Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Nanotechnology ; 31(20): 204002, 2020 May 15.
Article in English | MEDLINE | ID: mdl-32106108

ABSTRACT

We report on the use of a sacrificial AlAs segment to enable substrate reuse for nanowire synthesis. A silicon nitride template was deposited on a p-type GaAs substrate. Then a pattern was transferred to the substrate by nanoimprint lithography and reactive ion etching. Thermal evaporation was used to define Au seed particles. Metalorganic vapour phase epitaxy was used to grow AlAs-GaAs NWs in the vapour-liquid-solid growth mode. The yield of synthesised nanowires, compared to the number expected from the patterned template, was more than 80%. After growth, the nanowires were embedded in a polymer and mechanically removed from the parent substrate. The parent substrate was then immersed in an HCl:H2O (1:1) mixture to dissolve the remaining stub of the sacrificial AlAs segment. The pattern fidelity was preserved after peeling off the nanowires and cleaning, and the semiconductor surface was flat and ready for reuse. Au seed particles were then deposited on the substrate by use of pulse electrodeposition, which was selective to the openings in the growth template, and then nanowires were regrown. The yield of regrowth was less optimal compared to the first growth but the pattern was preserved. Our results show a promising approach to reduce the final cost of III-V nanowire based solar cells.

2.
Enferm Intensiva ; 28(4): 178-186, 2017.
Article in English, Spanish | MEDLINE | ID: mdl-28890209

ABSTRACT

OBJECTIVE: To analyse whether adherence to non-pharmacological measures in the prevention of ventilator-associated pneumonia (VAP) is associated with nursing workload. METHODS: A prospective observational study performed in a single medical-surgical ICU. Nurses in charge of patients under ventilator support were assessed. VARIABLES: knowledge questionnaire, application of non-pharmacological VAP prevention measures, and workload (Nine Equivalents of Nursing Manpower Use Score). Phases: 1) the nurses carried out a educational programme, consisting of 60-minute lectures on non-pharmacological measures for VAP prevention, and at the end completed a questionnaire knowledge; 2) observation period; 3) knowledge questionnaire. RESULTS: Among 67 ICU-staff nurses, 54 completed the educational programme and were observed. A total of 160 observations of 49 nurses were made. Adequate knowledge was confirmed in both the initial and final questionnaires. Application of preventive measures ranged from 11% for hand washing pre-aspiration to 97% for the use of a sterile aspiration probe. The Nine Equivalents of Nursing Manpower Use Score was 50±13. No significant differences were observed between the association of the nurses' knowledge and the application of preventive measures or between workload and the application of preventive measures. CONCLUSIONS: Nurses' knowledge of VAP prevention measures is not necessarily applied in daily practice. Failure to follow these measures is not subject to lack of knowledge or to increased workload, but presumably to contextual factors.


Subject(s)
Critical Care Nursing , Guideline Adherence/statistics & numerical data , Pneumonia, Ventilator-Associated/prevention & control , Workload , Adult , Female , Humans , Male , Middle Aged , Pilot Projects , Prospective Studies
3.
Med Intensiva ; 38(4): 226-36, 2014 May.
Article in English, Spanish | MEDLINE | ID: mdl-24594437

ABSTRACT

BACKGROUND: "Zero-VAP" is a proposal for the implementation of a simultaneous multimodal intervention in Spanish intensive care units (ICU) consisting of a bundle of ventilator-associated pneumonia (VAP) prevention measures. METHODS/DESIGN: An initiative of the Spanish Societies of Intensive Care Medicine and of Intensive Care Nurses, the project is supported by the Spanish Ministry of Health, and participation is voluntary. In addition to guidelines for VAP prevention, the "Zero-VAP" Project incorporates an integral patient safety program and continuous online validation of the application of the bundle. For the latter, VAP episodes and participation indices are entered into the web-based Spanish ICU Infection Surveillance Program "ENVIN-HELICS" database, which provides continuous information about local, regional and national VAP incidence rates. Implementation of the guidelines aims at the reduction of VAP to less than 9 episodes per 1000 days of mechanical ventilation. A total of 35 preventive measures were initially selected. A task force of experts used the Grading of Recommendations, Assessment, Development and Evaluation Working Group methodology to generate a list of 7 basic "mandatory" recommendations (education and training in airway management, strict hand hygiene for airway management, cuff pressure control, oral hygiene with chlorhexidine, semi-recumbent positioning, promoting measures that safely avoid or reduce time on ventilator, and discouraging scheduled changes of ventilator circuits, humidifiers and endotracheal tubes) and 3 additional "highly recommended" measures (selective decontamination of the digestive tract, aspiration of subglottic secretions, and a short course of iv antibiotic). DISCUSSION: We present the Spanish VAP prevention guidelines and describe the methodology used for the selection and implementation of the recommendations and the organizational structure of the project. Compared to conventional guideline documents, the associated safety assurance program, the online data recording and compliance control systems, as well as the existence of a pre-defined objective are the distinct features of "Zero VAP".


Subject(s)
Intensive Care Units , Pneumonia, Ventilator-Associated/prevention & control , Humans , Spain
4.
Med. intensiva ; 38(4): 226-236, may 2014.
Article in English | LILACS, BIGG | ID: biblio-965327

ABSTRACT

"BACKGROUND: ""Zero-VAP"" is a proposal for the implementation of a simultaneous multimodal intervention in Spanish intensive care units (ICU) consisting of a bundle of ventilator-associated pneumonia (VAP) prevention measures. METHODS/DESIGN: An initiative of the Spanish Societies of Intensive Care Medicine and of Intensive Care Nurses, the project is supported by the Spanish Ministry of Health, and participation is voluntary. In addition to guidelines for VAP prevention, the ""Zero-VAP"" Project incorporates an integral patient safety program and continuous online validation of the application of the bundle. For the latter, VAP episodes and participation indices are entered into the web-based Spanish ICU Infection Surveillance Program ""ENVIN-HELICS"" database, which provides continuous information about local, regional and national VAP incidence rates. Implementation of the guidelines aims at the reduction of VAP to less than 9 episodes per 1000 days of mechanical ventilation. A total of 35 preventive measures were initially selected. A task force of experts used the Grading of Recommendations, Assessment, Development and Evaluation Working Group methodology to generate a list of 7 basic ""mandatory"" recommendations (education and training in airway management, strict hand hygiene for airway management, cuff pressure control, oral hygiene with chlorhexidine, semi-recumbent positioning, promoting measures that safely avoid or reduce time on ventilator, and discouraging scheduled changes of ventilator circuits, humidifiers and endotracheal tubes) and 3 additional ""highly recommended"" measures (selective decontamination of the digestive tract, aspiration of subglottic secretions, and a short course of iv antibiotic). DISCUSSION: We present the Spanish VAP prevention guidelines and describe the methodology used for the selection and implementation of the recommendations and the organizational structure of the project. Compared to conventional guideline documents, the associated safety assurance program, the online data recording and compliance control systems, as well as the existence of a pre-defined objective are the distinct features of ""Zero VAP"""


Subject(s)
Humans , Pneumonia, Ventilator-Associated , Pneumonia, Ventilator-Associated/prevention & control , Intensive Care Units
SELECTION OF CITATIONS
SEARCH DETAIL