N Engl J Med ; 389(13): 1167-1179, 2023 Sep 28.
Article in English | MEDLINE | ID: mdl-37622677

ABSTRACT

BACKGROUND: Device-detected atrial high-rate episodes (AHREs) are atrial arrhythmias detected by implanted cardiac devices. AHREs resemble atrial fibrillation but are rare and brief. Whether the occurrence of AHREs in patients without atrial fibrillation (as documented on a conventional electrocardiogram [ECG]) justifies the initiation of anticoagulants is not known. METHODS: We conducted an event-driven, double-blind, double-dummy, randomized trial involving patients 65 years of age or older who had AHREs lasting for at least 6 minutes and who had at least one additional risk factor for stroke. Patients were randomly assigned in a 1:1 ratio to receive edoxaban or placebo. The primary efficacy outcome was a composite of cardiovascular death, stroke, or systemic embolism, evaluated in a time-to-event analysis. The safety outcome was a composite of death from any cause or major bleeding. RESULTS: The analysis population consisted of 2536 patients (1270 in the edoxaban group and 1266 in the placebo group). The mean age was 78 years, 37.4% were women, and the median duration of AHREs was 2.8 hours. The trial was terminated early, at a median follow-up of 21 months, on the basis of safety concerns and the results of an independent, informal assessment of futility for the efficacy of edoxaban; at termination, the planned enrollment had been completed. A primary efficacy outcome event occurred in 83 patients (3.2% per patient-year) in the edoxaban group and in 101 patients (4.0% per patient-year) in the placebo group (hazard ratio, 0.81; 95% confidence interval [CI], 0.60 to 1.08; P = 0.15). The incidence of stroke was approximately 1% per patient-year in both groups. A safety outcome event occurred in 149 patients (5.9% per patient-year) in the edoxaban group and in 114 patients (4.5% per patient-year) in the placebo group (hazard ratio, 1.31; 95% CI, 1.02 to 1.67; P = 0.03). ECG-diagnosed atrial fibrillation developed in 462 of 2536 patients (18.2% total, 8.7% per patient-year). CONCLUSIONS: Among patients with AHREs detected by implantable devices, anticoagulation with edoxaban did not significantly reduce the incidence of a composite of cardiovascular death, stroke, or systemic embolism as compared with placebo, but it led to a higher incidence of a composite of death or major bleeding. The incidence of stroke was low in both groups. (Funded by the German Center for Cardiovascular Research and others; NOAH-AFNET 6 ClinicalTrials.gov number, NCT02618577; ISRCTN number, ISRCTN17309850.).


Subject(s)
Anticoagulants , Arrhythmias, Cardiac , Embolism , Factor Xa Inhibitors , Aged , Female , Humans , Male , Anticoagulants/adverse effects , Anticoagulants/therapeutic use , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Embolism/drug therapy , Embolism/etiology , Factor Xa Inhibitors/adverse effects , Factor Xa Inhibitors/therapeutic use , Hemorrhage/chemically induced , Stroke/etiology , Stroke/prevention & control , Electrodes, Implanted , Double-Blind Method , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/diagnosis , Risk Factors
2.
Eur Heart J ; 45(10): 837-849, 2024 Mar 07.
Article in English | MEDLINE | ID: mdl-37956458

ABSTRACT

BACKGROUND AND AIMS: Patients with long atrial high-rate episodes (AHREs) ≥24 h and stroke risk factors are often treated with anticoagulation for stroke prevention. Anticoagulation has never been compared with no anticoagulation in these patients. METHODS: This secondary pre-specified analysis of the Non-vitamin K antagonist Oral anticoagulants in patients with Atrial High-rate episodes (NOAH-AFNET 6) trial examined interactions between AHRE duration at baseline and anticoagulation with edoxaban compared with placebo in patients with AHRE and stroke risk factors. The primary efficacy outcome was a composite of stroke, systemic embolism, or cardiovascular death. The safety outcome was a composite of major bleeding and death. Key secondary outcomes were components of these outcomes and electrocardiogram (ECG)-diagnosed atrial fibrillation. RESULTS: Median follow-up of 2389 patients with core lab-verified AHRE was 1.8 years. AHRE ≥24 h were present at baseline in 259/2389 patients (11%, 78 ± 7 years old, 28% women, CHA2DS2-VASc 4). Clinical characteristics were not different from patients with shorter AHRE. The primary outcome occurred in 9/132 patients with AHRE ≥24 h (4.3%/patient-year, 2 strokes) treated with anticoagulation and in 14/127 patients treated with placebo (6.9%/patient-year, 2 strokes). Atrial high-rate episode duration did not interact with the efficacy (P-interaction = .65) or safety (P-interaction = .98) of anticoagulation. Analyses including AHRE as a continuous parameter confirmed this. Patients with AHRE ≥24 h developed more ECG-diagnosed atrial fibrillation (17.0%/patient-year) than patients with shorter AHRE (8.2%/patient-year; P < .001). CONCLUSIONS: This hypothesis-generating analysis does not find an interaction between AHRE duration and anticoagulation therapy in patients with device-detected AHRE and stroke risk factors. Further research is needed to identify patients with long AHRE at high stroke risk.


Subject(s)
Atrial Fibrillation , Pyridines , Stroke , Thiazoles , Humans , Female , Aged , Aged, 80 and over , Male , Atrial Fibrillation/complications , Atrial Fibrillation/drug therapy , Atrial Fibrillation/diagnosis , Heart Atria , Risk Factors , Stroke/etiology , Stroke/prevention & control , Stroke/diagnosis , Anticoagulants/therapeutic use
3.
Circulation ; 148(1): 35-46, 2023 07 04.
Article in English | MEDLINE | ID: mdl-37199171

ABSTRACT

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Catheter Ablation , Pulmonary Veins , Humans , Female , Middle Aged , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/drug therapy , Retrospective Studies , Stroke Volume , Ventricular Function, Left , Treatment Outcome , Atrial Flutter/etiology , Registries , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
4.
Circ Res ; 130(7): 994-1010, 2022 04.
Article in English | MEDLINE | ID: mdl-35193397

ABSTRACT

RATIONALE: Atrial fibrillation (AF) and heart failure often coexist, but their interaction is poorly understood. Clinical data indicate that the arrhythmic component of AF may contribute to left ventricular (LV) dysfunction. OBJECTIVE: This study investigates the effects and molecular mechanisms of AF on the human LV. METHODS AND RESULTS: Ventricular myocardium from patients with aortic stenosis and preserved LV function with sinus rhythm or rate-controlled AF was studied. LV myocardium from patients with sinus rhythm and patients with AF showed no differences in fibrosis. In functional studies, systolic Ca2+ transient amplitude of LV cardiomyocytes was reduced in patients with AF, while diastolic Ca2+ levels and Ca2+ transient kinetics were not statistically different. These results were confirmed in LV cardiomyocytes from nonfailing donors with sinus rhythm or AF. Moreover, normofrequent AF was simulated in vitro using arrhythmic or rhythmic pacing (both at 60 bpm). After 24 hours of AF-simulation, human LV cardiomyocytes from nonfailing donors showed an impaired Ca2+ transient amplitude. For a standardized investigation of AF-simulation, human iPSC-cardiomyocytes were tested. Seven days of AF-simulation caused reduced systolic Ca2+ transient amplitude and sarcoplasmic reticulum Ca2+ load likely because of an increased diastolic sarcoplasmic reticulum Ca2+ leak. Moreover, cytosolic Na+ concentration was elevated and action potential duration was prolonged after AF-simulation. We detected an increased late Na+ current as a potential trigger for the detrimentally altered Ca2+/Na+-interplay. Mechanistically, reactive oxygen species were higher in the LV of patients with AF. CaMKII (Ca2+/calmodulin-dependent protein kinase IIδc) was found to be more oxidized at Met281/282 in the LV of patients with AF leading to an increased CaMKII activity and consequent increased RyR2 phosphorylation. CaMKII inhibition and ROS scavenging ameliorated impaired systolic Ca2+ handling after AF-simulation. CONCLUSIONS: AF causes distinct functional and molecular remodeling of the human LV. This translational study provides the first mechanistic characterization and the potential negative impact of AF in the absence of tachycardia on the human ventricle.


Subject(s)
Atrial Fibrillation , Calcium/metabolism , Calcium-Calmodulin-Dependent Protein Kinase Type 2/metabolism , Humans , Myocytes, Cardiac/metabolism , Ryanodine Receptor Calcium Release Channel/metabolism , Sarcoplasmic Reticulum/metabolism
5.
Eur Radiol ; 34(2): 981-993, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37580598

ABSTRACT

OBJECTIVES: To assess the feasibility, precision, and accuracy of left ventricular (LV) and left atrial (LA) volumetric function evaluation from native magnetic resonance (MR) multislice 4D flow magnitude images. MATERIALS & METHODS: In this prospective study, 60 subjects without signs or symptoms of heart failure underwent 3T native cardiac MR multislice 4D flow and bSSFP-cine realtime imaging. LV and LA volumetric function parameters were evaluated from 4D flow magnitude (4D flow-cine) and bSSFP-cine data using standard software to obtain end-diastolic volume (EDV), end-systolic volume (ESV), ejection-fraction (EF), stroke-volume (SV), LV muscle mass (LVM), LA maximum volume, LA minimum volume, and LA total ejection fraction (LATEF). Stroke volumes derived from both imaging methods were further compared to 4D pulmonary artery flow-derived net forward volumes (NFV). Methods were compared by correlation and Bland-Altman analysis. RESULTS: Volumetric function parameters from 4D flow-cine and bSSFP-cine showed high to very high correlations (r = 0.83-0.98). SV, LA volumes and LATEF did not differ between methods. LV end-diastolic and end-systolic volumes were slightly underestimated (EDV: -2.9 ± 5.8 mL; ESV: -2.3 ± 3.8 mL), EF was slightly overestimated (EF: 0.9 ± 2.6%), and LV mass was considerably overestimated (LVM: 39.0 ± 11.4 g) by 4D flow-cine imaging. SVs from both methods correlated very highly with NFV (r = 0.91 in both cases) and did not differ from NFV. CONCLUSION: Native multislice 4D flow magnitude data allows precise evaluation of LV and LA volumetric parameters; however, apart from SV, LV volumetric parameters demonstrate bias and need to be referred to their respective normal values. CLINICAL RELEVANCE STATEMENT: Volumetric function assessment from native multislice 4D flow magnitude images can be performed with routinely used clinical software, facilitating the application of 4D flow as a one-stop-shop functional cardiac MR exam, providing consistent, simultaneously acquired, volume and flow data. KEY POINTS: • Native multislice 4D flow imaging allows evaluation of volumetric left ventricular and atrial function parameters. • Left ventricular and left atrial function parameters derived from native multislice 4D flow data correlate highly with corresponding standard cine-derived parameters. • Multislice 4D flow-derived volumetric stroke volume and net forward volume do not differ.


Subject(s)
Atrial Function, Left , Magnetic Resonance Imaging , Humans , Prospective Studies , Stroke Volume , Heart Ventricles/diagnostic imaging , Ventricular Function, Left/physiology , Magnetic Resonance Imaging, Cine/methods , Reproducibility of Results
6.
Europace ; 26(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38848447

ABSTRACT

Pulsed field ablation (PFA) is an innovative approach in the field of cardiac electrophysiology aimed at treating cardiac arrhythmias. Unlike traditional catheter ablation energies, which use radiofrequency or cryothermal energy to create lesions in the heart, PFA utilizes pulsed electric fields to induce irreversible electroporation, leading to targeted tissue destruction. This state-of-the-art review summarizes biophysical principles and clinical applications of PFA, highlighting its potential advantages over conventional ablation methods. Clinical data of contemporary PFA devices are discussed, which combine predictable procedural outcomes and a reduced risk of thermal collateral damage. Overall, these technological developments have propelled the rapid evolution of contemporary PFA catheters, with future advancements potentially impacting patient care.


Subject(s)
Arrhythmias, Cardiac , Humans , Arrhythmias, Cardiac/surgery , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnosis , Electroporation/trends , Electroporation/methods , Treatment Outcome , Forecasting , Catheter Ablation/trends , Catheter Ablation/methods , Ablation Techniques/trends , Cardiac Catheters , Animals
7.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38696675

ABSTRACT

AIMS: Contact force (CF)-sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. METHODS AND RESULTS: Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. CONCLUSION: A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05752487.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Male , Female , Catheter Ablation/methods , Catheter Ablation/instrumentation , Middle Aged , Treatment Outcome , Aged , Imaging, Three-Dimensional , Cardiac Catheters , Time Factors , Equipment Design , Prospective Studies , Recurrence
8.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38646926

ABSTRACT

AIMS: Using thermal-based energy sources [radiofrequency (RF) energy/cryo energy] for catheter ablation is considered effective and safe when performing pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF). However, treatment success remains limited and complications can occur due to the propagation of thermal energy into non-target tissues. We aim to compare pulsed field ablation (PFA) with RF ablation in terms of efficacy and safety for patients with drug-resistant paroxysmal AF. METHODS AND RESULTS: The BEAT PAROX-AF trial is a European multicentre, superiority, open-label randomized clinical trial in two parallel groups. A total of 292 participants were recruited in 9 high-volume European clinical centres in 5 countries. Patients with paroxysmal AF were randomized to PFA (FARAPULSE Endocardial Ablation System©, Boston Scientific) or RF using the CLOSE protocol with contact force sensing catheter (SmartTouch© catheter and CARTO© Biosense Webster). The primary endpoint will be the 1-year recurrence of atrial arrhythmia, and the major secondary safety endpoint will be the occurrence of acute (<7 days) procedure-related serious adverse events, or pulmonary vein stenosis, or atrio-oesophageal fistula up to 12 months. Additionally, five sub-studies investigate the effect of PFA on oesophageal safety, cerebral lesions, cardiac autonomic nervous system, durability of PVI as assessed during redo ablation procedures, and atrial and ventricular function. The study began on 27 December 2021 and concluded recruitment on 17 January 2024. Results will be available in mid-2025. CONCLUSION: The BEAT PAROX-AF trial aims to provide critical insights into the optimal treatment approach for patients with paroxysmal AF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Catheter Ablation/methods , Treatment Outcome , Pulmonary Veins/surgery , Female , Male , Recurrence , Europe , Middle Aged
9.
Europace ; 26(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38818846

ABSTRACT

AIMS: We aimed to assess the acute and midterm efficacy of premature ventricular contraction (PVC) ablation guided by multielectrode and point-by-point (PbP) mapping. METHODS AND RESULTS: This is a retrospective, international multicentre study of consecutive patients referred for PVC ablation in 10 hospital centres from January 2017 to December 2021. Based on the mapping approach, two cohorts were identified: the 'Multipolar group', where a dedicated high-density mapping catheter was employed, and the 'PbP group', where mapping was performed with the ablation catheter. Procedural endpoints, safety, and acute (procedural) and midterm efficacies were assessed. Of the 698 patients included in this study, 592 received activation mapping [46% males, median age of 55 (41-65) years]-248 patients in the Multipolar group and 344 patients in the PbP group. A higher number of activation points [432 (217-843) vs. 95 (42-185), P < 0.001], reduced mapping time (40 ± 38 vs. 61 ± 50 min, P < 0.001), and shorter procedure time (124 ± 60 vs. 143 ± 63 min, P < 0.001) were reported in the Multipolar group. Both groups had high acute success rates (84.7% with Multipolar mapping vs. 81.3% with PbP mapping, P = 0.63), as well as midterm efficacy (83.4% vs. 77.4%, P = 0.08), with no significant differences in the risk of adverse events (6.0% vs. 3.5%, P = 0.24). However, for left-sided PVC ablation specifically, there was a higher midterm efficacy in the Multipolar group (80.7% vs. 69.5%, P = 0.04), with multipolar mapping being an independent predictor of success [adjusted OR = 2.231 (95% CI, 1.476-5.108), P = 0.02]. CONCLUSION: The acute and midterm efficacies of PVC ablation are high with both multipolar and PbP mapping, although the former allows for quicker procedures and may potentially improve the outcomes of left-sided PVC ablation.


Subject(s)
Catheter Ablation , Ventricular Premature Complexes , Humans , Ventricular Premature Complexes/surgery , Ventricular Premature Complexes/physiopathology , Ventricular Premature Complexes/diagnosis , Male , Middle Aged , Female , Catheter Ablation/methods , Retrospective Studies , Aged , Adult , Treatment Outcome , Electrophysiologic Techniques, Cardiac
10.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38591838

ABSTRACT

AIMS: Recent trial data demonstrate beneficial effects of active rhythm management in patients with atrial fibrillation (AF) and support the concept that a low arrhythmia burden is associated with a low risk of AF-related complications. The aim of this document is to summarize the key outcomes of the 9th AFNET/EHRA Consensus Conference of the Atrial Fibrillation NETwork (AFNET) and the European Heart Rhythm Association (EHRA). METHODS AND RESULTS: Eighty-three international experts met in Münster for 2 days in September 2023. Key findings are as follows: (i) Active rhythm management should be part of the default initial treatment for all suitable patients with AF. (ii) Patients with device-detected AF have a low burden of AF and a low risk of stroke. Anticoagulation prevents some strokes and also increases major but non-lethal bleeding. (iii) More research is needed to improve stroke risk prediction in patients with AF, especially in those with a low AF burden. Biomolecules, genetics, and imaging can support this. (iv) The presence of AF should trigger systematic workup and comprehensive treatment of concomitant cardiovascular conditions. (v) Machine learning algorithms have been used to improve detection or likely development of AF. Cooperation between clinicians and data scientists is needed to leverage the potential of data science applications for patients with AF. CONCLUSIONS: Patients with AF and a low arrhythmia burden have a lower risk of stroke and other cardiovascular events than those with a high arrhythmia burden. Combining active rhythm control, anticoagulation, rate control, and therapy of concomitant cardiovascular conditions can improve the lives of patients with AF.


Subject(s)
Atrial Fibrillation , Stroke , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Stroke/etiology , Stroke/prevention & control , Risk , Hemorrhage , Anticoagulants/therapeutic use
11.
Pacing Clin Electrophysiol ; 47(1): 117-120, 2024 01.
Article in English | MEDLINE | ID: mdl-37885274

ABSTRACT

Pulse field ablation (PFA) is a novel nonthermal ablation modality for treatment of atrial fibrillation. While mostly lacking 3D electroanatomical mapping integration, reported radiation doses in procedures using multielectrode PFA catheters are relatively high. We report a first case series of three patients where a zero-fluoroscopy approach by intracardiac echocardiography was utilized and present a possible workflow for zero-fluoroscopy ablation with the Farapulse PFA system.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Irreversible Electroporation Therapy , Treatment Outcome , Catheter Ablation/methods , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Fluoroscopy/methods
12.
Cardiol Young ; : 1-2, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38712631

ABSTRACT

Ebstein anomaly is frequently associated with accessory pathways, including Mahaim atriofascicular fibres. We herein illustrate successful Mahaim fibre ablation in Ebstein anomaly by targeting the ventricular insertion site below the tricuspid ridge.

13.
Circulation ; 145(25): 1853-1866, 2022 06 21.
Article in English | MEDLINE | ID: mdl-35616058

ABSTRACT

BACKGROUND: The insulin-like growth factor 1 (IGF1) pathway is a key regulator of cellular metabolism and aging. Although its inhibition promotes longevity across species, the effect of attenuated IGF1 signaling on cardiac aging remains controversial. METHODS: We performed a lifelong study to assess cardiac health and lifespan in 2 cardiomyocyte-specific transgenic mouse models with enhanced versus reduced IGF1 receptor (IGF1R) signaling. Male mice with human IGF1R overexpression or dominant negative phosphoinositide 3-kinase mutation were examined at different life stages by echocardiography, invasive hemodynamics, and treadmill coupled to indirect calorimetry. In vitro assays included cardiac histology, mitochondrial respiration, ATP synthesis, autophagic flux, and targeted metabolome profiling, and immunoblots of key IGF1R downstream targets in mouse and human explanted failing and nonfailing hearts, as well. RESULTS: Young mice with increased IGF1R signaling exhibited superior cardiac function that progressively declined with aging in an accelerated fashion compared with wild-type animals, resulting in heart failure and a reduced lifespan. In contrast, mice with low cardiac IGF1R signaling exhibited inferior cardiac function early in life, but superior cardiac performance during aging, and increased maximum lifespan, as well. Mechanistically, the late-life detrimental effects of IGF1R activation correlated with suppressed autophagic flux and impaired oxidative phosphorylation in the heart. Low IGF1R activity consistently improved myocardial bioenergetics and function of the aging heart in an autophagy-dependent manner. In humans, failing hearts, but not those with compensated hypertrophy, displayed exaggerated IGF1R expression and signaling activity. CONCLUSIONS: Our findings indicate that the relationship between IGF1R signaling and cardiac health is not linear, but rather biphasic. Hence, pharmacological inhibitors of the IGF1 pathway, albeit unsuitable for young individuals, might be worth considering in older adults.


Subject(s)
Insulin-Like Growth Factor I , Longevity , Aged , Animals , Health Promotion , Humans , Insulin-Like Growth Factor I/metabolism , Male , Mice , Myocytes, Cardiac/metabolism , Phosphatidylinositol 3-Kinases/metabolism , Receptor, IGF Type 1/genetics , Receptor, IGF Type 1/metabolism
14.
Eur Radiol ; 2023 Nov 13.
Article in English | MEDLINE | ID: mdl-37953367

ABSTRACT

OBJECTIVES: The magnetic resonance (MR) 4D flow imaging-derived left atrial (LA) acceleration factor α was recently introduced as a means to non-invasively estimate LA pressure. We aimed to investigate the association of α with the severity of left ventricular (LV) diastolic dysfunction using echocardiography as the reference method. METHODS: Echocardiographic assessment of LV diastolic function and 3-T cardiac MR 4D flow imaging were prospectively performed in 94 subjects (44 male/50 female; mean age, 62 ± 12 years). LA early diastolic peak outflow velocity (vE), systolic peak inflow velocity (vS), and early diastolic peak inflow velocity (vD) were evaluated from 4D flow data. α was calculated from α = vE / [(vS + vD) / 2]. Mean parameter values were compared by t-test; diagnostic performance of α in predicting diastolic (dys)function was investigated by receiver operating characteristic curve analysis. RESULTS: Mean α values were 1.17 ± 0.14, 1.20 ± 0.08, 1.33 ± 0.15, 1.77 ± 0.18, and 2.79 ± 0.69 for grade 0 (n = 51), indeterminate (n = 9), grade I (n = 13), grade II (n = 13), and grade III (n = 8) LV diastolic (dys)function, respectively. α differed between subjects with non-advanced (grade < II) and advanced (grade ≥ II) diastolic dysfunction (1.20 ± 0.15 vs. 2.16 ± 0.66, p < 0.001). The area under the curve (AUC) for detection of advanced diastolic dysfunction was 0.998 (95% CI: 0.958-1.000), yielding sensitivity of 100% (95% CI: 84-100%) and specificity of 99% (95% CI: 93-100%) at cut-off α ≥ 1.58. The AUC for differentiating grade III diastolic dysfunction was also 0.998 (95% CI: 0.976-1.000) at cut-off α ≥ 2.14. CONCLUSION: The 4D flow-derived LA acceleration factor α allows grade II and grade III diastolic dysfunction to be distinguished from non-advanced grades as well as from each other. CLINICAL RELEVANCE STATEMENT: As a single continuous parameter, the 4D flow-derived LA acceleration factor α shows potential to simplify the multi-parametric imaging algorithm for diagnosis of advanced LV diastolic dysfunction, thereby identifying patients at increased risk for cardiovascular events. KEY POINTS: • Detection of advanced diastolic dysfunction is typically performed using a complex, multi-parametric approach. • The 4D flow-derived left atrial acceleration factor α alone allows accurate detection of advanced left ventricular diastolic dysfunction. • As a single continuous parameter, the left atrial acceleration factor α could simplify the diagnosis of advanced diastolic dysfunction.

15.
Europace ; 25(2): 667-675, 2023 02 16.
Article in English | MEDLINE | ID: mdl-36512365

ABSTRACT

Catheter ablation (CA) of atrial fibrillation (AF) is the therapy of choice for the maintenance of sinus rhythm in patients with symptomatic AF. Time towards interventional treatment and peri-procedural management of patients undergoing AF ablation may vary in daily practice. The scope of this European Heart Rhythm Association (EHRA) survey was to report the current clinical practice regarding the management of patients undergoing AF ablation and physician's adherence to the European Society of Cardiology Guidelines and the EHRA/HRS/ECAS expert consensus statement on the CA for AF. This physician-based survey was conducted among EHRA members, using an internet-based questionnaire developed by the EHRA Scientific Initiatives Committee. A total of 258 physicians participated in the survey. In patients with paroxysmal or persistent AF, 42 and 9% of the physicians would routinely perform AF ablation as first-line therapy respectively, whereas 71% of physicians would consider ablation as first-line therapy in patients with symptomatic AF and left ventricular ejection fraction <35%. Only 14% of the respondents manage cardiovascular risk factors in patients referred for CA using a dedicated AF risk factor management programme. Radiofrequency CA is the preferred technology for first-time AF (56%), followed by cryo-balloon CA (40%). This EHRA survey demonstrated a considerable variation in the management of patients undergoing AF ablation in routine practice and deviations between guideline recommendations and clinical practice.


Subject(s)
Ablation Techniques , Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/drug therapy , Patient Selection , Stroke Volume , Ventricular Function, Left , Surveys and Questionnaires , Catheter Ablation/methods , Treatment Outcome
16.
Europace ; 25(12)2023 12 06.
Article in English | MEDLINE | ID: mdl-37897713

ABSTRACT

AIMS: Left atrial catheter ablation is well established in patients with symptomatic atrial fibrillation (AF) but associated with risk of embolism to the brain. The present analysis aims to assess the impact of diffusion-weighted imaging (DWI) slice thickness on the rate of magnetic resonance imaging (MRI)-detected ischaemic brain lesions after ablation. METHODS AND RESULTS: AXAFA-AFNET 5 trial (NCT02227550) participants underwent MRI using high-resolution (hr) DWI (slice thickness: 2.5-3 mm) and standard DWI (slice thickness: 5-6 mm) within 3-48 h after ablation. In 321 patients with analysable brain MRI (mean age 64 years, 33% female, median CHA2DS2-VASc 2), hrDWI detected at least one acute brain lesion in 84 (26.2%) patients and standard DWI in 60 (18.7%; P < 0.01) patients. High-resolution diffusion-weighted imaging detected more lesions compared to standard DWI (165 vs. 104; P < 0.01). The degree of agreement for lesion confirmation using hrDWI vs. standard DWI was substantial (κ = 0769). Comparing the proportion of DWI-detected lesions, lesion distribution, and total lesion volume per patient, there was no difference in the cohort of participants undergoing MRI at 1.5 T (n = 52) vs. 3 T (n = 269). CONCLUSION: The pre-specified AXAFA-AFNET 5 sub-analysis revealed significantly increased rates of MRI-detected acute brain lesions using hrDWI instead of standard DWI in AF patients undergoing ablation. In comparison to DWI slice thickness, MRI field strength had a no significant impact in the trial. Comparing the varying rates of ablation-related MRI-detected brain lesions across previous studies has to consider these technical parameters. Future studies should use hrDWI, as feasibility was demonstrated in the multicentre AXAFA-AFNET 5 trial.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Female , Middle Aged , Male , Magnetic Resonance Imaging/methods , Diffusion Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects
17.
Europace ; 25(2): 374-381, 2023 02 16.
Article in English | MEDLINE | ID: mdl-36414239

ABSTRACT

AIMS: Cryoballoon (CB)-based pulmonary vein isolation (PVI) is an effective treatment for atrial fibrillation (AF). The most frequent complication during CB-based PVI is right-sided phrenic nerve injury (PNI) which is leading to premature abortion of the freeze cycle. Here, we analysed reconnection rates after CB-based PVI and PNI in a large-scale population during repeat procedures. METHODS AND RESULTS: In the YETI registry, a total of 17 356 patients underwent CB-based PVI in 33 centres, and 731 (4.2%) patients experienced PNI. A total of 111/731 (15.2%) patients received a repeat procedure for treatment of recurrent AF. In 94/111 (84.7%) patients data on repeat procedures were available. A total of 89/94 (94.7%) index pulmonary veins (PVs) have been isolated during the initial PVI. During repeat procedures, 22 (24.7%) of initially isolated index PVs showed reconnection. The use of a double stop technique did non influence the PV reconnection rate (P = 0.464). The time to PNI was 140.5 ± 45.1 s in patients with persistent PVI and 133.5 ± 53.8 s in patients with reconnection (P = 0.559). No differences were noted between the two populations in terms of CB temperature at the time of PNI (P = 0.362). The only parameter associated with isolation durability was CB temperature after 30 s of freezing. The PV reconnection did not influence the time to AF recurrence. CONCLUSION: In patients with cryoballon application abortion due to PNI, a high rate of persistent PVI rate was found at repeat procedures. Our data may help to identify the optimal dosing protocol in CB-based PVI procedures. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT03645577?term=YETI&cntry=DE&draw=2&rank=1 ClinicalTrials.gov Identifier: NCT03645577.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Catheter Ablation/adverse effects , Cryosurgery/adverse effects , Cryosurgery/methods , Phrenic Nerve , Pulmonary Veins/surgery , Recurrence , Time Factors , Treatment Outcome
18.
Am Heart J ; 246: 152-160, 2022 04.
Article in English | MEDLINE | ID: mdl-35045327

ABSTRACT

Sodium glucose cotransporter 2 (SGLT2) have proven profound positive effects in heart failure with reduced ejection fraction (HFrEF). These effects are independent from the presence of diabetes. Metabolic effects, antiinflammatory, and antifibrotic properties are discussed as underlying mechanisms. Despite a strong correlation of ventricular arrhythmias with HFrEF, the impact of ertugliflozin on the ventricular arrhythmic burden has not been investigated, yet. Therefore, the Ertugliflozin to Reduce Arrhythmic burden in ICD ± CRT patientS (ERASe) trial was designed to investigate the efficacy and safety of ertugliflozin in patients with reduced and midrange ejection fraction (EF) with or without diabetes. METHODS: Within a multicentre, national, randomized, double-blind, placebo-controlled, phase 3b trial we aim to enrol a total of 402 patients across Austria. Patients with reduced or midrange EF and ICD ± CRT therapy >3 months and previous ventricular tachycardia (at least 10 documented VT episodes within the last 12 months) are randomized in a 1:1 ratio to ertugliflozin (5 mg once daily orally administered) or matching placebo. The primary endpoint of the ERASe trial is to investigate the impact of ertugliflozin on total burden of ventricular arrhythmias. Further objectives will include number of therapeutic interventions of implanted devices, atrial fibrillation and heart failure biomarkers. CONCLUSION: The ERASe trial will be the first trial to test ertugliflozin in heart failure patients with nonpreserved ejection fraction and ongoing ICD ± CRT therapy regardless of their diabetic status. The ERASe trial may therefore extend the concept of SGLT2 inhibition to improve cardiac remodelling, including reduced arrhythmic burden. Trial registration Identifier EudraCT Nr. 2020-002581-14 / ClinicalTrials.gov Identifier: NCT04600921.


Subject(s)
Defibrillators, Implantable , Heart Failure , Bridged Bicyclo Compounds, Heterocyclic/therapeutic use , Double-Blind Method , Heart Failure/drug therapy , Heart Failure/therapy , Humans , Stroke Volume/physiology , Treatment Outcome , Ventricular Function, Left/physiology
19.
Catheter Cardiovasc Interv ; 100(3): 319-327, 2022 09.
Article in English | MEDLINE | ID: mdl-35830719

ABSTRACT

AIM: Cardiogenic shock (CS) is a hemodynamically complex multisystem syndrome associated with persistently high morbidity and mortality. As CS is characterized by progressive failure to provide adequate systemic perfusion, supporting end-organ perfusion using mechanical circulatory support (MCS) seems intriguing. Since most patients with CS present in the catheterization laboratory, percutaneously implantable systems have the widest adoption in the field. We evaluated feasibility, outcomes, and complications after the introduction of a full-percutaneous program for both the Impella CP device and venoarterial extracorporeal membrane oxygenator (VA-ECMO). METHODS: PREPARE CardShock (PRospective REgistry of PAtients in REfractory cardiogenic shock) is a prospective single-center registry, including 248 consecutive patients between May 2019 and April 2021, who underwent cardiac catheterization and displayed advanced cardiogenic shock. The median age was 70 (58-77) years and 28% were female. Sixty-five percent of the cases had cardiac arrest, of which 66% were out-of-hospital cardiac arrest. A local standard operating procedure (SOP) indicating indications as well as relative and absolute contraindications for different means of MCS (Impella CP or VA-ECMO) was used to guide MCS use. The primary endpoint was in-hospital death and secondary endpoints were spontaneous myocardial infarction and major bleedings during the hospital stay. RESULTS: Overall mortality was 50.4% with a median survival of 2 (0-6) days. Significant independent predictors of mortality were cardiac arrest during the index event (odds ratio [OR] with 95% confidence interval [CI]: 2.53 [1.43-4.51]; p = 0.001), age > 65 years (OR: 2.05 [1.03-4.09]; p = 0.036]), pH < 7.30 (OR: 2.69 [1.56-4.66]; p < 0.001), and lactate levels > 2 mmol/L (OR: 4.51 [2.37-8.65]; p < 0.001). CONCLUSIONS: Conclusive SOPs assist target-orientated MCS use in CS. This study provides guidance on the implementation, validation, and modification of newly established MCS programs to aid centers that are establishing such programs.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart Arrest , Heart-Assist Devices , Aged , Female , Heart-Assist Devices/adverse effects , Hospital Mortality , Humans , Male , Registries , Retrospective Studies , Shock, Cardiogenic/diagnosis , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy , Treatment Outcome
20.
Eur J Neurol ; 29(1): 149-157, 2022 01.
Article in English | MEDLINE | ID: mdl-34519135

ABSTRACT

BACKGROUND AND PURPOSE: Atrial fibrillation (AF) often remains undiagnosed in cryptogenic stroke (CS), mostly because of limited availability of cardiac long-term rhythm monitoring. There is an unmet need for a pre-selection of CS patients benefitting from such work-up. A clinical risk score was therefore developed for the prediction of AF after CS and its performance was evaluated over 1 year of follow-up. METHODS: Our proposed risk score ranges from 0 to 16 points and comprises variables known to be associated with occult AF in CS patients including age, N-terminal pro-brain natriuretic peptide, electrocardiographic and echocardiographic features (supraventricular premature beats, atrial runs, atrial enlargement, left ventricular ejection fraction) and brain imaging markers (multi-territory/prior cortical infarction). All CS patients admitted to our Stroke Unit between March 2018 and August 2019 were prospectively followed for AF detection over 1 year after discharge. RESULTS: During the 1-year follow-up, 24 (16%) out of 150 CS patients with AF (detected via electrocardiogram controls, n = 18; loop recorder monitoring, n = 6) were diagnosed. Our predefined AF Risk Score (cutoff ≥4 points; highest Youden's index) had a sensitivity of 92% and a specificity of 67% for 1-year prediction of AF. Notably, only two CS patients with <4 score points were diagnosed with AF later on (negative predictive value 98%). CONCLUSIONS: A clinical risk score for 1-year prediction of AF in CS with high sensitivity, reasonable specificity and excellent negative predictive value is presented. Generalizability of our score needs to be tested in external cohorts with continuous cardiac rhythm monitoring.


Subject(s)
Atrial Fibrillation , Ischemic Stroke , Stroke , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Humans , Risk Factors , Stroke/complications , Stroke/diagnostic imaging , Stroke Volume , Ventricular Function, Left