1.
Eur Heart J ; 45(14): 1241-1251, 2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38426911

ABSTRACT

BACKGROUND AND AIMS: Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. METHODS: All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine-Gray competing risk models. RESULTS: 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6-64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%-5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36-.61; P < .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%-6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P < .001). CONCLUSIONS: Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.


Subject(s)
Arrhythmias, Cardiac , Pacemaker, Artificial , Humans , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/etiology , Treatment Outcome , Equipment Design , Pacemaker, Artificial/adverse effects , Registries , Cardiac Pacing, Artificial/adverse effects
2.
Europace ; 26(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38449430

ABSTRACT

The second generation of transcatheter pacing systems, called Micra AV, can provide atrioventricular (AV) synchronous pacing via a new pacing algorithm relying on sensing mechanical atrial contraction. Several novel programming parameters were introduced to enable AV synchronous pacing, including an A3 window and A4 window as well as a conduction mode switch and an activity mode switch. In addition to several automated features, manual programming optimization of some of the novel parameters is key to improving AV synchrony. A solid knowledge of the features and their programming is essential for electrophysiologists implanting or following patients with Micra AV devices. Differences in programming optimization might partially explain the high variability of AV synchrony published in real-world data reports. This article reviews the key programming parameters of Micra AV. Subsequently, optimal programming recommendations for defined patient profiles are presented. Those were established by consensus within an expert panel comprised of 11 European electrophysiologists from high-volume Micra AV centres. The patient profiles were (1) high degree AV block and slow sinus rhythm; (2) high degree AV block and fast sinus rhythm; and (3) intermittent AV block. The panel recommended to evaluate the mechanical atrial activity on transthoracic echocardiography prior to implant. It was also agreed that Auto A3 Threshold and Tracking Check should be turned off in all patients, AV conduction mode switch should be turned off in all patients with high degree AV block, and the lower rate should be programmed to 50 bpm with exceptions based on individual clinical assessment. Future studies will be useful to evaluate the strength of those recommendations to improve the AV synchrony.


Subject(s)
Atrioventricular Block , Pacemaker, Artificial , Humans , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Cardiac Pacing, Artificial/adverse effects , Arrhythmias, Cardiac/therapy , Heart Rate/physiology
3.
Eur Heart J ; 44(40): 4246-4255, 2023 Oct 21.
Article in English | MEDLINE | ID: mdl-37638973

ABSTRACT

BACKGROUND AND AIMS: High percentages of atrial pacing have been associated with an increased risk of atrial fibrillation. This study is aimed at evaluating whether atrial pacing minimization in patients with sinus node dysfunction reduces the incidence of atrial fibrillation. METHODS: In a nationwide, randomized controlled trial, 540 patients with sinus node dysfunction and an indication for first pacemaker implantation were assigned to pacing programmed to a base rate of 60 bpm and rate-adaptive pacing (DDDR-60) or pacing programmed to a base rate of 40 bpm without rate-adaptive pacing (DDD-40). Patients were followed on remote monitoring for 2 years. The primary endpoint was time to first episode of atrial fibrillation longer than 6 min. Secondary endpoints included longer episodes of atrial fibrillation, and the safety endpoint comprised a composite of syncope or presyncope. RESULTS: The median percentage of atrial pacing was 1% in patients assigned to DDD-40 and 49% in patients assigned to DDDR-60. The primary endpoint occurred in 124 patients (46%) in each treatment group (hazard ratio [HR] 0.97, 95% confidence interval [CI] 0.76-1.25, P = .83). There were no between-group differences in atrial fibrillation exceeding 6 or 24 h, persistent atrial fibrillation, or cardioversions for atrial fibrillation. The incidence of syncope or presyncope was higher in patients assigned to DDD-40 (HR 1.71, 95% CI 1.13-2.59, P = .01). CONCLUSIONS: Atrial pacing minimization in patients with sinus node dysfunction does not reduce the incidence of atrial fibrillation. Programming a base rate of 40 bpm without rate-adaptive pacing is associated with an increased risk of syncope or presyncope.

