Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
Nano Lett ; 24(35): 10957-10963, 2024 Sep 04.
Article in English | MEDLINE | ID: mdl-39171725

ABSTRACT

Logic-in-memory (LIM) architecture holds great potential to break the von Neumann bottleneck. Despite the extensive research on novel devices, challenges persist in developing suitable engineering building blocks for such designs. Herein, we propose a reconfigurable strategy for efficient implementation of Boolean logics based on a hafnium oxide-based ferroelectric field effect transistor (HfO2-based FeFET). The logic results are stored within the device itself (in situ) during the computation process, featuring the key characteristics of LIM. The fast switching speed and low power consumption of a HfO2-based FeFET enable the execution of Boolean logics with an ultralow energy of lower than 8 attojoule (aJ). This represents a significant milestone in achieving aJ-level computing energy consumption. Furthermore, the system demonstrates exceptional reliability with computing endurance exceeding 108 cycles and retention properties exceeding 1000 s. These results highlight the remarkable potential of a FeFET for the realization of high performance beyond the von Neumann LIM computing architectures.

2.
Nano Lett ; 24(4): 1231-1237, 2024 Jan 31.
Article in English | MEDLINE | ID: mdl-38251914

ABSTRACT

Ferroelectricity, especially the Si-compatible type recently observed in hafnia-based materials, is technologically useful for modern memory and logic applications, but it is challenging to differentiate intrinsic ferroelectric polarization from the polar phase and oxygen vacancy. Here, we report electrically controllable ferroelectricity in a Hf0.5Zr0.5O2-based heterostructure with Sr-doped LaMnO3, a mixed ionic-electronic conductor, as an electrode. Electrically reversible extraction and insertion of an oxygen vacancy into Hf0.5Zr0.5O2 are macroscopically characterized and atomically imaged in situ. Utilizing this reversible process, we achieved multilevel polarization states modulated by the electric field. Our study demonstrates the usefulness of the mixed conductor to repair, create, manipulate, and utilize advanced ferroelectric functionality. Furthermore, the programmed ferroelectric heterostructures with Si-compatible doped hafnia are desirable for the development of future ferroelectric electronics.

3.
Sensors (Basel) ; 24(4)2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38400251

ABSTRACT

A surface-enhanced Raman scattering (SERS) method for measuring nitrate nitrogen in aquaculture water was developed using a substrate of ß-cyclodextrin-modified gold nanoparticles (SH-ß-CD@AuNPs). Addressing the issues of low sensitivity, narrow linear range, and relatively poor selectivity of single metal nanoparticles in the SERS detection of nitrate nitrogen, we combined metal nanoparticles with cyclodextrin supramolecular compounds to prepare a AuNPs substrate enveloped by cyclodextrin, which exhibits ultra-high selectivity and Raman activity. Subsequently, vanadium(III) chloride was used to convert nitrate ions into nitrite ions. The adsorption mechanism between the reaction product benzotriazole (BTAH) of o-phenylenediamine (OPD) and nitrite ions on the SH-ß-CD@AuNPs substrate was studied through SERS, achieving the simultaneous detection of nitrate nitrogen and nitrite nitrogen. The experimental results show that BTAH exhibits distinct SERS characteristic peaks at 1168, 1240, 1375, and 1600 cm-1, with the lowest detection limits of 3.33 × 10-2, 5.84 × 10-2, 2.40 × 10-2, and 1.05 × 10-2 µmol/L, respectively, and a linear range of 0.1-30.0 µmol/L. The proposed method provides an effective tool for the selective and accurate online detection of nitrite and nitrate nitrogen in aquaculture water.

