA tokamak. These x-ray sources will be especially useful for in situ calibration between plasma discharges. In this paper, laboratory experiments are described that were conducted with a Cu x-ray source, a heated quartz (102) crystal, and a pixelated Pilatus detector to measure the temperature dependent shifts of the Cu Kα1 and Kα2 lines at 1.5405 and 1.5443 Å, respectively, and to evaluate the 2d-lattice constant for the Bragg reflecting crystal planes as a function of temperature, which, in the case of in situ wavelength calibration, would have to be used for numerical analysis of the x-ray spectra from the plasma.

5.
Rev Sci Instrum ; 95(8)2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39105597

ABSTRACT

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe44+, Xe47+, and Xe51+, based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

6.
Rev Sci Instrum ; 95(9)2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39315908

ABSTRACT

Inertial Confinement Fusion and Magnetic Confinement Fusion (ICF and MCF) follow different paths toward goals that are largely common. In this paper, the claim is made that progress can be accelerated by learning from each other across the two fields. Examples of successful cross-community knowledge transfer are presented that highlight the gains from working together, specifically in the areas of high-resolution x-ray imaging spectroscopy and neutron spectrometry. Opportunities for near- and mid-term collaboration are identified, including in chemical vapor deposition diamond detector technology, using gamma rays to monitor fusion gain, handling neutron-induced backgrounds, developing radiation hard technology, and collecting fundamental supporting data needed for diagnostic analysis. Fusion research is rapidly moving into the igniting and burning regimes, posing new opportunities and challenges for ICF and MCF diagnostics. This includes new physics to probe, such as alpha heating; increasingly harsher environmental conditions; and (in the slightly longer term) the need for new plant monitoring diagnostics. Substantial overlap is expected in all of these emerging areas, where joint development across the two subfields as well as between public and private researchers can be expected to speed up advancement for all.

7.
Phys Rev Lett ; 110(6): 065006, 2013 Feb 08.
Article in English | MEDLINE | ID: mdl-23432265

ABSTRACT

New observations of the formation and dynamics of long-lived impurity-induced helical "snake" modes in tokamak plasmas have recently been carried out on Alcator C-Mod. The snakes form as an asymmetry in the impurity ion density that undergoes a seamless transition from a small helically displaced density to a large crescent-shaped helical structure inside q<1, with a regularly sawtoothing core. The observations show that the conditions for the formation and persistence of a snake cannot be explained by plasma pressure alone. Instead, many features arise naturally from nonlinear interactions in a 3D MHD model that separately evolves the plasma density and temperature.

8.
Phys Rev Lett ; 111(12): 125003, 2013 Sep 20.
Article in English | MEDLINE | ID: mdl-24093268

ABSTRACT

Application of lower hybrid (LH) current drive in tokamak plasmas can induce both co- and countercurrent directed changes in toroidal rotation, depending on the core q profile. For discharges with q(0) <1, rotation increments in the countercurrent direction are observed. If the LH-driven current is sufficient to suppress sawteeth and increase q(0) above unity, the core toroidal rotation change is in the cocurrent direction. This change in sign of the rotation increment is consistent with a change in sign of the residual stress (the divergence of which constitutes an intrinsic torque that drives the flow) through its dependence on magnetic shear.

9.
Phys Rev Lett ; 108(16): 165004, 2012 Apr 20.
Article in English | MEDLINE | ID: mdl-22680727

ABSTRACT

The onset criterion for radiation driven islands [P. H. Rebut and M. Hugon, Plasma Physics and Controlled Nuclear Fusion Research 1984: Proc. 10th Int. Conf. London, 1984, (IAEA, Vienna, 1985), Vol. 2] in combination with a simple cylindrical model of tokamak current channel behavior is consistent with the empirical scaling of the tokamak density limit [M. Greenwald, Nucl. Fusion 28, 2199 (1988)]. Many other unexplained phenomena at the density limit are consistent with this novel physics mechanism.