4.
Am Heart J ; 263: 112-122, 2023 09.
Article in English | MEDLINE | ID: mdl-37220821

ABSTRACT

BACKGROUND: Cardiac resynchronization therapy (CRT) improves symptoms, health-related quality of life and long-term survival in patients with systolic heart failure (HF) and shortens QRS duration. However, up to one third of patients attain no measurable clinical benefit from CRT. An important determinant of clinical response is optimal choice in left ventricular (LV) pacing site. Observational data have shown that achieving an LV lead position at a site of late electrical activation is associated with better clinical and echocardiographic outcomes compared to standard placement, but mapping-guided LV lead placement towards the site of latest electrical activation has never been investigated in a randomized controlled trial (RCT). The purpose of this study was to evaluate the effect of targeted positioning of the LV lead towards the latest electrically activated area. We hypothesize that this strategy is superior to standard LV lead placement. METHODS: The DANISH-CRT trial is a national, double-blinded RCT (ClinicalTrials.gov NCT03280862). A total of 1,000 patients referred for a de novo CRT implantation or an upgrade to CRT from right ventricular pacing will be randomized 1:1 to receive conventional LV lead positioning preferably in a nonapical posterolateral branch of the coronary sinus (CS) (control group) or targeted positioning of the LV lead to the CS branch with the latest local electrical LV activation (intervention group). In the intervention group, late activation will be determined using electrical mapping of the CS. The primary endpoint is a composite of death and nonplanned HF hospitalization. Patients are followed for a minimum of 2 years and until 264 primary endpoints occurred. Analyses will be conducted according to the intention-to-treat principle. Enrollment for this trial began in March 2018, and per April 2023, a total of 823 patients have been included. Enrollment is expected to be complete by mid-2024. CONCLUSIONS: The DANISH-CRT trial will clarify whether mapping-guided positioning of the LV lead according to the latest local electrical activation in the CS is beneficial for patients in terms of reducing the composite endpoint of death or nonplanned hospitalization for heart failure. Results from this trial are expected to impact future guidelines on CRT. GOV IDENTIFIER: NCT03280862.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Cardiac Resynchronization Therapy/methods , Cardiac Resynchronization Therapy Devices , Incidence , Treatment Outcome , Heart Ventricles/diagnostic imaging , Hospitalization
5.
Europace ; 25(6)2023 06 02.
Article in English | MEDLINE | ID: mdl-37345858

ABSTRACT

AIMS: Use of an absorbable antibacterial envelope during implantation prevents cardiac implantable electronic device infections in patients with a moderate-to-high infection risk. Previous studies demonstrated that an envelope is cost-effective in high-risk patients within German, Italian, and English healthcare systems, but these analyses were based on limited data and may not be generalizable to other healthcare settings. METHODS AND RESULTS: A previously published decision-tree-based cost-effectiveness model was used to compare the costs per quality-adjusted life year (QALY) associated with adjunctive use of an antibacterial envelope for infection prevention compared to standard-of-care intravenous antibiotics. The model was adapted using data from a Danish observational two-centre cohort study that investigated infection-risk patients undergoing cardiac resynchronization therapy (CRT) reoperations with and without an antibacterial envelope (n = 1943). We assumed a cost-effectiveness threshold of €34 125/QALY gained, based on the upper threshold used by the National Institute for Health and Care Excellence (£30 000). An antibacterial envelope was associated with an incremental cost-effectiveness ratio (ICER) of €12 022 per QALY in patients undergoing CRT reoperations, thus indicating that the envelope is cost-effective when compared with standard of care. A separate analysis stratified by device type showed ICERS of €6227 (CRT defibrillator) and €29 177 (CRT pacemaker) per QALY gained. CONCLUSIONS: Cost-effectiveness ratios were favourable for patients undergoing CRT reoperations in the Danish healthcare system, and thus are in line with previous studies. Results from this study can contribute to making the technology available to Danish patients and align preventive efforts in the pacemaker and ICD area.


Subject(s)
Cardiac Resynchronization Therapy , Humans , Reoperation , Cardiac Resynchronization Therapy/adverse effects , Cost-Benefit Analysis , Cohort Studies , Anti-Bacterial Agents/therapeutic use , Denmark
6.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-37129985