4.
Sensors (Basel) ; 24(14)2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39065977

ABSTRACT

Wearable sensors, specifically microneedle sensors based on electrochemical methods, have expanded extensively with recent technological advances. Today's wearable electrochemical sensors present specific challenges: they show significant modulus disparities with skin tissue, implying possible discomfort in vivo, especially over extended wear periods or on sensitive skin areas. The sensors, primarily based on polyethylene terephthalate (PET) or polyimide (PI) substrates, might also cause pressure or unease during insertion due to the skin's irregular deformation. To address these constraints, we developed an innovative, wearable, all-fiber-structured electrochemical sensor. Our composite sensor incorporates polyurethane (PU) fibers prepared via electrospinning as electrode substrates to achieve excellent adaptability. Electrospun PU nanofiber films with gold layers shaped via thermal evaporation are used as base electrodes with exemplary conductivity and electrochemical catalytic attributes. To achieve glucose monitoring, gold nanofibers functionalized by gold nanoflakes (AuNFs) and glucose oxidase (GOx) serve as the working electrode, while Pt nanofibers and Ag/AgCl nanofibers serve as the counter and reference electrode. The acrylamide-sodium alginate double-network hydrogel synthesized on electrospun PU fibers serves as the adhesive and substance-transferring layer between the electrodes. The all-fiber electrochemical sensor is assembled layer-by-layer to form a robust structure. Given the stretchability of PU nanofibers coupled with a high specific surface area, the manufactured porous microneedle glucose sensor exhibits enhanced stretchability, superior sensitivity at 31.94 µA (lg(mM))-1 cm-2, a broad detection range (1-30 mM), and a significantly low detection limit (1 mM, S/N = 3), as well as satisfactory biocompatibility. Therefore, the novel electrochemical microneedle design is well-suited for wearable or even implantable continuous monitoring applications, thereby showing promising significant potential within the global arena of wearable medical technology.


Subject(s)
Biosensing Techniques , Nanofibers , Polyurethanes , Wearable Electronic Devices , Humans , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Polyurethanes/chemistry , Nanofibers/chemistry , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Electrodes , Gold/chemistry , Glucose Oxidase/chemistry , Glucose/analysis
5.
Sensors (Basel) ; 24(5)2024 Feb 25.
Article in English | MEDLINE | ID: mdl-38475029

ABSTRACT

In recent years, there has been a notable rise in the number of patients afflicted with laryngeal diseases, including cancer, trauma, and other ailments leading to voice loss. Currently, the market is witnessing a pressing demand for medical and healthcare products designed to assist individuals with voice defects, prompting the invention of the artificial throat (AT). This user-friendly device eliminates the need for complex procedures like phonation reconstruction surgery. Therefore, in this review, we will initially give a careful introduction to the intelligent AT, which can act not only as a sound sensor but also as a thin-film sound emitter. Then, the sensing principle to detect sound will be discussed carefully, including capacitive, piezoelectric, electromagnetic, and piezoresistive components employed in the realm of sound sensing. Following this, the development of thermoacoustic theory and different materials made of sound emitters will also be analyzed. After that, various algorithms utilized by the intelligent AT for speech pattern recognition will be reviewed, including some classical algorithms and neural network algorithms. Finally, the outlook, challenge, and conclusion of the intelligent AT will be stated. The intelligent AT presents clear advantages for patients with voice impairments, demonstrating significant social values.


Subject(s)
Pharynx , Voice , Humans , Sound , Algorithms , Neural Networks, Computer
6.
Adv Healthc Mater ; 13(22): e2400562, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38773929

ABSTRACT

The past few decades have witnessed the rapid advancement and broad applications of flexible bioelectronics, in wearable and implantable electronics, brain-computer interfaces, neural science and technology, clinical diagnosis, treatment, etc. It is noteworthy that soft and elastic conductive hydrogels, owing to their multiple similarities with biological tissues in terms of mechanics, electronics, water-rich, and biological functions, have successfully bridged the gap between rigid electronics and soft biology. Multifunctional hydrogel bioelectronics, emerging as a new generation of promising material candidates, have authentically established highly compatible and reliable, high-quality bioelectronic interfaces, particularly in bioelectronic recording and stimulation. This review summarizes the material basis and design principles involved in constructing hydrogel bioelectronic interfaces, and systematically discusses the fundamental mechanism and unique advantages in bioelectrical interfacing with the biological surface. Furthermore, an overview of the state-of-the-art manufacturing strategies for hydrogel bioelectronic interfaces with enhanced biocompatibility and integration with the biological system is presented. This review finally exemplifies the unprecedented advancement and impetus toward bioelectronic recording and stimulation, especially in implantable and integrated hydrogel bioelectronic systems, and concludes with a perspective expectation for hydrogel bioelectronics in clinical and biomedical applications.