10.
Rev Sci Instrum ; 93(10): 103508, 2022 Oct 01.
Article in English | MEDLINE | ID: mdl-36319367

ABSTRACT

WEST (tungsten environment in steady-state tokamak) is starting operation for the first time with a water-cooled full tungsten divertor, enabling long pulse operation. Heating is provided by radiofrequency systems, including lower hybrid current drive (LHCD). In this context, a compact multi-energy hard x-ray camera has been installed for energy and space-resolved measurements of the electron temperature, the fast electron tail density produced by LHCD and runaway electrons, and the beam-target emission of tungsten at the target due to fast electron losses interacting with the divertor plates. The diagnostic is a pinhole camera based on a 2D pixel array detector (Pilatus 3 CdTe CMOS Hybrid-Pixel detector produced by DECTRIS). The novelty of this diagnostic technique is the detector's capability of adjusting the threshold energy at pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space and energy-resolved x-ray measurements. This contribution details two important steps in the preparation of the diagnostic operation. First, the in-vessel spatial calibration that was carried out with a radioactive source. Second, the synthetic diagnostic is obtained by the suite of codes ALOHA/C3PO/LUKE/R5-X2, which simulates LH wave propagation and absorption, as well as the fast electron bremsstrahlung production.

11.
Rev Sci Instrum ; 92(5): 053549, 2021 May 01.
Article in English | MEDLINE | ID: mdl-34243280

ABSTRACT

A novel compact multi-energy soft x-ray (ME-SXR) diagnostic based on the PILATUS3 100K x-ray detector has been developed in collaboration between the Princeton Plasma Physics Laboratory and the University of Wisconsin-Madison and tested on the Madison Symmetric Torus (MST) reversed-field pinch. This solid-state photon-counting detector consists of a two-dimensional array of ∼100 000 pixels for which the lower photon absorption cutoff energy can be independently set, allowing it to be configured for a unique combination of simultaneous spatial, spectral, and temporal resolution of ∼1 cm, 100 eV, and 500 Hz, respectively. The diagnostic is highly versatile and can be readily adapted to diverse plasma operating conditions and scientific needs without any required downtime. New results from improved-confinement and quasi-single helicity plasmas in the MST demonstrate how the detector can be applied to study multiple aspects of the evolution of magnetically confined fusion-grade plasmas. These include observing the evolution of thermal emissivity, characterizing the energy of mid-Z excitation lines, extracting the Te profile, and observing the evolution of non-thermal populations. A technique for integrating the ME-SXR diagnostic into an integrated data analysis framework based on Bayesian inference is also presented. This allows ME-SXR measurements to be combined with data for complementary diagnostics in order to simultaneously infer Te and nZ from all available information.

12.
Rev Sci Instrum ; 92(2): 023105, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33648134

ABSTRACT

A multi-energy hard x-ray pin-hole camera based on the PILATUS3 X 100K-M CdTe detector has been developed at the Princeton Plasma Physics Laboratory for installation on the Tungsten Environment in Steady State Tokamak. This camera will be employed to study thermal plasma features such as electron temperature as well as non-thermal effects such as fast electron tails produced by a lower hybrid radiofrequency current drive and the birth of runaway electrons. The innovative aspect of the system lies in the possibility of setting the threshold energy independently for each of the ∼100k pixels of the detector. This feature allows for the measurement of the x-ray emission in multiple energy ranges with adequate space and time resolution (∼1 cm, 2 ms) and coarse energy resolution. In this work, the energy dependence of each pixel was calibrated within the range 15 keV-100 keV using a tungsten x-ray tube and emission from a variety of fluorescence targets (from yttrium to uranium). The data corresponding to pairs of Kα emission lines are fit to the characteristic responsivity ("S-curve"), which describes the detector sensitivity across the 64 possible energy threshold values for each pixel; this novel capability is explored by fine-tuning the voltage of a six-bit digital-analog converter after the charge-sensitive amplifier for each of the ∼100k pixels. This work presents the results of the calibration including a statistical analysis. It was found that the achievable energy resolution is mainly limited by the width of the S-curve to 3 keV-10 keV for threshold energies up to 50 keV, and to ≥20 keV for energies above 60 keV.