ABSTRACT

AIMS: Reduced psychological health is associated with adverse patient outcomes and higher mortality. We aimed to examine if a Brugada syndrome (BrS) diagnosis and symptomatic disease presentation were associated with an increased risk of new-onset depression or anxiety and all-cause mortality. METHODS AND RESULTS: All Danish patients diagnosed with BrS (2006-2018) with no history of psychiatric disease and available for ≥6 months follow-up were identified using nationwide registries and followed for up to 5 years after diagnosis. The development of clinical depression or anxiety was evaluated using the prescription of medication and diagnosis codes. Factors associated with developing new-onset depression or anxiety were determined using a multivariate Cox proportional hazards regression model. Disease manifestation was categorized as symptomatic (aborted cardiac arrest, ventricular tachycardia, or syncope) or asymptomatic/unspecified at diagnosis. A total of 223 patients with BrS and no history of psychiatric disease were identified (72.6% male, median age at diagnosis 46 years, 45.3% symptomatic). Of these, 15.7% (35/223) developed new-onset depression or anxiety after BrS diagnosis (median follow-up 5.0 years). A greater proportion of symptomatic patients developed new-onset depression or anxiety compared with asymptomatic patients [21/101 (20.8%) and 14/122 (11.5%), respectively, P = 0.08]. Symptomatic disease presentation (HR 3.43, 1.46-8.05) and older age (lower vs. upper tertile: HR 4.41, 1.42-13.63) were significantly associated with new-onset depression or anxiety. All-cause mortality in this group of patients treated according to guidelines was low (n = 4, 1.8%); however, 3/4 developed depression or anxiety before death. CONCLUSION: Approximately, one-sixth of patients with BrS developed new-onset depression or anxiety following a diagnosis of BrS. Symptomatic BrS disease manifestation was significantly associated with new-onset depression or anxiety.


Subject(s)
Brugada Syndrome , Humans , Male , Middle Aged , Female , Brugada Syndrome/diagnosis , Brugada Syndrome/epidemiology , Brugada Syndrome/complications , Depression/diagnosis , Depression/epidemiology , Death, Sudden, Cardiac/etiology , Electrocardiography/methods , Risk Assessment/methods , Anxiety/diagnosis , Anxiety/epidemiology , Denmark/epidemiology
7.
Europace ; 25(6)2023 06 02.
Article in English | MEDLINE | ID: mdl-37335977

ABSTRACT

AIMS: To date, potential differences in outcomes for immigrants and non-immigrants with a cardiac resynchronization therapy (CRT), in a European setting, remain underutilized and unknown. Hence, we examined the efficacy of CRT measured by heart failure (HF)-related hospitalizations and all-cause mortality among immigrants and non-immigrants. METHODS AND RESULTS: All immigrants and non-immigrants who underwent first-time CRT implantation in Denmark (2000-2017) were identified from nationwide registries and followed for up to 5 years. Differences in HF related hospitalizations and all-cause mortality were evaluated by Cox regression analyses. From 2000 to 2017, 369 of 10 741 (3.4%) immigrants compared with 7855 of 223 509 (3.5%) non-immigrants with a HF diagnosis underwent CRT implantation. The origins of the immigrants were Europe (61.2%), Middle East (20.1%), Asia-Pacific (11.9%), Africa (3.5%), and America (3.3%). We found similar high uptake of HF guideline-directed pharmacotherapy before and after CRT and a consistent reduction in HF-related hospitalizations the year before vs. the year after CRT (61% vs. 39% for immigrants and 57% vs. 35% for non-immigrants). No overall difference in 5-year mortality among immigrants and non-immigrants was seen after CRT [24.1% and 25.8%, respectively, P-value = 0.50, hazard ratio (HR) = 1.2, 95% confidence interval (CI): 0.8-1.7]. However, immigrants of Middle Eastern origin had a higher mortality rate (HR = 2.2, 95% CI: 1.2-4.1) compared with non-immigrants. Cardiovascular causes were responsible for the majority of deaths irrespective of immigration status (56.7% and 63.9%, respectively). CONCLUSION: No overall differences in efficacy of CRT in improving outcomes between immigrants and non-immigrants were identified. Although numbers were low, a higher mortality rate among immigrants of Middle Eastern origin was identified compared with non-immigrants.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Humans , Cardiac Resynchronization Therapy/methods , Treatment Outcome , Cardiac Resynchronization Therapy Devices/adverse effects , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/etiology , Proportional Hazards Models , Defibrillators, Implantable/adverse effects
8.
Europace ; 25(12)2023 12 06.
Article in English | MEDLINE | ID: mdl-38055845