Subject(s)
Electric Conductivity , Hydrogels , Hydrogels/chemistry , Humans , Wearable Electronic Devices , Biocompatible Materials/chemistry , Animals , Electronics
7.
Research (Wash D C) ; 7: 0424, 2024.
Article in English | MEDLINE | ID: mdl-39130493

ABSTRACT

Research on the flexible hybrid epidermal electronic system (FHEES) has attracted considerable attention due to its potential applications in human-machine interaction and healthcare. Through material and structural innovations, FHEES combines the advantages of traditional stiff electronic devices and flexible electronic technology, enabling it to be worn conformally on the skin while retaining complex system functionality. FHEESs use multimodal sensing to enhance the identification accuracy of the wearer's motion modes, intentions, or health status, thus realizing more comprehensive physiological signal acquisition. However, the heterogeneous integration of soft and stiff components makes balancing comfort and performance in designing and implementing multimodal FHEESs challenging. Herein, multimodal FHEESs are first introduced in 2 types based on their different system structure: all-in-one and assembled, reflecting totally different heterogeneous integration strategies. Characteristics and the key design issues (such as interconnect design, interface strategy, substrate selection, etc.) of the 2 multimodal FHEESs are emphasized. Besides, the applications and advantages of the 2 multimodal FHEESs in recent research have been presented, with a focus on the control and medical fields. Finally, the prospects and challenges of the multimodal FHEES are discussed.

8.
Sci Adv ; 10(37): eadp8681, 2024 Sep 13.
Article in English | MEDLINE | ID: mdl-39259789

ABSTRACT

The limitations and complexity of traditional noncontact sensors in terms of sensitivity and threshold settings pose great challenges to extend the traditional five human senses. Here, we propose tele-perception to enhance human perception and cognition beyond these conventional noncontact sensors. Our bionic multi-receptor skin employs structured doping of inorganic nanoparticles to enhance the local electric field, coupled with advanced deep learning algorithms, achieving a ΔV/Δd sensitivity of 14.2, surpassing benchmarks. This enables precise remote control of surveillance systems and robotic manipulators. Our long short-term memory-based adaptive pulse identification achieves 99.56% accuracy in material identification with accelerated processing speeds. In addition, we demonstrate the feasibility of using a two-dimensional (2D) sensor matrix to integrate real object scan data into a convolutional neural network to accurately discriminate the shape and material of 3D objects. This promises transformative advances in human-computer interaction and neuromorphic computing.


Subject(s)
Neural Networks, Computer , Humans , Skin , Deep Learning , Algorithms
9.
Sci Adv ; 10(36): eadp0174, 2024 Sep 06.
Article in English | MEDLINE | ID: mdl-39231224

ABSTRACT

Computing in memory (CIM) breaks the conventional von Neumann bottleneck through in situ processing. Monolithic integration of digital and analog CIM hardware, ensuring both high precision and energy efficiency, provides a sustainable paradigm for increasingly sophisticated artificial intelligence (AI) applications but remains challenging. Here, we propose a complementary metal-oxide semiconductor-compatible ferroelectric hybrid CIM platform that consists of Boolean logic and triggers for digital processing and multistage cell arrays for analog computation. The basic ferroelectric-gated units are assembled with solution-processable two-dimensional (2D) molybdenum disulfide atomic-thin channels at a wafer-scale yield of 96.36%, delivering high on/off ratios (>107), high endurance (>1012), long retention time (>10 years), and ultralow cycle-to-cycle/device-to-device variations (~0.3%/~0.5%). Last, we customize a highly compact 2D hybrid CIM system for dynamic tracking, achieving a high accuracy of 99.8% and a 263-fold improvement in power efficiency compared to graphics processing units. These results demonstrate the potential of 2D fully ferroelectric-gated hybrid hardware for developing versatile CIM blocks for AI tasks.

