Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Pak J Pharm Sci ; 34(3): 835-841, 2021 May.
Article in English | MEDLINE | ID: mdl-34602404

ABSTRACT

A highly sensitive liquid chromatographic method with UV detection has been developed for simultaneous determination of citalopram, levocetirizine and loratadine in bulk drug, pharmaceutical formulation and human serum at 230nm employing 80:20 v/v methanol-water as mobile phase with pH3.5, adjusting flow rate of 1.0mL.min-1. Separation was achieved on Shimadzu Shim-pack CLC-ODS (M) 25M column within the linear range of 0.4-12.5, 0.8-25 and 0.8-25µg.mL-1 with R2 >0.998 and detection limit 7.75, 3.35 and 10.26ng.mL-1respectively. ICH guidelines were followed for validation showing 0.22-1.76, 0.06-1.83 and 0.22-2.11% RSD. The recovery of analytes in tablets and serum was found to be in acceptable range. The method was fruitfully employed for the determination of studied analyte in pharmaceutical formulation and human serum.


Subject(s)
Cetirizine/analysis , Chromatography, High Pressure Liquid/methods , Citalopram/analysis , Loratadine/analysis , Cetirizine/blood , Citalopram/blood , Humans , Loratadine/blood , Reproducibility of Results
2.
Pak J Pharm Sci ; 33(1): 121-127, 2020 Jan.
Article in English | MEDLINE | ID: mdl-32122839

ABSTRACT

High performance liquid chromatography with UV/vis detection was optimized and validated for simultaneous quantification of alprazolam with celecoxib and diclofenac sodium in pharmaceutical formulation and human serum. Chromatographic separation was achieved at detection wavelength of 230 nm on Shimadzu Shim-pack CLC-ODS (M) 25M column employing 80:20 (v/v) methanol: water (pH 3.5) as mobile phase with elution rate 1.0mL min-1. Analytes were quantified in the ranges 0.2-15, 0.3-20 and 0.6-40 µg mL-1 with detection limits 19.76, 17.29 and 11.83ng mL-1 respectively. Recoveries were in the range 98.15-101.15, 99.24-99.90 and 98.87-101.19% in pharmaceutical formulation and 98.05-101.01, 98.72-99.49 and 98.25-99.47% in human serum respectively and precision ranged from 0.19-1.84%. The analytes were successfully detected without any observable interference commonly present in pharmaceutical formulation and human serum demonstrating applicability of method.


Subject(s)
Alprazolam/analysis , Alprazolam/blood , Celecoxib/analysis , Celecoxib/blood , Chromatography, High Pressure Liquid/methods , Diclofenac/blood , Tablets/chemistry , Diclofenac/analysis , Humans , Limit of Detection
SELECTION OF CITATIONS
SEARCH DETAIL