ABSTRACT

AIMS: Modern clinical management of patients with an implantable cardioverter defibrillator (ICD) largely consists of remote device monitoring, although a subset is at risk of mental health issues post-implantation. We compared a 12-month web-based intervention consisting of goal setting, monitoring of patients' mental health-with a psychological intervention if needed-psychoeducational support from a nurse, and an online patient forum, with usual care on participants' device acceptance 12 months after implantation. METHODS AND RESULTS: This national, multi-site, two-arm, non-blinded, randomized, controlled, superiority trial enrolled 478 first-time ICD recipients from all 6 implantation centres in Denmark. The primary endpoint was patient device acceptance measured by the Florida Patient Acceptance Survey (FPAS; general score range = 0-100, with higher scores indicating higher device acceptance) 12 months after implantation. Secondary endpoints included symptoms of depression and anxiety. The primary endpoint of device acceptance was not different between groups at 12 months [B = -2.67, 95% confidence interval (CI) (-5.62, 0.29), P = 0.08]. Furthermore, the secondary endpoint analyses showed no significant treatment effect on either depressive [B = -0.49, 95% CI (-1.19; 0.21), P = 0.17] or anxiety symptoms [B = -0.39, 95% CI (-0.96; 0.18), P = 0.18]. CONCLUSION: The web-based intervention as supplement to usual care did not improve patient device acceptance nor symptoms of anxiety and depression compared with usual care. This specific web-based intervention thus cannot be recommended as a standardized intervention in ICD patients.


Subject(s)
Defibrillators, Implantable , Quality of Life , Humans , Anxiety/prevention & control , Anxiety/psychology , Delivery of Health Care , Internet , Quality of Life/psychology , Surveys and Questionnaires
9.
Eur Heart J ; 43(47): 4946-4956, 2022 12 14.
Article in English | MEDLINE | ID: mdl-36263789

ABSTRACT

AIMS: Cardiac implantable electronic device (CIED) infection is a severe complication to modern management of cardiac arrhythmias. The CIED type and the type of surgery are recognized as risk factors for CIED infections, but knowledge of patient-related risk factors is scarce. This study aimed to identify lifelong patient-related risk factors for CIED infections. METHODS AND RESULTS: Consecutive Danish patients undergoing a CIED implantation or reoperation between January 1996 and April 2018 were included. The cohort consisted of 84 429 patients undergoing 108 494 CIED surgeries with a combined follow-up of 458 257 CIED-years. A total of 1556 CIED explantations were classified as either pocket (n = 1022) or systemic CIED infection (n = 534). Data were cross-linked with records from the Danish National Patient Registry and the Danish National Prescription Registry. Using multiple-record and multiple-event per subject proportional hazard analysis, specific patient-related risk factors were identified but with several variations amongst the subtypes of CIED infection. CIED reoperations were associated with the highest risk of pocket CIED infection but also CIED type, young age, and prior valvular surgery [hazard ratio (HR): 1.62, 95% confidence interval (CI): 1.29-2.04]. Severe renal insufficiency/dialysis (HR: 2.40, 95% CI: 1.65-3.49), dermatitis (HR: 2.80, 95% CI: 1.92-4.05), and prior valvular surgery (HR: 2.09, 95% CI: 1.59-2.75) were associated with the highest risk of systemic CIED infections. Congestive heart failure, ischaemic heart disease, malignancy, chronic obstructive pulmonary disease, and temporary pacing were not significant at multivariate analysis. CONCLUSION: Specific comorbidities and surgical procedures were associated with a higher risk of CIED infections but with variations amongst pocket and systemic CIED infection. Pocket CIED infections were associated with CIED reoperations, young age and more complex type of CIED, whereas systemic CIED infections were associated with risk factors predisposing to bacteraemia.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Prosthesis-Related Infections , Humans , Pacemaker, Artificial/adverse effects , Defibrillators, Implantable/adverse effects , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/etiology , Incidence , Risk Factors , Electronics , Denmark/epidemiology , Retrospective Studies
10.
Europace ; 24(3): 421-429, 2022 Mar 02.
Article in English | MEDLINE | ID: mdl-34431989

ABSTRACT

AIMS: Cardiac resynchronization therapy (CRT) reoperations are associated with a particularly high risk of device-related infection (DRI). An antibacterial envelope reduces the occurrence of DRIs in a broad population of moderate-tohigh-risk patients. To investigate the efficacy of an antibacterial envelope in a very high-risk population of patients undergoing CRT reoperation. METHODS AND RESULTS: In this Danish two-centre, observational cohort study, we included consecutive patients who underwent a CRT pacemaker- or defibrillator reoperation procedure between January 2008 and November 2019. We obtained data from the Danish Pacemaker and ICD Register and through systematic medical chart review. Follow-up was restricted to 2 years. A total of 1943 patients were included in the study of which 736 (38%) received an envelope. Envelope patients had more independent risk factors for infection than non-envelope patients. Sixty-seven (3.4%) patients met the primary endpoint of DRI requiring device system extraction; 50 in the non-envelope group and 17 in the envelope group [4.1% vs. 2.3%, adjusted hazard ratio (HR) 0.52, 95% confidence interval (CI) 0.30-0.90; P = 0.021]. This difference persisted in propensity score analysis (HR 0.51, 95% CI 0.29-0.90; P = 0.019). CONCLUSION: Use of an antibacterial envelope was associated with a clinically and statistically significant reduction in DRIs in patients undergoing CRT reoperations. Our results were comparable to those recently reported from a large randomized controlled trial, which is suggestive of a proportional effect of the envelope even in very high-risk patients.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Pacemaker, Artificial , Anti-Bacterial Agents/therapeutic use , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy Devices , Defibrillators, Implantable/adverse effects , Heart Failure/therapy , Humans , Pacemaker, Artificial/adverse effects , Reoperation , Risk Factors , Treatment Outcome
11.
Europace ; 24(1): 165-172, 2022 01 04.
Article in English | MEDLINE | ID: mdl-34455442

ABSTRACT

AIMS: To develop a suite of quality indicators (QIs) for the evaluation of the care and outcomes for adults undergoing cardiac pacing. METHODS AND RESULTS: Under the auspice of the Clinical Practice Guideline Quality Indicator Committee of the European Society of Cardiology (ESC), the Working Group for cardiac pacing QIs was formed. The Group comprised Task Force members of the 2021 ESC Clinical Practice Guidelines on Cardiac Pacing and Cardiac Resynchronization Therapy, members of the European Heart Rhythm Association, international cardiac device experts, and patient representatives. We followed the ESC methodology for QI development, which involved (i) the identification of the key domains of care by constructing a conceptual framework of the management of patients receiving cardiac pacing, (ii) the development of candidate QIs by conducting a systematic review of the literature, (iii) the selection of the final set of QIs using a modified-Delphi method, and (iv) the evaluation of the feasibility of the developed QIs. Four domains of care were identified: (i) structural framework, (ii) patient assessment, (iii) pacing strategy, and (iv) clinical outcomes. In total, seven main and four secondary QIs were selected across these domains and were embedded within the 2021 ESC Guidelines on Cardiac Pacing and Cardiac Resynchronization therapy. CONCLUSION: By way of a standardized process, 11 QIs for cardiac pacing were developed. These indicators may be used to quantify adherence to guideline-recommended clinical practice and have the potential to improve the care and outcomes of patients receiving cardiac pacemakers.


Subject(s)
Cardiac Resynchronization Therapy , Cardiology , Pacemaker, Artificial , Adult , Advisory Committees , Cardiac Resynchronization Therapy/adverse effects , Humans , Quality Indicators, Health Care
12.
Eur Heart J ; 42(35): 3529-3537, 2021 09 14.
Article in English | MEDLINE | ID: mdl-33954626

ABSTRACT

AIMS: Patients are restricted from driving following implantable cardioverter defibrillator (ICD) implantation or shock. We sought to investigate how many patients are aware of, and adhere to, the driving restrictions, and what proportion experience an ICD shock or other cardiac symptoms while driving. METHODS AND RESULTS: We performed a nationwide survey of all living Danish residents 18 years or older who received a first-time ICD between 2013 and 2016 (n = 3913) and linked their responses with nationwide registers. Of 2741 respondents (47% primary prevention, 83% male, median age 67 years), 2513 (92%) held a valid driver's license at ICD implantation, 175 (7%) of whom had a license for professional driving. Many drivers were unaware of driving restrictions: primary prevention 58%; secondary prevention 36%; post-appropriate shock 28%; professional drivers 55%. Almost all (94%) resumed non-professional driving after ICD implantation, more than one-third during the restricted period; 35% resumed professional driving. During a median follow-up of 2.3 years, 5 (0.2%) reported receiving an ICD shock while driving, one of which resulted in a traffic accident. The estimated risk of harm was 0.0002% per person-year. CONCLUSION: In this nationwide study, many ICD patients were unaware of driving restrictions, and more than one third resumed driving during a driving restriction period. However, the rate of reported ICD shocks while driving was very low.


Subject(s)
Automobile Driving , Defibrillators, Implantable , Accidents, Traffic , Aged , Death, Sudden, Cardiac , Female , Humans , Male , Primary Prevention , Surveys and Questionnaires
13.
J Cardiovasc Electrophysiol ; 32(8): 2295-2311, 2021 08.
Article in English | MEDLINE | ID: mdl-34091980

