Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
RSC Adv ; 10(45): 27042-27049, 2020 Jul 15.
Article in English | MEDLINE | ID: mdl-35515798

ABSTRACT

The commercially-available colorimetric urine dipstic for the early detection of urinary tract infection (UTI) has several limitations. The quantitative determination of urinary leukocyte esterase (LE) for predicting UTI remains uncertain. This study presents a paper-based analytical device to detect LE (LE-PAD) as a point-of-care quantitative test for UTI. The LE-PAD is composed of a coating of mixed 3-(N-tosyl-L-alaninyloxy)-5-phenylpyrrole (PE) and 1-diazo-2-naphthol-4-sulfonic acid (DAS) deposited onto a silver conducting film (Ag film). The LE/urine reacts with the PE and DAS, and the resulting products in turn react with the silver coating, causing a change in resistivity. The quantitative calibration curve was established in this study and has been used to analyse urine samples from inpatients with urinary catheters (n = 21). The results revealed that the level of LE determined by LE-PADs was predictive of UTI diagnosis with an area under the receiver operating characteristic curve of 0.875 (95% confidence interval, 0.704-1.000). Using an appropriate cut-off value, the sensitivity and specificity of UTI diagnosis by LE-PAD were 87.5% and 92.3%, while the LE-positivities of urine dipstics were 62.5% and 76.9%, respectively. For UTI diagnosis, the LE-PAD demonstrated positive and negative likelihood ratios of 11.38 and 0.14, suggesting that the novel LE-PAD is a reliable test.

2.
Polymers (Basel) ; 10(9)2018 Sep 07.
Article in English | MEDLINE | ID: mdl-30960926

ABSTRACT

We report on a selective paper-based method and a microfluidic paper-based analytical device (µPAD) for the detection of human plasma glucose and tear glucose using carbopol polymer-encapsulated Au(I) complex (AuC2C6H4OMe)2(Ph2P(C6H4)3PPh2), (B5). To the best of our knowledge, this demonstrates for the first time the glucose sensing based on dual emission, i.e., fluorescence and phosphorescence, of a single type molecule on the carbopol polymer. Upon addition of human blood treated with anticoagulants to µPADs, plasma is separated from the blood and flows into the response region of the µPADs to react with carbopol polymer-encapsulated B5, in which the ratiometric luminescence is analyzed. The plasma glucose concentration can be quantitively detected at 1.0⁻50.0 mM on paper, and tear glucose can be detected at 0.1⁻4.0 mM on µPADs. Owing to the structural design, this device has superior ratiometric changes of dual emission over other Au(I) complexes for signal transduction. The encapsulation of carbopol polymer also offers long-term storage stability. In tear measurement, carbopol polymer is not only used to encapsulate enzyme to remain the enzyme's activity, but also played as a glue (or media) to connect microfluidic channel and response region. This further improves the sensitivity and limit of detection for glucose. Moreover, this sensor provides a faster response time, a wider range for glucose sensing than reported previously, and no statistical difference of the data from a commercial glucometer, allowing for practical diagnosis of diabetes and healthy individuals.

SELECTION OF CITATIONS
SEARCH DETAIL