13.
Rev Sci Instrum ; 92(4): 043509, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-34243460

ABSTRACT

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (∼1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6-30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ∼100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., Te, nZ, and ΔZeff). The energy dependence of each pixel is calibrated here over the range 3-22 keV. The detector is exposed to a variety of monochromatic sources-fluorescence emission from metallic targets-and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve ("S-curve") that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3-6 keV), medium (4.5-13.5 keV), and high (5.4-21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

14.
Rev Sci Instrum ; 92(7): 073502, 2021 Jul 01.
Article in English | MEDLINE | ID: mdl-34340413

ABSTRACT

A multi-energy soft x-ray pinhole camera has been designed, built, and deployed at the Madison Symmetric Torus to aid the study of particle and thermal transport, as well as MHD stability physics. This novel imaging diagnostic technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. The detector of choice is a PILATUS3 100 K with a 450 µm thick silicon sensor and nearly 100 000 pixels sensitive to photon energies between 1.6 and 30 keV. An ensemble of cubic spline smoothing functions has been applied to the line-integrated data for each time-frame and energy-range, obtaining a reduced standard-deviation when compared to that dominated by photon-noise. The multi-energy local emissivity profiles are obtained from a 1D matrix-based Abel-inversion procedure. Central values of Te can be obtained by modeling the slope of the continuum radiation from ratios of the inverted radial emissivity profiles over multiple energy ranges with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. In tokamak plasmas, a novel application has recently been tested for early detection, 1D imaging, and study of the birth, exponential growth, and saturation of runaway electrons at energies comparable to 100 × Te,0; thus, early results are also presented.

15.
Rev Sci Instrum ; 89(10): 10G120, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399783

ABSTRACT

A new tool has been developed to calculate the spectral, spatial, and temporal responses of multi-energy soft x-ray (ME-SXR) pinhole cameras for arbitrary plasma densities (n e,D), temperature (T e), and impurity densities (n Z). ME-SXR imaging provides a unique opportunity for obtaining important plasma properties (e.g., T e, n Z, and Z eff) by measuring both continuum and line emission in multiple energy ranges. This technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently. Simulations assuming a tangential geometry and DIII-D-like plasmas (e.g., n e,0 ≈ 8 × 1019 m-3 and T e,0 ≈ 2.8 keV) for various impurity (e.g., C, O, Ar, Ni, and Mo) density profiles have been performed. The computed brightnesses range from few 102 counts pixel-1 ms-1 depending on the cut-off energy thresholds, while the maximum allowable count rate is 104 counts pixel-1 ms-1. The typical spatial resolution in the mid-plane is ≈0.5 cm with a photon-energy resolution of 500 eV at a 500 Hz frame rate.

16.
Rev Sci Instrum ; 89(10): 10G119, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399863

ABSTRACT

A multi-energy soft x-ray pin-hole camera based on the PILATUS3 100 K x-ray detector has recently been installed on the Madison Symmetric Torus. This photon-counting detector consists of a two-dimensional array of ∼100 000 pixels for which the photon lower-threshold cutoff energy E c can be independently set for each pixel. This capability allows the measurement of plasma x-ray emissivity in multiple energy ranges with a unique combination of spatial and spectral resolution and the inference of a variety of important plasma properties (e.g., T e, n Z, Z eff). The energy dependence of each pixel is calibrated for the 1.6-6 keV range by scanning individual trimbit settings, while the detector is exposed to fluorescence emission from Ag, In, Mo, Ti, V, and Zr targets. The resulting data for each line are then fit to a characteristic "S-curve" which determines the mapping between the 64 possible trimbit settings for each pixel. The statistical variation of this calibration from pixel-to-pixel was explored, and it was found that the discreteness of trimbit settings results in an effective threshold resolution of ΔE < 100 eV. A separate calibration was performed for the 4-14 keV range, with a resolution of ΔE < 200 eV.