ABSTRACT

BACKGROUND: Patients receiving an implantable cardioverter defibrillator (ICD) generally adapt well to living with their device, but we know little about the prevalence of patients' body image concerns (BICs) postimplant. METHODS: The objectives were to evaluate the psychometric properties of the ICD-body image concerns questionnaire (BICQ), find a cut-off indicating BICs and determine the prevalence of BICs. Construct validity was determined using the Kaiser-Meyer-Olkin test, Scree-plot and explorative factor analysis. Internal consistency was examined via Cronbach's alpha. Correlations to other validated questionnaires, a weighted and simple scale and a cut-off indicating BICs was evaluated. RESULTS: In total, 331 patients completed the 39-item ICD-BICQ together with: Type D Scale (DS14), Generalized Anxiety Disorder scale (GAD-7), Patient Health Questionnaire (PHQ-9), and Florida Patient Acceptance Survey. Five patients were excluded due to reoperations, leaving 326 patients in the analyses. Results revealed a one-factor structure with 32 items and Cronbach's alpha at .948. A cut-off at 36 points displayed the 20% patients with the highest score of BICs. The prevalence was 29.8% in women and 18.4% in men. CONCLUSION: The psychometric evaluation of the 32-item ICD-BICQ showed acceptable construct validity and internal reliability. We recommend a cut-off score at 36 points to identify patients at risk of having BICs. The prevalence of BICs indicated that both men and women are at risk of having BICs. The ICD-BICQ can be used in clinical practice to help healthcare professionals to identify patients at risk of BICs and as to evaluate BICs when implementing new operation techniques.


Subject(s)
Body Image , Defibrillators, Implantable , Female , Humans , Male , Psychometrics , Reproducibility of Results , Surveys and Questionnaires
14.
J Cardiovasc Electrophysiol ; 32(7): 1947-1957, 2021 07.
Article in English | MEDLINE | ID: mdl-33928713

ABSTRACT

INTRODUCTION: MARVEL 2 assessed the efficacy of mechanical atrial sensing by a ventricular leadless pacemaker, enabling a VDD pacing mode. The behavior of the enhanced MARVEL 2 algorithm during variable atrio-ventricular conduction (AVC) and/or arrhythmias has not been characterized and is the focus of this study. METHODS: Of the 75 patients enrolled in the MARVEL 2 study, 73 had a rhythm assessment and were included in the analysis. The enhanced MARVEL 2 algorithm included a mode-switching algorithm that automatically switches between VDD and ventricular only antibradycardia pacing (VVI)-40 depending upon AVC status. RESULTS: Forty-two patients (58%) had persistent third degree AV block (AVB), 18 (25%) had 1:1 AVC, 5 (7%) had variable AVC status, and 8 (11%) had atrial arrhythmias. Among the 42 patients with persistent third degree AVB, the median ventricular pacing (VP) percentage was 99.9% compared to 0.2% among those with 1:1 AVC. As AVC status changed, the algorithm switched to VDD when the ventricular rate dropped less than 40 bpm. During atrial fibrillation (AF) with ventricular response greater than 40 bpm, VVI-40 mode was maintained. No pauses longer than 1500 ms were observed. Frequent ventricular premature beats reduced the percentage of AV synchrony. During AF, the atrial signal was of low amplitude and there was infrequent sensing. CONCLUSION: The mode switching algorithm reduced VP in patients with 1:1 AVC and appropriately switched to VDD during AV block. No pacing safety issues were observed during arrhythmias.


Subject(s)
Atrial Fibrillation , Atrioventricular Block , Pacemaker, Artificial , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Cardiac Pacing, Artificial , Heart Rate , Humans
15.
Europace ; 23(2): 163-173, 2021 02 05.
Article in English | MEDLINE | ID: mdl-33063088

ABSTRACT

Nearly one in ten patients experience complications in relation to cardiac implantable electronic device (CIED) implantations. CIED complications have serious implications for the patients and for the healthcare system. In light of the rising rates of new implants and consistent rate of complications, primary prevention remains a major concern. To guide future efforts, we sought to review the evidence base underlying common preventive actions made during a primary CIED implantation.


Subject(s)
Defibrillators, Implantable , Heart Diseases , Pacemaker, Artificial , Defibrillators, Implantable/adverse effects , Electronics , Humans , Pacemaker, Artificial/adverse effects , Postoperative Complications
16.
Europace ; 23(9): 1446-1455, 2021 09 08.
Article in English | MEDLINE | ID: mdl-33755136

