Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
J Infect Dis ; 215(6): 975-983, 2017 03 15.
Article in English | MEDLINE | ID: mdl-28453851

ABSTRACT

Here, we demonstrate that antimicrobial peptides (AMPs) are an effective antibiofilm treatment when applied as catheter lock solutions (CLSs) against S. aureus biofilm infections. The activity of synthetic AMPs (Bac8c, HB43, P18, Omiganan, WMR, Ranalexin, and Polyphemusin) was measured against early and mature biofilms produced by methicillin-resistant S. aureus and methicillin-susceptible S. aureus isolates from patients with device-related infections grown under in vivo-relevant biofilm conditions. The cytotoxic and hemolytic activities of the AMPs against human cells and their immunomodulatory potential in human blood were also characterized. The D-Bac8c2,5Leu variant emerged as the most effective AMP during in vitro studies and was also highly effective in eradicating S. aureus biofilm infection when used in a CLS rat central venous catheter infection model. These data support the potential use of D-Bac8c2,5Leu, alone or in combination with other AMPs, in the treatment of S. aureus intravenous catheter infections.


Subject(s)
Anti-Bacterial Agents/pharmacology , Biofilms/drug effects , Catheter-Related Infections/drug therapy , Methicillin-Resistant Staphylococcus aureus/drug effects , Peptides/pharmacology , Staphylococcal Infections/drug therapy , Animals , Cytokines/blood , Disease Models, Animal , Humans , Microbial Sensitivity Tests , Peptides, Cyclic/pharmacology , Rats , Rats, Sprague-Dawley , Vancomycin/administration & dosage
2.
J Antimicrob Chemother ; 72(3): 744-753, 2017 03 01.
Article in English | MEDLINE | ID: mdl-27999062

ABSTRACT

Objectives: Biofilm infections of intravascular catheters caused by Staphylococcus aureus may be treated with catheter lock solutions (CLSs). Here we investigated the antibacterial activity, cytotoxicity and CLS potential of 5-hydroxyethyl-3-tetradecanoyltetramic acid (5HE-C14-TMA) compared with the related compounds 3-tetradecanoyltetronic (C14-TOA) and 3-tetradecanoylthiotetronic (C14-TTA), which are variants of quorum sensing signalling molecules produced by Pseudomonas aeruginosa . Methods: Antibacterial activity and mechanism of action of 5HE-C14-TMA, C14-TOA and C14-TTA were determined via MIC, bacterial killing, membrane potential and permeability assays. Susceptibility of S. aureus biofilms formed in the presence of plasma in vitro was investigated, MTT cytotoxicity testing was undertaken and cytokine release in human blood upon exposure to 5HE-C14-TMA and/or S. aureus biofilms was quantified. The effectiveness of 5HE-C14-TMA as CLS therapy in vivo was assessed using a rat intravascular catheter biofilm infection model. Results: MICs of 5HE-C14-TMA, C14-TOA and C14-TTA ranged from 2 to 4 mg/L. 5HE-C14-TMA and C14-TTA were bactericidal; all three compounds perturbed the staphylococcal membrane by increasing membrane permeability, depolarized the transmembrane potential and caused ATP leakage. Cytotoxicity and haemolytic activity were compound and target cell type-dependent. 5HE-C14-TMA reduced S. aureus biofilm viability in a dose-dependent manner in vitro and in vivo and did not trigger release of cytokines in human blood, but inhibited the high levels of IL-8 and TNF-α induced by S. aureus biofilms. Conclusions: 5HE-C14-TMA, C14-TOA and C14-TTA are membrane-active agents. 5HE-C14-TMA was the most potent, eradicating S. aureus biofilms at 512-1024 mg/L both in vitro and in vivo as a CLS.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Catheter-Related Infections/drug therapy , Pyrrolidinones/therapeutic use , Staphylococcal Infections/drug therapy , Staphylococcus aureus/drug effects , Vascular Access Devices/microbiology , Animals , Anti-Bacterial Agents/chemistry , Anti-Bacterial Agents/isolation & purification , Anti-Bacterial Agents/pharmacology , Biofilms/drug effects , Catheter-Related Infections/microbiology , Drug Discovery , Humans , Microbial Sensitivity Tests , Microbial Viability , Pseudomonas aeruginosa/metabolism , Pyrrolidinones/pharmacology , Quorum Sensing , Rats , Staphylococcal Infections/microbiology , Staphylococcus aureus/physiology , Vancomycin/pharmacology
3.
FEMS Microbiol Lett ; 366(9)2019 05 01.
Article in English | MEDLINE | ID: mdl-31095299