10.
Polymers (Basel) ; 15(12)2023 Jun 16.
Article in English | MEDLINE | ID: mdl-37376345

ABSTRACT

Spatial distribution perception has become an important trend for flexible pressure sensors, which endows wearable health devices, bionic robots, and human-machine interactive interfaces (HMI) with more precise tactile perception capabilities. Flexible pressure sensor arrays can monitor and extract abundant health information to assist in medical detection and diagnosis. Bionic robots and HMI with higher tactile perception abilities will maximize the freedom of human hands. Flexible arrays based on piezoresistive mechanisms have been extensively researched due to the high performance of pressure-sensing properties and simple readout principles. This review summarizes multiple considerations in the design of flexible piezoresistive arrays and recent advances in their development. First, frequently used piezoresistive materials and microstructures are introduced in which various strategies to improve sensor performance are presented. Second, pressure sensor arrays with spatial distribution perception capability are discussed emphatically. Crosstalk is a particular concern for sensor arrays, where mechanical and electrical sources of crosstalk issues and the corresponding solutions are highlighted. Third, several processing methods are also introduced, classified as printing, field-assisted and laser-assisted fabrication. Next, the representative application works of flexible piezoresistive arrays are provided, including human-interactive systems, healthcare devices, and some other scenarios. Finally, outlooks on the development of piezoresistive arrays are given.

11.
Materials (Basel) ; 16(17)2023 Aug 30.
Article in English | MEDLINE | ID: mdl-37687645

ABSTRACT

With the development of medical technology and increasing demands of healthcare monitoring, wearable temperature sensors have gained widespread attention because of their portability, flexibility, and capability of conducting real-time and continuous signal detection. To achieve excellent thermal sensitivity, high linearity, and a fast response time, the materials of sensors should be chosen carefully. Thus, reduced graphene oxide (rGO) has become one of the most popular materials for temperature sensors due to its exceptional thermal conductivity and sensitive resistance changes in response to different temperatures. Moreover, by using the corresponding preparation methods, rGO can be easily combined with various substrates, which has led to it being extensively applied in the wearable field. This paper reviews the state-of-the-art advances in wearable temperature sensors based on rGO films and summarizes their sensing mechanisms, structure designs, functional material additions, manufacturing processes, and performances. Finally, the possible challenges and prospects of rGO-based wearable temperature sensors are briefly discussed.

12.
Materials (Basel) ; 16(11)2023 May 24.
Article in English | MEDLINE | ID: mdl-37297066

ABSTRACT

As the focus on physical health increases, the market demand for flexible wearable sensors increases. Textiles combined with sensitive materials and electronic circuits can form flexible, breathable high-performance sensors for physiological-signal monitoring. Carbon-based materials such as graphene, carbon nanotubes (CNTs), and carbon black (CB) have been widely utilized in the development of flexible wearable sensors due to their high electrical conductivity, low toxicity, low mass density, and easy functionalization. This review provides an overview of recent advancements in carbon-based flexible textile sensors, highlighting the development, properties, and applications of graphene, CNTs, and CB for flexible textile sensors. The physiological signals that can be monitored by carbon-based textile sensors include electrocardiogram (ECG), human body movement, pulse and respiration, body temperature, and tactile perception. We categorize and describe carbon-based textile sensors based on the physiological signals they monitor. Finally, we discuss the current challenges associated with carbon-based textile sensors and explore the future direction of textile sensors for monitoring physiological signals.