ABSTRACT

AIM: The Prevention of Arrhythmia Device Infection Trial (PADIT) infection risk score, developed based on a large prospectively collected data set, identified five independent predictors of cardiac implantable electronic device (CIED) infection. We performed an independent validation of the risk score in a data set extracted from U.S. healthcare claims. METHODS AND RESULTS: Retrospective identification of index CIED procedures among patients aged ≥18 years with at least one record of a CIED procedure between January 2011 and September 2014 in a U.S health claims database. PADIT risk factors and major CIED infections (with system removal, invasive procedure without system removal, or infection-attributable death) were identified through diagnosis and procedure codes. The data set was randomized by PADIT score into Data Set A (60%) and Data Set B (40%). A frailty model allowing multiple procedures per patient was fit using Data Set A, with PADIT score as the only predictor, excluding patients with prior CIED infection. A data set of 54 042 index procedures among 51 623 patients with 574 infections was extracted. Among patients with no history of prior CIED infection, a 1 unit increase in the PADIT score was associated with a relative 28% increase in infection risk. Prior CIED infection was associated with significant incremental predictive value (HR 5.66, P < 0.0001) after adjusting for PADIT score. A Harrell's C-statistic for the PADIT score and history of prior CIED infection was 0.76. CONCLUSION: The PADIT risk score predicts increased CIED infection risk, identifying higher risk patients that could potentially benefit from targeted interventions to reduce the risk of CIED infection. Prior CIED infection confers incremental predictive value to the PADIT score.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Prosthesis-Related Infections , Adolescent , Adult , Arrhythmias, Cardiac/therapy , Defibrillators, Implantable/adverse effects , Delivery of Health Care , Electronics , Humans , Pacemaker, Artificial/adverse effects , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/prevention & control , Retrospective Studies , Risk Factors
17.
Indian Pacing Electrophysiol J ; 21(4): 209-218, 2021.
Article in English | MEDLINE | ID: mdl-33866018

ABSTRACT

BACKGROUND: In patients with cardiac resynchronization therapy defibrillators (CRT-Ds), intracardiac impedance measured by dedicated CRT-D software may be used to monitor hemodynamic changes. We investigated the relationship of hemodynamic parameters assessed by intracardiac impedance and by echocardiography in a controlled clinical setting. METHODS: The study enrolled 68 patients (mean age, 66 ± 9 years; 74% males) at 12 investigational sites. The patients had an indication for CRT-D implantation, New York Heart Association class II/III symptoms, left ventricular ejection fraction 15%-35%, and a QRS duration ≥150 ms. Two months after a CRT-D implantation, hemodynamic changes were provoked by overdrive pacing. Intracardiac impedance was recorded at rest and at four pacing rates ranging from 10 to 40 beats/min above the resting rate. In parallel, echocardiography measurements were performed. We hypothesized that a mean intra-individual correlation coefficient (rmean) between stroke impedance (difference between end-systolic and end-diastolic intracardiac impedance) measured by CRT-D and the aortic velocity time integral (i.e., stroke volume) determined by echocardiography would be significantly larger than 0.65. RESULTS: The hypothesis was evaluated in 40 patients with complete data sets. The rmean was 0.797, with a lower confidence interval bound of 0.709. The study hypothesis was met (p = 0.007). A stepwise reduction of stroke impedance and stroke volume was observed with increasing heart rate. CONCLUSIONS: Intracardiac impedance measured by implanted CRT-Ds correlated well with the aortic velocity time integral (stroke volume) determined by echocardiography. The impedance measurements bear potential and are readily available technically, not requiring implantation of additional material beyond standard CRT-D system.

18.
Europace ; 22(12): 1830-1840, 2020 12 23.
Article in English | MEDLINE | ID: mdl-33106878

ABSTRACT

AIMS: To investigate (i) the prevalence of anxiety and depression and (ii) the association between indication for implantable cardioverter-defibrillator (ICD) implantation and sex in relation to anxiety and depression up to 24 months' follow-up. METHODS AND RESULTS: Patients with a first-time ICD, participating in the national, multi-centre, prospective DEFIB-WOMEN study (n = 1496; 18% women) completed the Hospital Anxiety and Depression Scale at baseline, 3, 6, 12, and 24 months. Data were analysed using linear mixed modelling for longitudinal data. Patients with a secondary prophylactic indication (SPI) had higher mean anxiety scores than patients with a primary prophylactic indication (PPI) at baseline, 3, and 12 months and higher mean depression scores at all-time points, except at 24 months. Women had higher mean anxiety scores as compared to men at all-time points; however, only higher mean depression scores at baseline. Overall, women with SPI had higher anxiety and depression symptom scores than men with SPI. Symptoms decreased over time in both women and men. From baseline to follow-up, the prevalence of anxiety (score ≥8) was highest in patients with SPI (13.3-20.2%) as compared to patients with PPI (range 10.0-14.7%). The prevalence of depression was stable over the follow-up period in both groups (range 8.5-11.1%). CONCLUSION: Patients with a SPI reported higher anxiety and depression scores as compared to patients with PPI. Women reported higher anxiety scores than men, but only higher depression scores at baseline. Women with SPI reported the highest anxiety and depression scores overall.


Subject(s)
Defibrillators, Implantable , Anxiety/diagnosis , Anxiety/epidemiology , Denmark/epidemiology , Depression/diagnosis , Depression/epidemiology , Female , Follow-Up Studies , Humans , Male , Prevalence , Prospective Studies
19.
Europace ; 22(7): 1097-1102, 2020 07 01.
Article in English | MEDLINE | ID: mdl-32447372

ABSTRACT

AIMS: Commonly, a dysfunctional defibrillator lead is abandoned and a new lead is implanted. Long-term follow-up data on abandoned leads are sparse. We aimed to investigate the incidence and reasons for extraction of abandoned defibrillator leads in a nationwide cohort and to describe extraction procedure-related complications. METHODS AND RESULTS: All abandoned transvenous defibrillator leads were identified in the Danish Pacemaker and ICD Register from 1991 to 2019. The event-free survival of abandoned defibrillator leads was studied, and medical records of patients with interventions on abandoned defibrillator leads were audited for procedure-related data. We identified 740 abandoned defibrillator leads. Meantime from implantation to abandonment was 7.2 ± 3.8 years with mean patient age at abandonment of 66.5 ± 13.7 years. During a mean follow-up after abandonment of 4.4 ± 3.1 years, 65 (8.8%) abandoned defibrillator leads were extracted. Most frequent reason for extraction was infection (pocket and systemic) in 41 (63%) patients. Procedural outcome after lead extraction was clinical success in 63 (97%) patients. Minor complications occurred in 3 (5%) patients, and major complications in 1 (2%) patient. No patient died from complication to the procedure during 30-day follow-up after extraction. CONCLUSION: More than 90% of abandoned defibrillator leads do not need to be extracted during long-term follow-up. The most common indication for extraction is infection. Abandoned defibrillator leads can be extracted with high clinical success rate and low risk of major complications at high-volume centres.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Cohort Studies , Defibrillators, Implantable/adverse effects , Device Removal , Follow-Up Studies , Humans , Retrospective Studies , Treatment Outcome
20.
Eur Heart J ; 40(23): 1862-1869, 2019 06 14.
Article in English | MEDLINE | ID: mdl-31155647

ABSTRACT

AIMS: Device-related infection (DRI) is a severe complication to cardiac implantable electronic devices (CIED) therapy. Device-related infection incidence and its risk factors differ between previous studies. We aimed to define the long-term incidence and incidence rates of DRI for different types of CIEDs in the complete Danish device-cohort and identify patient-, operation- and device-related risk factors for DRI. METHODS AND RESULTS: From the Danish Pacemaker (PM) and implantable cardioverter-defibrillator (ICD) Register, we included consecutive Danish patients undergoing CIED implantation or reoperation from January 1982 to April 2018, resulting in 97 750 patients, 128 045 operations and follow-up of in total 566 275 device years (DY). We identified 1827 DRI causing device removals. Device-related infection incidence during device lifetime was 1.19% (1.12-1.26) for PM, 1.91% (1.71-2.13) for ICD, 2.18% (1.78-2.64) for cardiac resynchronization therapy (CRT)-pacemakers (CRT-P), and 3.35% (2.92-3.83) for CRT-defibrillators (CRT-D). Incidence rates in de novo implantations were 2.04/1000 DY for PM, 3.84 for ICD, 4.38 for CRT-P, and 6.76 for CRT-D. Using multiple-record and multiple-event per subject proportional hazard analysis, we identified implantation of complex devices (ICD and CRT), reoperations, prior DRI, male sex, and younger age as significantly associated with higher DRI risk. CONCLUSION: Overall risk of infection was low in PM implantations but considerably higher in CRT systems and after reinterventions. These data support the importance of evaluating all patients considered for CIED therapy thoroughly, in order to identify potential modifiable risk factors and reduce the risk of early reoperations.


Subject(s)
Defibrillators, Implantable/adverse effects , Pacemaker, Artificial/adverse effects , Prosthesis-Related Infections , Aged , Aged, 80 and over , Defibrillators, Implantable/statistics & numerical data , Denmark/epidemiology , Device Removal , Female , Humans , Incidence , Male , Middle Aged , Pacemaker, Artificial/statistics & numerical data , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/mortality , Retrospective Studies , Risk Factors