Anal Biochem ; 551: 4-6, 2018 06 15.
Article in English | MEDLINE | ID: mdl-29680224

ABSTRACT

Rapid molecular diagnostic testing for respiratory infections can improve patient care and minimize unnecessary prescriptions of antibiotics. We present the preliminary clinical evaluation of Orion GenRead® RSV, a novel, rapid, and easy-to-use molecular test for the diagnosis of respiratory syncytial virus (RSV) infection. The sensitivity and specificity of Orion GenRead RSV were 99% and 100%, respectively. Orion GenRead RSV detected RSV-positive specimens within 15 min. The performance of Orion GenRead RSV was similar to that of the reference method and this test could rapidly detect RSV within minutes. Orion GenRead RSV is applicable for near-patient testing.


Subject(s)
Molecular Diagnostic Techniques/methods , Respiratory Syncytial Virus Infections/diagnosis , Respiratory Syncytial Virus, Human/genetics , Respiratory Syncytial Virus, Human/isolation & purification , Respiratory Tract Infections/diagnosis , Humans , Molecular Diagnostic Techniques/statistics & numerical data , Nasopharynx/virology , Nucleic Acid Amplification Techniques/methods , Nucleic Acid Amplification Techniques/statistics & numerical data , Respiratory Syncytial Virus Infections/virology , Respiratory Tract Infections/virology , Time Factors
2.
Appl Microbiol Biotechnol ; 100(12): 5559-67, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27063012

ABSTRACT

Rapid and accurate diagnosis of influenza viruses plays an important role in infection control, as well as in preventing the misuse of antibiotics. Isothermal nucleic acid amplification methods offer significant advantages over the polymerase chain reaction (PCR), since they are more rapid and do not require the sophisticated instruments needed for thermal cycling. We previously described a novel isothermal nucleic acid amplification method, 'Strand Invasion Based Amplification' (SIBA®), with high analytical sensitivity and specificity, for the detection of DNA. In this study, we describe the development of a variant of the SIBA method, namely, reverse transcription SIBA (RT-SIBA), for the rapid detection of viral RNA targets. The RT-SIBA method includes a reverse transcriptase enzyme that allows one-step reverse transcription of RNA to complementary DNA (cDNA) and simultaneous amplification and detection of the cDNA by SIBA under isothermal reaction conditions. The RT-SIBA method was found to be more sensitive than PCR for the detection of influenza A and B and could detect 100 copies of influenza RNA within 15 min. The development of RT-SIBA will enable rapid and accurate diagnosis of viral RNA targets within point-of-care or central laboratory settings.


Subject(s)
Influenza A virus/isolation & purification , Influenza B virus/isolation & purification , Influenza, Human/diagnosis , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques , Reverse Transcription , DNA Primers , Humans , Influenza A virus/genetics , Influenza B virus/genetics , Point-of-Care Systems , RNA, Viral/genetics , Sensitivity and Specificity
3.
Biomicrofluidics ; 18(1): 014106, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38420041

ABSTRACT

Droplet digital PCR (ddPCR) is a technique in which PCR reaction is divided into thousands of nanoliter-sized droplets and has proven to be a great tool in virus diagnostics. Compared to the gold standard system quantitative real-time PCR (RT-qPCR), ddPCR functions particularly well when dealing with samples with low template counts, such as viral concentration. This feature makes the technique suitable for early detection of the virus. In this study, a novel portable PDMS ddPCR chip is introduced. The chip functions without external pumps using manual pressurization with a multichannel pipet. The created droplets are monodispersed and form a monolayer on the chip's collection chamber, from where they can be effortlessly imaged. Droplets were analyzed and counted using artificial intelligence. The use of the manually pressurized chip was demonstrated for a SARS-CoV-2 assay, which takes advantage of isothermal strand invasion-based amplification (SIBA) technology, allowing quick and accurate, even point-of-care analysis of the sample. The results demonstrate that SIBA assays can be divided into nanoliter-sized droplets and used as quantitative assays, giving an approximation of the samples' viral count.

4.
Sci Rep ; 11(1): 22214, 2021 11 15.
Article in English | MEDLINE | ID: mdl-34782681

ABSTRACT

Rapid nucleic-acid based tests that can be performed by non-professionals outside laboratory settings could help the containment of the pandemic SARS-CoV-2 virus and may potentially prevent further widespread lockdowns. Here, we present a novel compact portable detection instrument (the Egoo Health System) for extraction-free detection of SARS-CoV-2 using isothermal reverse transcription strand invasion based amplification (RT-SIBA). The SARS-CoV-2 RT-SIBA assay can be performed directly on crude oropharyngeal swabs without nucleic acid extraction with a reaction time of 30 min. The Egoo Health system uses a capsule system, which is automatically sealed tight in the Egoo instrument after applying the sample, resulting in a closed system optimal for molecular isothermal amplification. The performance of the Egoo Health System is comparable to the PCR instrument with an analytical sensitivity of 25 viral RNA copies per SARS-CoV-2 RT-SIBA reaction and a clinical sensitivity and specificity between 87.0-98.4% and 96.6-98.2% respectively.


Subject(s)
COVID-19/diagnosis , COVID-19/epidemiology , Equipment Design , Molecular Diagnostic Techniques/instrumentation , Molecular Diagnostic Techniques/methods , Pandemics/prevention & control , Reverse Transcriptase Polymerase Chain Reaction/instrumentation , Reverse Transcriptase Polymerase Chain Reaction/methods , SARS-CoV-2/genetics , COVID-19/virology , Cell Phone , Humans , Mobile Applications , Oropharynx/virology , Point-of-Care Testing , Polymorphism, Single Nucleotide , RNA, Viral/genetics , Retrospective Studies , Sensitivity and Specificity
5.
Diagn Microbiol Infect Dis ; 86(4): 369-371, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27645608

ABSTRACT

Zika virus has only recently gained attention due to recent large outbreaks worldwide. An easy to use nucleic acid amplification test could play an important role in the early detection of the infection and patient management. Here, we report a rapid and robust isothermal nucleic acid amplification assay for the detection of Zika virus. The method is cost-effective and compatible with portable instrumentation, enabling near patient testing and field use.


Subject(s)
Molecular Diagnostic Techniques/methods , Nucleic Acid Amplification Techniques/methods , Zika Virus Infection/diagnosis , Zika Virus/isolation & purification , Cost-Benefit Analysis , Humans , Time Factors , Zika Virus/genetics
6.
BMC Res Notes ; 9: 389, 2016 Aug 04.
Article in English | MEDLINE | ID: mdl-27488131

ABSTRACT

BACKGROUND: Staphylococcus aureus is a versatile pathogen expressing a number of virulence-associated adhesive molecules. In a previous study, we generated in a secretion-competent Escherichia coli strain a library of random FLAG-tag positive (FTP) polypeptides of S. aureus. To identify adhesive proteins and gain additional knowledge on putative virulence factors of S. aureus, we here screened the FTP library against human serum proteins. FINDINGS: Staphylococcus aureus NCTC 8325-4, origin of the FTP library, adhered to immobilized plasminogen in vitro. In an enzyme-linked immunoassay a C-terminal part of penicillin binding protein 3 (PBP3), included in the FTP library, bound to immobilized plasminogen. We expressed and purified full-length PBP3 and its C-terminal fragments as recombinant proteins. In a time-resolved fluorometry-based assay the PBP3 polypeptides bound to immobilized plasminogen. The polypeptides enhanced formation of plasmin from plasminogen as analyzed by cleavage of a chromogenic plasmin substrate. CONCLUSIONS: The present findings, although preliminary, demonstrate reliably that S. aureus NCTC 8325-4 adheres to immobilized plasminogen in vitro and that the adhesion may be mediated by a C-terminal fragment of the PBP3 protein. The full length PBP3 and the penicillin binding C-terminal domain of PBP3 expressed as recombinant proteins bound plasminogen and activated plasminogen to plasmin. These phenomena were inhibited by the lysine analogue ε-aminocaproic acid suggesting that the binding is mediated by lysine residues. A detailed molecular description of surface molecules enhancing the virulence of S. aureus will aid in understanding of its pathogenicity and help in design of antibacterial drugs in the future.


Subject(s)