13.
Materials (Basel) ; 16(6)2023 Mar 07.
Article in English | MEDLINE | ID: mdl-36984013

ABSTRACT

Continuous blood pressure (BP) monitoring is of great significance for the real-time monitoring and early prevention of cardiovascular diseases. Recently, wearable BP monitoring devices have made great progress in the development of daily BP monitoring because they adapt to long-term and high-comfort wear requirements. However, the research and development of wearable continuous BP monitoring devices still face great challenges such as obvious motion noise and slow dynamic response speeds. The pulse wave transit time method which is combined with photoplethysmography (PPG) waves and electrocardiogram (ECG) waves for continuous BP monitoring has received wide attention due to its advantages in terms of excellent dynamic response characteristics and high accuracy. Here, we review the recent state-of-art wearable continuous BP monitoring devices and related technology based on the pulse wave transit time; their measuring principles, design methods, preparation processes, and properties are analyzed in detail. In addition, the potential development directions and challenges of wearable continuous BP monitoring devices based on the pulse wave transit time method are discussed.

14.
Adv Sci (Weinh) ; 10(34): e2303734, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37814361

ABSTRACT

Two-dimensional material-based field-effect transistors (2DM-FETs) are playing a revolutionary role in electronic devices. However, before electronic design automation (EDA) for 2DM-FETs can be achieved, it remains necessary to determine how to incorporate contact transports into model. Reported methods compromise between physical intelligibility and model compactness due to the heterojunction nature. To address this, quasi-Fermi-level phase space theory (QFLPS) is generalized to incorporate contact transports using the Landauer formula. It turns out that the Landauer-QFLPS model effectively overcomes the issue of concern. The proposed new formula can describe 2DM-FETs with Schottky or Ohmic contacts with superior accuracy and efficiency over previous methods, especially when describing non-monotonic drain conductance characteristics. A three-bit threshold inverter quantizer (TIQ) circuit is fabricated using ambipolar black phosphorus and it is demonstrated that the model accurately predicts circuit performance. The model could be very effective and valuable in the development of 2DM-FET-based integrated circuits.

15.
J Cosmet Dermatol ; 21(12): 6742-6753, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36038248

ABSTRACT

OBJECTIVE: This study aimed to analyze the clinical results and influencing factors of the fractional microneedle radiofrequency (FMR) treatment for enlarged facial pores on different facial sites. METHODS: The clinical data of patients with enlarged facial pores who underwent FMR treatment from January 2019 to December 2020 were collected. The efficacy and complications of FMR for enlarged pores in different facial areas were retrospectively analyzed. Univariate and multivariate logistic regression analyses were used to explore the clinical factors related to the efficacy of FMR after the first treatment session. RESULTS: Totally, 75 patients with enlarged facial pores were included (full-face FMR for 45, nasal FMR for 58, frontal FMR for 45, and cheek FMR for 72 patients). All patients received more than one treatment session, two patients received five treatment sessions, and the mean number of FMR session was 1.7. The moderate to excellent improvement rates in patients with nasal, frontal and cheek enlarged pores after the first session were 13.8%, 8.9%, and 11.1%, respectively. The improvement rate rose with the increasing number of treatment sessions. Multivariate logistic regression analysis revealed that long pulse-width (300 ms) was positively associated with clinical efficacy after the first session (OR = 22.4, 95% CI [2.0-250.4], p = 0.012), compared with the short pulse-width group (100-200 ms). The main adverse effects after FMR were transient pain, erythema, and edema. A minority of patients developed acneiform eruption. CONCLUSION: This study confirms that FMR is safe and effective in improving enlarged facial pores. The pulse width is associated with the improvement of nasal enlarged pores.


