Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Thorac Cardiovasc Surg ; 67(7): 516-523, 2019 Oct.
Article in English | MEDLINE | ID: mdl-30114713

ABSTRACT

BACKGROUND: The aim of this study was to quantify acute mitral valve (MV) geometry dynamic changes throughout the cardiac cycle using three-dimensional transesophageal echocardiography (3D TEE) in patients undergoing surgical MV repair (MVR) with ring annuloplasty and optional neochord implantation. METHODS: Twenty-nine patients (63 ± 10 years) with severe primary mitral regurgitation underwent surgical MVR using ring annuloplasty with or without neochord implantation. We recorded 3D TEE data throughout the cardiac cycle before and after MVR. Dynamic changes (4D) in the MV annulus geometry and anatomical MV orifice area (AMVOA) were measured using a novel semiautomated software (Auto Valve, Siemens Healthcare). RESULTS: MVR significantly reduces the anteroposterior diameter by up to 38% at end-systole (36.8-22.7 mm; p < 0.001) and the lateromedial diameter by up to 31% (42.7-30.3 mm; p < 0.001). Moreover, the annular circumference was reduced by up to 31% at end-systole (129.6-87.6 mm, p < 0.001), and the annular area was significantly decreased by up to 52% (12.8-5.7 cm2; p < 0.001). Finally, the AMVOA experienced the largest change, decreasing from 1.1 to 0.2 cm2 during systole (at midsystole; p < 0.001) and from 4.1 to 3.2 cm2 (p < 0.001) during diastole. CONCLUSIONS: MVR reduces the annular dimension and the AMVOA, contributing to mitral competency, but the use of annuloplasty rings reduces annular contractility after the procedure. Surgeons can use 4D imaging technology to assess MV function dynamically, detecting the acute morphological changes of the mitral annulus and leaflets before and after the procedure.


Subject(s)
Heart Valve Prosthesis Implantation , Hemodynamics , Mitral Valve Annuloplasty , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Aged , Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve Annuloplasty/adverse effects , Mitral Valve Annuloplasty/instrumentation , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Prosthesis Design , Recovery of Function , Severity of Illness Index , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL