Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
J Clin Med ; 13(8)2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38673631

ABSTRACT

Background: In this study, we aimed to compare the effects of conventional and digital impressions on several parameters (inter-implant distance, intra-implant distance, inter-implant axis, and intra-implant axis) of three implants in curved lines and straight lines by using a laboratory scanner (LBS) versus an intra-oral scanner (IOS). Methods: Two 3D models were fabricated using a printer, each model with three internal hex implants analogues at the positions of 15#,16#,17# (straight line) and 12#,13#,14# (curved line). Standard intra-oral scan bodies (ISBs) were used, and the two models were scanned using 7 Series dental wings (LBS, reference model), followed by ten scans with Primescan (digital method). Standard Tessellation Language (STL) files were created. Five polyether impressions were taken from each model (straight and curved), and gypsum type 4 models were poured; each model was scanned five times to create a total of 25 STL files for each group (conventional method). The comparison between all the STL files (conventional and digital) was made by superimposition of the STL files on the STL reference model laboratory file using a 3D analyzing software. A Kolmogorov-Smirnov test was performed, followed by Mann-Whitney tests and Wilcoxon signed-rank tests. (p < 0.05). Results: For the conventional method, the mean errors were significantly higher for the curved line model (12-14) compared to the straight line model (15-17) for most parameters (p < 0.05). For the digital method, the mean errors were significantly higher for the curved-line model (12-14) compared to the straight line model (15-17) in half of the parameters (p < 0.05). Within the curved line model (12-14) and the straight line model (15-17), the mean errors between the conventional method and the digital method were not significant for most variables. Conclusions: The difference between curved lines and straight lines has an impact on the mean error of the conventional method. Both methods are reliable for straight and curved lines in partially dentate situations.

2.
Int J Dent ; 2024: 9688717, 2024.
Article in English | MEDLINE | ID: mdl-39206224

ABSTRACT

Background: The aim of this study was to evaluate the changing levels of stress among dental students during 8 months of a basic manual skills course in the preclinical year and to examine the association between stress and dental performance. Methods: A longitudinal study was conducted in the 2023 academic year in a total of 58 (male = 17 and female = 41; mean age = 26.43, range 22-33) undergraduate dental students at Tel Aviv University of dentistry during their fourth year of study. Depression Anxiety Stress Scale (DASS-21) and Dental Environment Stress (DES) questionnaires were used to assess the psychological well-being and the severity of DASS symptoms experienced by the students. The students' dental performances were assessed using two manual tests on plastic teeth. The questionnaires and the manual tests were used at three periods of time, T0, T1, and T2. Wilcoxon signed-rank tests were performed to compare the DASS scores and DES stressors of dental students between T0, T1, and T2. Kendall's nonparametric correlations were calculated to investigate the relationships of DES stressors and depression, anxiety, and stress scores with manual performance. Conclusions: The perception of high stress by dental students is due to the stressful education process of the preclinical year. There is an inverse correlation between the lower level of anxiety and the increase level of dental performance with 74% of the variance in dental performance explained by the anxiety score. Work-related stressors such as manual skills might reduce dental performance in contrast to non-work-related factors such as financial obligations, personal issues, and family factors, which might increase student dental performance.

3.
J Clin Med ; 12(20)2023 Oct 20.
Article in English | MEDLINE | ID: mdl-37892783

ABSTRACT

BACKGROUND: The purpose of this in vitro study was to compare the inter-implant distance, inter-implant axis, and intra-implant axis of three implants in a straight line by using a laboratory scanner (LBS) versus an intra-oral scanner (IOS) with two different intra-oral scan bodies (ISBs). METHODS: A 3D model was printed with internal hex implant analogs of three implants in positions 15#, 16#, and 17#. Two standard intra-oral scan bodies (ISBs) were used: MIS ISB (two-piece titanium) and Zirkonzhan ISB (two-piece titanium). Both ISBs were scanned using 7 Series dental wings (LBS) and 30 times using Primescan (IOS). For each scan, a stereolithography (STL) file was created and a comparison between all the scans was performed through superimposition of the STL files by using 3D analysis software (PolyWorks® 2020; InnovMetric, Québec, QC, Canada). A Kolmogorov-Smirnov test was performed followed by a Mann-Whitney test (p < 0.05). RESULTS: The change in inter-implant distance for the MIS ISB was significantly lower compared to the ZZ (p < 0.05). The change in intra-implant angle was significantly lower for the ZZ ISB compared to MIS (p < 0.05). The changes in inter-implant angle between the mesial and middle and between the middle and distal were significantly lower for MIS compared to ZZ in contrast to mesial to distal, which was significantly higher (p < 0.05). CONCLUSIONS: Both ISBs showed differences in all the parameters between the LBS and the IOS. The geometry of the scan abutment had an impact on the inter-implant distance as the changes in the inter-implant distance were significantly lower for the MIS ISB. The changes in the intra-implant angle were significantly lower for the ZZ ISB. There is a need for further research examining the influence of geometry, material, and scan abutment parts on the trueness.

SELECTION OF CITATIONS
SEARCH DETAIL