Subject(s)
Acne Vulgaris , Radiofrequency Therapy , Humans , Acne Vulgaris/complications , Retrospective Studies , Treatment Outcome , Erythema/etiology
16.
J Cosmet Dermatol ; 21(5): 1989-1997, 2022 May.
Article in English | MEDLINE | ID: mdl-35181995

ABSTRACT

OBJECTIVE: This study was performed to analyze the efficacy, adverse reactions of fractional CO2  laser for atrophic acne scars, and related clinical factors. METHODS: The clinical data of 121 patients with atrophic acne scars treated with ultra-pulsed fractional CO2  laser in the Cosmetic Dermatology from August 2014 to March 2020 were retrospectively analyzed. The efficacy and adverse reactions of atrophic acne scar after fractional CO2  laser therapy were statistically analyzed. The clinical factors related to efficacy and adverse reactions after the first therapy session were analyzed by multivariate logistic regression. RESULTS: A total of 121 patients received 206 sessions of fractional CO2  laser therapy, with an average of 1.7 sessions. Moderate to excellent improvement rate reached 50.4% after the first session. Multivariate logistic regression analysis indicated that rolling scars responded better to fractional CO2  laser treatment than icepick scars (OR = 7.3, 95% CI [1.2, 43.4], p = 0.029), and scar improvement was more significant in the high-energy laser group than in the low-energy laser group (OR = 10.9, 95% CI [1.1, 106.8], p = 0.041). The main adverse reactions after fractional laser surgery were pigmentation, skin sensitivity, persistent erythema, and acneiform eruption. Multivariate logistic analysis revealed that the longer the scar duration, the higher incidence of postoperative adverse reactions (OR = 1.3, 95% CI [1.1, 1.5], p = 0.008). Compared with icepick scars, rolling scars (OR = 10.4, 95% CI [2.3, 47.7], p = 0.003) and boxcar scars (OR = 12.0, 95% CI [3.3, 44.0], p < 0.001) had higher risk of developing adverse reactions. The incidence of postoperative adverse reactions was also higher in the combined mode group (DeepFX mode + ActiveFX mode) than in the single-mode group (OR = 7.8, 95% CI [2.4, 25.5], p < 0.001). CONCLUSION: Fractional CO2 laser was effective in the treatment of atrophic acne scars, without serious adverse reactions. Scar type and laser energy were independent clinical factors affecting its efficacy. Scar course, scar type, and fractional laser mode were independent clinical factors affecting its adverse reactions.


Subject(s)
Acne Vulgaris , Laser Therapy , Lasers, Gas , Acne Vulgaris/complications , Atrophy/complications , Atrophy/surgery , Carbon Dioxide , Cicatrix/etiology , Cicatrix/pathology , Cicatrix/surgery , Humans , Laser Therapy/adverse effects , Lasers, Gas/adverse effects , Retrospective Studies , Treatment Outcome
17.
Nanomicro Lett ; 14(1): 161, 2022 Aug 09.
Article in English | MEDLINE | ID: mdl-35943631

ABSTRACT

With the aging of society and the increase in people's concern for personal health, long-term physiological signal monitoring in daily life is in demand. In recent years, electronic skin (e-skin) for daily health monitoring applications has achieved rapid development due to its advantages in high-quality physiological signals monitoring and suitability for system integrations. Among them, the breathable e-skin has developed rapidly in recent years because it adapts to the long-term and high-comfort wear requirements of monitoring physiological signals in daily life. In this review, the recent achievements of breathable e-skins for daily physiological monitoring are systematically introduced and discussed. By dividing them into breathable e-skin electrodes, breathable e-skin sensors, and breathable e-skin systems, we sort out their design ideas, manufacturing processes, performances, and applications and show their advantages in long-term physiological signal monitoring in daily life. In addition, the development directions and challenges of the breathable e-skin are discussed and prospected.