17.
Rev Sci Instrum ; 89(10): 10F107, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399931

ABSTRACT

An in situ wavelength calibration system for the X-ray Imaging Crystal Spectrometer (XICS) on W7-X has been developed to provide routine calibration between plasma shots. XICS is able to determine plasma flow profiles by measuring the Doppler shift of x-ray line emission from highly charged impurity species. A novel design is described that uses an x-ray tube with a cadmium anode placed in front of the diffracting spherically bent crystal. This arrangement provides calibration lines over the full detector extent for both the Ar16+ and Ar17+/Fe24+ spectrometer channels. This calibration system can provide a relative wavelength accuracy of 3 × 10-7 Å across the full spatial extent of the detector, which corresponds to 50 m/s in the W7-X system. An absolute wavelength calibration of 1 × 10-5 Å is expected, corresponding to 1 km/s, based on the current known accuracy of the calibration wavelength and the achievable measurement of the absolute positioning of the hardware. This calibration system can be used to independently calibrate XICS systems on both stellarators and tokamaks, without the need for special plasma conditions often used for calibration, such as locked modes on tokamaks. Experimental and simulated results are shown along with expected results, and the complete design of the calibration hardware that is to be installed in the W7-X XICS system.

18.
Rev Sci Instrum ; 89(10): 10F112, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399885

ABSTRACT

Newly developed large-area pixelated two-dimensional detector and two-crystal assemblies were deployed for the first time on tokamaks to enable time-resolved Bragg-diffracted x-ray imaging with good framing rate and water-cooling capabilities for in-vacuum long-pulse operations. High-quality helium-like (He-like) and hydrogen-like (H-like) argon spectra have been observed simultaneously for the first time on a single detector for a wide range of plasma parameters to infer both ion temperature and rotation profiles and support studies on spontaneous rotation, impurity transport, and RF physics. Since tokamak plasmas rotate in both the poloidal (θ) and toroidal (ϕ) directions, a reliable wavelength calibration is needed to account for the correct Doppler shift as well as to compute the spectrometer's instrumental function. Lyα lines emitted from Cd x-ray tubes are proposed to be used as "markers" to provide an in situ calibration of the EAST's X-ray imaging crystal spectrometer systems measuring He- and H-like argon spectra. The first lab test indicated that the X-ray tube can excite strong Lyα lines at 15 kV voltage and 1 mA current when the crystal is shined for 10 min. Other indirect calibration methods using locked-mode discharge scenarios were also studied as complementary methods.

19.
Rev Sci Instrum ; 89(10): 10F118, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399766

ABSTRACT

The here-described spectrometer was developed for the extended x-ray absorption fine structure spectroscopy of high-density plasmas at the National Ignition Facility. It employs as the Bragg reflecting element a new type of toroidally bent crystal with a constant and very large major radius R and a much smaller, locally varying, minor radius r. The focusing properties of this crystal and the experimental arrangement of the source and detector make it possible to (a) fulfill the conditions for a perfect imaging of an ideal point source for each wavelength, (b) obtain a high photon throughput, (c) obtain a high spectral resolution by eliminating the effects of source-size broadening, and (d) obtain a one-dimensional spatial resolution with a high magnification perpendicular to the main dispersion plane.

20.
Rev Sci Instrum ; 89(10): 10G116, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399822

ABSTRACT

A multi-energy soft x-ray pinhole camera has been designed and built for the Madison Symmetric Torus reversed field pinch to aid the study of particle and thermal-transport, as well as MHD stability physics. This novel imaging diagnostic technique combines the best features from both pulse-height-analysis and multi-foil methods employing a PILATUS3 x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. Further improvements implemented on the new cooled systems allow a maximum count rate of 10 MHz per pixel and sensitivity to the strong Al and Ar emission between 1.5 and 4 keV. The local x-ray emissivity will be measured in multiple energy ranges simultaneously, from which it is possible to infer 1D and 2D simultaneous profile measurements of core electron temperature and impurity density profiles with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. The expected time and space resolutions will be 2 ms and <1 cm, respectively.

SELECTION OF CITATIONS
SEARCH DETAIL