ABSTRACT

Prevention of device related infections due to Staphylococcus aureus biofilms on devices represents a significant challenge. Such infections have recently been shown to be dependent on the coagulation pathway via activation of pro-thrombin and fibrin production. Three direct-thrombin inhibitors, argatroban, hirudin and dabigatran, were examined to determine their effect on preventing S. aureus biofilm on plastic biochip surfaces under shear stress using an in vivo relevant model of infection. Surface functionalization of polyurethane discs via dityrosine covalent crosslinking with hirudin was performed and changes in bacterial density and microscopic appearances determined. The three direct-thrombin inhibitors prevented S. aureus biofilm formation on plasma-coated surfaces treated with these agents. Coating of polyurethane with one of these agents, hirudin, significantly inhibited biofilm formation on the modified surface. These findings reveal the exciting potential for coating biomaterial surfaces with direct thrombin inhibitors to prevent staphylococcal binding and subsequent device-related infections.


Subject(s)
Anti-Bacterial Agents/pharmacology , Antithrombins/pharmacology , Bacterial Adhesion/drug effects , Biofilms/drug effects , Coated Materials, Biocompatible , Equipment and Supplies/microbiology , Staphylococcus aureus/drug effects , Biofilms/growth & development , Humans , Microscopy, Electron, Scanning , Polyurethanes/chemistry , Polyurethanes/pharmacology , Staphylococcal Infections/microbiology , Staphylococcal Infections/prevention & control , Staphylococcus aureus/ultrastructure , Surface Properties , Thrombin/metabolism
4.
Methods Mol Biol ; 1106: 157-66, 2014.
Article in English | MEDLINE | ID: mdl-24222464

ABSTRACT

Rapid screening of biofilm forming capacity by Staphylococcus epidermidis is possible using in vitro assays with 96-well plates. This method first developed by Christensen et al. in 1985 is fast and does not require specialized instruments. Thus, laboratories with standard microbiology infrastructure and a 96-well plate reader can easily use this technique to generate data on the biofilm phenotypes of multiple S. epidermidis strains and clinical isolates. Furthermore, this method can be adapted to gain insights into biofilm regulation and the characteristics of biofilms produced by different S. epidermidis isolates. Although this assay is extremely useful for showing whether individual strains are biofilm-positive or biofilm-negative and distinguishing between form weak, moderate or strong biofilm, it is important to acknowledge that the absolute levels of biofilm produced by an individual strain can vary significantly between experiments meaning that strict adherence to the protocol used is of paramount importance. Furthermore, measuring biofilm under static conditions does not generally reflect in vivo conditions in which bacteria are often subjected to shear stresses under flow conditions. Hence, the biofilm characteristics of some strains are dramatically different under flow and static conditions. Nevertheless, rapid measurement of biofilm production under static conditions is a useful tool in the analysis of the S. epidermidis biofilm phenotype.


Subject(s)
Biofilms/growth & development , Staphylococcus epidermidis/growth & development , Bacterial Adhesion , Bacterial Proteins/metabolism , Culture Media , Culture Techniques , Extracellular Matrix/metabolism , Polystyrenes/chemistry , Staphylococcus epidermidis/metabolism , Staphylococcus epidermidis/physiology
SELECTION OF CITATIONS
SEARCH DETAIL