18.
Adv Sci (Weinh) ; 7(19): 2001266, 2020 Oct.
Article in English | MEDLINE | ID: mdl-33042746

ABSTRACT

Ferroelectric memories with ultralow-power-consumption are attracting a great deal of interest with the ever-increasing demand for information storage in wearable electronics. However, sufficient scalability, semiconducting compatibility, and robust flexibility of the ferroelectric memories remain great challenges, e.g., owing to Pb-containing materials, oxide electrode, and limited thermal stability. Here, high-performance flexible nonvolatile memories based on ferroelectric Hf0.5Zr0.5O2 (HZO) via quasi-van der Waals heteroepitaxy are reported. The flexible ferroelectric HZO exhibits not only high remanent polarization up to 32.6 µC cm-2 without a wake-up effect during cycling, but also remarkably robust mechanical properties, degradation-free retention, and endurance performance under a series of bent deformations and cycling tests. Intriguingly, using HZO as a gate, flexible ferroelectric thin-film transistors with a low operating voltage of ±3 V, high on/off ratio of 6.5 × 105, and a small subthreshold slope of about 100 mV dec-1, which outperform reported flexible ferroelectric transistors, are demonstrated. The results make ferroelectric HZO a promising candidate for the next-generation of wearable, low-power, and nonvolatile memories with manufacturability and scalability.

19.
Medicine (Baltimore) ; 98(32): e16362, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31393345

ABSTRACT

RATIONALE: Atopic dermatitis (AD) is a chronic recurrent dermatitis with profound itching, which could be the first manifestation of acute myeloid leukemia (AML). PATIENT CONCERNS: A 53-year-old Chinese man suffered a 6-month history of systemic symmetrical dermatitis, accompanied with profound itching. The patient was diagnosed as "eczema" in several hospitals, and the effects of antihistamine and topical steroid creams were poor. Nocturnal sleep was seriously affected by aggravating pruritus. Laboratorial examination was compatible with AML-M4. DIAGNOSES: AML-M4 with AD as first manifestation. INTERVENTIONS: IA regimen (ayninen and cytarabine) were used in induction chemotherapy. However, the patient did not achieve complete remission, and although his rash had improved, he still experienced severely general body itching. On the seventh day of chemotherapy, the patient entered the period of granulocyte deficiency with infection. OUTCOMES: The patient died due to septic shock after chemotherapy. LESSONS: The case strengthens the awareness of AML with AD as first manifestation and raises oncological vigilance in patients with AD refractory.


Subject(s)
Dermatitis, Atopic/etiology , Leukemia, Myeloid, Acute/complications , Leukemia, Myeloid, Acute/diagnosis , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Dermatitis, Atopic/drug therapy , Humans , Leukemia, Myeloid, Acute/drug therapy , Leukemia, Myeloid, Acute/physiopathology , Male , Middle Aged
20.
Medicine (Baltimore) ; 98(48): e17948, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31770202

ABSTRACT

BACKGROUND: Laser systems are a common treatment choice for onychomycosis. They exert their effects on inhibiting the growth of the fungus by selective photothermolysis but efficacy is dependent on the specific type of apparatus used. To systematically review the available published literature on the curative effects and safety of laser treatment for onychomycosis. METHODS: Databases including PubMed, web of science, China National Knowledge Internet (CNKI), WanFang Database and VIP were searched systematically to identify relevant articles published up to July 2018. Potentially relevant articles were sourced, assessed against eligibility criteria by 2 researchers independently and data were extracted from included studies. A meta-analysis was performed using R software. RESULTS: Thirty-five articles involving 1723 patients and 4278 infected nails were included. Meta-analysis of data extracted from these studies revealed that: the overall mycological cure rate was 63.0% (95%CI 0.53-0.73); the mycological cure rate associated with the 1064-nm Nd: YAG laser was 63.0% (95%CI 0.51-0.74); and that of CO2 lasers was 74.0% (95%CI 0.37-0.98). The published data indicate that laser treatment is relatively safe, but can cause tolerable pain and occasionally lead to bleeding after treatment. CONCLUSION: Laser treatment of onychomycosis is effective and safe. The cumulative cure rate of laser treatment was significantly higher for CO2 lasers than other types of laser. Laser practitioners should be made aware of potential adverse effects such as pain and bleeding.


Subject(s)
Lasers, Gas/therapeutic use , Lasers, Solid-State/therapeutic use , Low-Level Light Therapy/methods , Onychomycosis/radiotherapy , Humans , Nails/radiation effects , Randomized Controlled Trials as Topic , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL