Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 59
Filter
Add more filters

Publication year range
1.
Int J Mol Sci ; 24(18)2023 Sep 06.
Article in English | MEDLINE | ID: mdl-37762074

ABSTRACT

The number of elderly dogs is increasing significantly worldwide, and many elderly dogs develop canine cognitive dysfunction syndrome (CCDS). CCDS is the canine analog of Alzheimer's disease (AD) in humans. It is very important to develop techniques for detecting CDDS in dogs. Thus, we used the detection of neurofilament light chains (NfL) in plasma as a blood-based biomarker for the early diagnosis of canine Alzheimer's disease using immunomagnetic reduction (IMR) technology by immobilizing NfL antibodies on magnetic nanoparticles. According to the 50-point CCDS rating scale, we divided 36 dogs into 15 with CCDS and 21 without the disease. The results of our IMR assay showed that the plasma NfL levels of dogs with CCDS were significantly increased compared to normal dogs (p < 0.01). By plasma biochemical analysis, we further confirmed that the liver and renal dysfunction biomarkers of dogs with CCDS were significantly elevated compared to normal dogs (p < 0.01-0.05). On the basis of our preliminary study, we propose that IMR technology could be an ideal biosensor for detecting plasma NfL for the early diagnosis of CCDS.

2.
Dement Geriatr Cogn Disord ; 49(4): 401-409, 2020.
Article in English | MEDLINE | ID: mdl-33242863

ABSTRACT

BACKGROUND: A previously published paper (referred to as the original cohort) showed that using a cutoff value of 116.1 fg/mL for the plasma total α-synuclein concentrations could discriminate Parkinson's disease (PD) patients from normal controls (NCs). In this study, another independent cohort (referred to as the validation cohort) was recruited to validate the agreement between the clinical diagnosis and the use of plasma total α-synuclein to identify PD patients. In addition to total α-synuclein, plasma neurofilament light chain (NfL) in the validation cohort was detected. METHODS: Seventy PD patients and 33 NCs were enrolled in the validation cohort. A clinical diagnosis and the immunomagnetic reduction (IMR) assay for plasma total α-synuclein were performed for each participant. Thirty-three of 70 PD patients and 23 of 33 NCs were subjected to the plasma NfL assay via IMR. RESULTS: The positive, negative, and overall percentages of agreement between the clinical diagnosis and plasma total α-synuclein diagnosis determined based on 116.1 fg/mL as the cutoff value were found to be 0.943, 0.818, and 0.903, respectively. The PD patients and NCs showed plasma NfL levels of 8.38 ± 4.19 pg/mL and 17.6 ± 7.95 pg/mL (p < 0.001), respectively. The cutoff value of the plasma NfL level used to differentiate PD patients from NCs was 12.8 pg/mL, with sensitivity and specificity values of 0.788 and 0.870, respectively. CONCLUSION: The results demonstrate the usefulness of the plasma total α-synuclein concentration to discriminate PD patients from NCs and reveal the elevation of the plasma NfL level in PD patients.


Subject(s)
Intermediate Filaments/metabolism , Parkinson Disease , alpha-Synuclein/blood , Biomarkers/blood , Cohort Studies , Diagnosis, Differential , Female , Humans , Male , Middle Aged , Parkinson Disease/blood , Parkinson Disease/diagnosis
3.
Dement Geriatr Cogn Disord ; 49(3): 303-311, 2020.
Article in English | MEDLINE | ID: mdl-32784295

ABSTRACT

BACKGROUND: The stability of proteins in the collecting tubes after blood draw is critical to the measured concentrations of the proteins. Although the guidelines issued by the Clinical and Laboratory Standards Institute (CLSI) suggest centrifugation should take place within 2 h of drawing blood, it is very difficult to follow these guidelines in hospitals or clinics. It is necessary to study the effect of times to blood processing on the stability of the proteins of interest. METHODS: In this work, the plasma proteins of interest were those relevant to dementia, such as amyloid ß 1-40 (Aß1-40), Aß1-42, Tau protein (Tau), and α-synuclein. The times to blood processing after blood draw ranged from 0.5 to 8 h. The storage temperatures of blood were room temperature (approx. 25°C) and 30°C. After storage, blood samples were centrifuged at room temperature to obtain plasma samples. Ultrasensitive immunomagnetic reduction was applied to assay these proteins in the plasma. RESULTS: The levels of plasma Aß1-40, Tau, and α-synuclein did not significantly change until 8 h after blood draw when stored at room temperature. Plasma Aß1-42 levels did not change significantly after 8 h of storage at room temperature before blood processing. Higher storage temperatures, such as 30°C, for blood samples accelerated the significant variations in the measured concentrations of Aß1-40, Tau, and α-synuclein in plasma. CONCLUSION: According to these results, for clinical practice, it is suggested that blood samples be stored at room temperature for no longer than 4.5 h after blood draw until centrifugation for the assay of dementia biomarkers in plasma.


Subject(s)
Amyloid beta-Peptides/blood , Blood Specimen Collection , Centrifugation , Dementia , alpha-Synuclein/blood , tau Proteins/blood , Biomarkers/blood , Blood Specimen Collection/methods , Blood Specimen Collection/standards , Centrifugation/methods , Centrifugation/standards , Clinical Laboratory Techniques/methods , Clinical Laboratory Techniques/standards , Dementia/blood , Dementia/diagnosis , Dimensional Measurement Accuracy , Humans , Temperature , Time Factors
4.
Nanomedicine ; 28: 102182, 2020 08.
Article in English | MEDLINE | ID: mdl-32222476

ABSTRACT

Blood-based biomarker assays of plasma ß-amyloid (Aß) and tau have the advantages of cost-effective and less invasive for the diagnosis of Alzheimer's disease (AD). We used two independent cohorts to cross-validate the clinical use of the nanoparticle-based immunomagnetic assay of plasma biomarkers to assist in the differential diagnosis of early AD. There were in total 160 subjects in the derivation cohort, and 242 in the validation cohort both containing controls, mild cognitive impairment due to AD and AD dementia diagnosed according to the 2011 NIA-AA guidelines. The cutoff value for plasma Aß1-42 (16.4 pg/ml) performed the best in differentiating between controls and patients with prodromal or clinical AD, with 92.5% for positive percent agreement (PPA), negative percent agreement (NPA), and overall rate of agreement (ORA). Aß1-42 × tau (642.58) was useful for separating patients with dementia and prodromal states of AD, with 84.9% PPA, 78.8% NPA and 83% ORA.


Subject(s)
Alzheimer Disease/blood , Alzheimer Disease/diagnosis , Biomarkers/blood , Dementia/blood , Dementia/diagnosis , Immunoassay/methods , Nanoparticles/chemistry , Aged , Aged, 80 and over , Amyloid beta-Peptides/blood , Cognitive Dysfunction/blood , Cognitive Dysfunction/diagnosis , Cross-Sectional Studies , Diagnosis, Differential , Female , Humans , Male , Middle Aged , tau Proteins/blood
5.
Sensors (Basel) ; 18(4)2018 Mar 30.
Article in English | MEDLINE | ID: mdl-29601532

ABSTRACT

An alternating-current magnetosusceptometer of antibody-functionalized magnetic nanoparticles (MNPs) was developed for immunomagnetic reduction (IMR). A high-sensitivity, high-critical-temperature superconducting quantum interference device was used in the magnetosusceptometer. Minute levels of biomarkers of early-stage neurodegeneration diseases were detectable in serum, but measuring each biomarker required approximately 4 h. Hence, an eight-channel platform was developed in this study to fit minimal screening requirements for Alzheimer's disease. Two consistent results were measured for three biomarkers, namely Aß40, Aß42, and tau protein, per human specimen. This paper presents the instrument configuration as well as critical characteristics, such as the low noise level variations among channels, a high signal-to-noise ratio, and the coefficient of variation for the biomarkers' IMR values. The instrument's ultrahigh sensitivity levels for the three biomarkers and the substantially shorter total measurement time in comparison with the previous single- and four-channels platforms were also demonstrated in this study. Thus, the eight-channel instrument may serve as a powerful tool for clinical high-throughput screening of Alzheimer's disease.


Subject(s)
Magnetite Nanoparticles , Alzheimer Disease , Amyloid beta-Peptides , Biomarkers , Humans , Immunoassay , Magnetics , tau Proteins
6.
J Neurol Neurosurg Psychiatry ; 88(10): 818-824, 2017 10.
Article in English | MEDLINE | ID: mdl-28550072

ABSTRACT

OBJECTIVE: α-Synuclein is critical to the pathogenesis of Parkinson's disease (PD). Few studies examined the plasma levels of α-synuclein due to the exceptionally low level of α-synuclein in plasma compared with cerebrospinal fluid. We aimed to investigate plasma α-synuclein in patients with PD of different disease severity. METHODS: There were total 114 participants, including 80 patients with PD and 34 controls, in the study. Participants received a complete evaluation of motor and non-motor symptoms, including cognitive function. We applied immunomagnetic reduction-based immunoassay to measure plasma levels of α-synuclein. RESULTS: Plasma levels of α-synuclein were significantly higher in patients with PD compared with controls (median: 1.56 pg/mL, 95% CI 1.02 to 1.98 pg/mL vs 0.02 pg/mL, 95% CI 0.01 to 0.03 pg/mL; p<0.0001). Although there was a significant increase in plasma α-synuclein levels in PD patients with a higher Hoehn-Yahr (H-Y) stage, there was no correlation with motor symptom severity, as assessed by Unified Parkinson's Disease Rating Scale part III scores, after confounders (age, gender, and disease duration) were taken into account. However, plasma α-synuclein levels were significantly higher in PD patients with dementia (PDD) than in PD patients with mild cognitive impairment (PD-MCI) or normal cognition (0.42 pg/mL, (95% CI 0.25 to 0.93) for PD with normal cognition; 1.29 pg/mL (95% CI 0.76 to 1.93) for PD-MCI and 4.09 pg/mL (95% CI 1.99 to 6.19) for PDD, p<0.01) and were negatively correlated with Mini-Mental State Examination scores (R2-adjusted=0.3004, p<0.001), even after confounder adjustment. CONCLUSIONS: Our data suggest that plasma α-synuclein level correlates with cognitive decline but not motor severity in patients with PD. Plasma α-synuclein could serve as a surrogate biomarker for patients at risk of cognitive decline.


Subject(s)
Cognitive Dysfunction/blood , Parkinson Disease/complications , alpha-Synuclein/blood , Biomarkers/blood , Cognitive Dysfunction/etiology , Dementia/blood , Dementia/etiology , Humans
7.
J Nanobiotechnology ; 14(1): 41, 2016 Jun 08.
Article in English | MEDLINE | ID: mdl-27278241

ABSTRACT

BACKGROUND: It is difficult to discriminate healthy subjects and patients with Parkinson disease (PD) or Parkinson disease dementia (PDD) by assaying plasma α-synuclein because the concentrations of circulating α-synuclein in the blood are almost the same as the low-detection limit using current immunoassays, such as enzyme-linked immunosorbent assay. In this work, an ultra-sensitive immunoassay utilizing immunomagnetic reduction (IMR) is developed. The reagent for IMR consists of magnetic nanoparticles functionalized with antibodies against α-synuclein and dispersed in pH-7.2 phosphate-buffered saline. A high-Tc superconducting-quantum-interference-device (SQUID) alternative-current magnetosusceptometer is used to measure the IMR signal of the reagent due to the association between magnetic nanoparticles and α-synuclein molecules. RESULTS: According to the experimental α-synuclein concentration dependent IMR signal, the low-detection limit is 0.3 fg/ml and the dynamic range is 310 pg/ml. The preliminary results show the plasma α-synuclein for PD patients distributes from 6 to 30 fg/ml. For PDD patients, the concentration of plasma α-synuclein varies from 0.1 to 100 pg/ml. Whereas the concentration of plasma α-synuclein for healthy subjects is significantly lower than that of PD patients. CONCLUSIONS: The ultra-sensitive IMR by utilizing antibody-functionalized magnetic nanoparticles and high-Tc SQUID magnetometer is promising as a method to assay plasma α-synuclein, which is a potential biomarker for discriminating patients with PD or PDD.


Subject(s)
Antibodies, Immobilized/chemistry , Dementia/blood , Magnetite Nanoparticles/chemistry , Parkinson Disease/blood , alpha-Synuclein/blood , Adult , Aged , Biomarkers/blood , Dementia/diagnosis , Female , Humans , Immunoassay/methods , Limit of Detection , Magnetics/methods , Male , Middle Aged , Parkinson Disease/diagnosis
8.
Hum Brain Mapp ; 35(7): 3132-42, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24129926

ABSTRACT

Neurofibrillary tangles are associated with cognitive dysfunction, and hippocampal atrophy with increased CSF tau markers. However, the plasma tau levels of Alzheimer's disease (AD) have not been well studied. We investigated plasma tau by using an immunomagnetic reduction assay in 20 patients with mild cognitive impairment (MCI) due to AD, 10 early AD dementia, and 30 healthy elders (HE). All received a 3D-brain MRI scan and a set of cognitive function test. We explored their relationships with both brain structure and cognitive functions. Images were analyzed to determine the brain volumes and gray matter densities. Patients with MCI or early AD had significantly increased plasma tau levels compared with HE. Plasma tau levels were negatively associated with the performance of logical memory, visual reproduction, and verbal fluency; also negatively associated with volume of total gray matter, hippocampus, amygdala; and gray matter densities of various regions. Regression analyses indicated that logical memory explained 0.394 and hippocampus volume predicted .608 of the variance of plasma tau levels, both P < 0.001. Education years were negatively associated with the gray matter densities of the supramarginal (r = -0.407), middle temporal gyrus (r = -0.40) and precuneus (r = -0.377; all P < 0.05) in HE; and negatively associated with plasma tau levels in patients (r = -0.626). We propose that plasma tau may serve as a window to both structure and function of the brain. Higher education is a protective factor against AD and is associated with lower plasma tau levels in patients.


Subject(s)
Alzheimer Disease , Brain/pathology , Cognitive Dysfunction , Memory Disorders/etiology , tau Proteins/blood , Aged , Aged, 80 and over , Alzheimer Disease/blood , Alzheimer Disease/complications , Alzheimer Disease/pathology , Apolipoproteins E/genetics , Cognitive Dysfunction/blood , Cognitive Dysfunction/complications , Cognitive Dysfunction/pathology , Female , Humans , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Male , Middle Aged , Nanoparticles , Neuropsychological Tests , Regression Analysis
9.
J Nanobiotechnology ; 12: 44, 2014 Nov 26.
Article in English | MEDLINE | ID: mdl-25424410

ABSTRACT

BACKGROUND: Magnetic nanoparticles functionalized antibodies are used for in-vitro assays on bio-markers. This work demonstrates the synthesis of high-quality magnetic nanoparticles coated with antibodies against carcinoembryonic antigen (CEA). Various characterizations, such as particle size, particle suspension, bio-activity and the stability of bio-magnetic nanoparticles suspended in liquid, are studied. The properties for the assay of CEA molecules in serum are also studied. The assay method used is so-called immunomagnetic reduction. RESULTS: The results show that the effects of common materials in serum that interfere with detected signals are not significant. The low-detection limit is 0.21 ng/ml, which is well below the clinical threshold of 2.5 ng/ml. CONCLUSIONS: The dynamic range for the assay of CEA molecules in serum is 500 ng/ml. By assaying serum CEA molecules from 24 normal controls and 30 colorectal-cancer patients, the threshold for the serum-CEA concentration to diagnose colorectal cancer is 4.05 ng/ml, which results in a clinical sensitivity of 0.90 and specificity of 0.87.


Subject(s)
Antibodies/chemistry , Biomarkers, Tumor/blood , Carcinoembryonic Antigen/blood , Colorectal Neoplasms/blood , Immunoassay/methods , Magnetite Nanoparticles , Antibodies/immunology , Biomarkers, Tumor/immunology , Case-Control Studies , Humans , Limit of Detection , Magnetite Nanoparticles/chemistry , Particle Size , Temperature
10.
medRxiv ; 2024 Aug 22.
Article in English | MEDLINE | ID: mdl-39228740

ABSTRACT

BACKGROUND: Phosphorylated tau (p-tau) is a specific blood biomarker for Alzheimer's disease (AD) pathology. Multiple p-tau biomarkers on several analytical platforms are poised for clinical use. The Alzheimer's Association Global Biomarker Standardisation Consortium plasma phospho-tau Round Robin study engaged assay developers in a blinded case-control study on plasma p-tau, aiming to learn which assays provide the largest fold-changes in AD compared to non-AD, have the strongest relationship between plasma and cerebrospinal fluid (CSF), and show the most consistent relationships between methods (commutability) in measuring both patient samples and candidate reference materials (CRM). METHODS: Thirty-three different p-tau biomarker assays, built on eight different analytical platforms, were used to quantify paired plasma and CSF samples from 40 participants. AD biomarker status was categorised as "AD pathology" (n=25) and "non-AD pathology" (n=15) by CSF Aß42/Aß40 (US-FDA; CE-IVDR) and p-tau181 (CE-IVDR) methods. The commutability of four CRM, at three concentrations, was assessed across assays. FINDINGS: Plasma p-tau217 consistently demonstrated higher fold-changes between AD and non-AD pathology groups, compared to other p-tau epitopes. Fujirebio LUMIPULSE G, UGOT IPMS, and Lilly MSD p-tau217 assays provided the highest median fold-changes. In CSF, p-tau217 assays also performed best, and exhibited substantially larger fold-changes than their plasma counterparts, despite similar diagnostic performance. P-tau217 showed the strongest correlations between plasma assays (rho=0.81 to 0.97). Plasma p-tau levels were weakly-to-moderately correlated with CSF p-tau, and correlations were non-significant within the AD group alone. The evaluated CRM were not commutable across assays. INTERPRETATION: Plasma p-tau217 measures had larger fold-changes and discriminative accuracies for detecting AD pathology, and better agreement across platforms than other plasma p-tau variants. Plasma and CSF markers of p-tau, measured by immunoassays, are not substantially correlated, questioning the interchangeability of their continuous relationship. Further work is warranted to understand the pathophysiology underlying this dissociation, and to develop suitable reference materials facilitating cross-assay standardisation. FUNDING: Alzheimer's Association (#ADSF-24-1284328-C).

11.
ACS Meas Sci Au ; 3(6): 488-495, 2023 Dec 20.
Article in English | MEDLINE | ID: mdl-38145030

ABSTRACT

By utilizing a high-temperature superconducting quantum interference device (high-Tc SQUID) magnetometer, an alternating current (AC) magnetosusceptometer, referred to as an analyzer, was developed for ultrasensitive immunoassays. The analyzer has been applied to assay biomarkers in human plasma associated with Alzheimer's disease (AD) and Parkinson's disease (PD). The involved assay methodology is the so-called immunomagnetic reduction (IMR). Such an analyzer has been approved for clinical use in Taiwan and Europe. The mass production of the analyzer is needed for clinical utilities. The issue of exploring analyzer-to-analyzer variations in the performances becomes critical. Unfortunately, there is no standard characterization to determine the variations in performances among analyzers. In this study, key characterizations, such as output signal stability, signal-to-noise ratio, measured concentrations of a control sample, etc., are proposed. In total, three analyzers are characterized in this work. The detected biomarkers include amyloid peptides, total tau protein, phosphorylated tau protein, and α-synuclein protein for AD and PD. Through one-way ANOVA for any of the characterizations among the three analyzers, it was found that there was no significant difference in any of these characterizations among the analyzers (p > 0.05). Furthermore, the three analyzers are applied to assay biomolecules for AD and PD in reference samples. High correlations (r > 0.8) in measured concentrations of any of these biomarkers in reference samples were obtained among the three analyzers. The results demonstrate that the proposed characterizations are feasible for achieving consistent performance among high-Tc SQUID-based AC magnetosusceptometers for assaying biomolecules.

12.
ACS Meas Sci Au ; 2(5): 485-492, 2022 Oct 19.
Article in English | MEDLINE | ID: mdl-36785659

ABSTRACT

With the demands of the high-throughput assay of biomarkers of ultralow concentrations in clinics, a 36-channel instrument utilizing immunomagnetic reduction (IMR) has been developed. The instrument involves the use of a high-T c superconducting-quantum-interference-device (SQUID) magnetometer to detect the signals due to the associations between target biomarker molecules and the antibody-functionalized magnetic nanoparticles in the reagent of IMR. In addition to illustrating the design and the measurements of the instrument, the assay characterizations for eight kinds of biomarkers related to neurodegenerative disease are investigated. Furthermore, the assay results among three independent instruments were compared. For an instrument, the channel-to-channel variations in measured concentrations of biomarkers are within a range of 2.09 to 5.62%. The assay accuracy was found to be from 99 to 103.7%. The p values in measured concentrations for any of the tested biomarkers were higher than 0.05 among the three instruments. The results demonstrate high throughput, high stability, and high consistency for the SQUID-IMR instruments.

13.
Dement Geriatr Cogn Dis Extra ; 12(2): 82-89, 2022.
Article in English | MEDLINE | ID: mdl-35702342

ABSTRACT

Background: For assays using immunomagnetic reduction, a reagent composed of antibody-functionalized magnetic nanoparticles is dispersed in phosphate-buffered saline solution. The real-time signals of alternating-current (ac) magnetic susceptibility, χac, of the reagent are subsequently recorded after mixing the reagent with a biofluid sample. After mixing the reagent and sample, the reduction in χac of the mixture is calculated and used to quantify the concentration of the target biomarker in the sample. The reduction does not occur immediately but rather occurs at some time after mixing. This observation implies that the time elapsed before recording the real-time signals of χac of a reagent-sample mixture needs to be investigated to ensure that the signals are fully recorded. In this work, the effect of time to detection on the measured concentrations of proteins in human plasma after mixing the reagent and sample is examined. Methods: The proteins analyzed are related to Alzheimer's disease: amyloid ß 1-40, amyloid ß 1-42, and Tau protein. The investigated times to detection after the mixing the reagent and sample are 0, 20, 30, 40, and 120 min. Results: The results show that the recording of real-time signals of χac should be conducted within 20 min after mixing the reagent and sample.

14.
Front Aging Neurosci ; 14: 920591, 2022.
Article in English | MEDLINE | ID: mdl-35663565

ABSTRACT

Background: An abnormal increase of α-synuclein in the brain is the hallmark of dementia with Lewy bodies (DLB). However, the diagnostic power of plasma α-synuclein in DLB is not yet confirmed. Parkinsonism is highly associated with and is one of the core clinical features of DLB. We studied plasma α-synuclein and developed a novel tool that combined plasma α-synuclein level and Motor Dysfunction Questionnaire (MDQ), namely Synuclein Motor Dysfunction Composite Scale (SMDCS), for the clinical discrimination of DLB from Alzheimer's disease (AD). Methods: This cross-sectional study analyzed participants' demographical data, plasma α-synuclein level, MDQ, structured clinical history questionnaire, neuropsychological and motor function tests, and neuroimaging studies. The power of plasma α-synuclein level, MDQ, and SMDCS for discriminating DLB from non-demented controls (NC) or AD were compared. Results: Overall, 121 participants diagnosed as 58 DLB, 31 AD, and 31 NC were enrolled. Patients with DLB had significantly higher mean plasma α-synuclein level (0.24 ± 0.32 pg/ml) compared to the NC group (0.08 ± 0.05 pg/ml) and the AD group (0.08 ± 0.05 pg/ml). The DLB group demonstrated higher MDQ (2.95 ± 1.60) compared to the NC (0.42 ± 0.98) or AD (0.44 ± 0.99) groups. The sensitivity/specificity of plasma α-synuclein level, MDQ, and SMDCS for differentiating DLB from non-DLB were 0.80/0.64, 0.83/0.89, and 0.88/0.93, respectively. Conclusion: Both plasma α-synuclein and MDQ were significantly higher in patients with DLB compared to the NC or AD groups. The novel SMDCS, significantly improved accuracy for the clinical differentiation of DLB from AD or NC.

15.
Sci Rep ; 12(1): 17919, 2022 10 26.
Article in English | MEDLINE | ID: mdl-36289355

ABSTRACT

Amyloid plaques and tau tangles are pathological hallmarks of Alzheimer's disease (AD). Parkinson's disease (PD) results from the accumulation of α-synuclein. TAR DNA-binding protein (TDP-43) and total tau protein (T-Tau) play roles in FTD pathology. All of the pathological evidence was found in the biopsy. However, it is impossible to perform stein examinations in clinical practice. Assays of biomarkers in plasma would be convenient. It would be better to investigate the combinations of various biomarkers in AD, PD and FTD. Ninety-one subjects without neurodegenerative diseases, 76 patients with amnesic mild cognitive impairment (aMCI) or AD dementia, combined as AD family, were enrolled. One hundred and nine PD patients with normal cognition (PD-NC) or dementia (PDD), combined as PD family, were enrolled. Twenty-five FTD patients were enrolled for assays of plasma amyloid ß 1-40 (Aß1-40), Aß1-42, T-Tau, α-synuclein and TDP-43 using immunomagnetic reduction (IMR). The results show that Aßs and T-Tau are major domains in AD family. α-synuclein is highly dominant in PD family. FTD is closely associated with TDP-43 and T-Tau. The dominant plasma biomarkers in AD family, PD family and FTD are consistent with pathology. This implies that plasma biomarkers are promising for precise and differential assessments of AD, PD and FTD in clinical practice.


Subject(s)
Alzheimer Disease , Frontotemporal Dementia , Parkinson Disease , Humans , Amyloid beta-Peptides , Alzheimer Disease/diagnosis , Frontotemporal Dementia/diagnosis , alpha-Synuclein , tau Proteins , Parkinson Disease/diagnosis , Peptide Fragments , Biomarkers , DNA-Binding Proteins
16.
Biosensors (Basel) ; 12(10)2022 Oct 17.
Article in English | MEDLINE | ID: mdl-36291020

ABSTRACT

Alzheimer's disease (AD) is the most common form of dementia. The most convincing biomarkers in the blood for AD are currently ß-amyloid (Aß) and Tau protein because amyloid plaques and neurofibrillary tangles are pathological hallmarks in the brains of patients with AD. The development of assay technologies in diagnosing early-stage AD is very important. The study of human AD subjects is hindered by ethical and technical limitations. Thus, many studies have therefore turned to AD animal models, such as Drosophila melanogaster, to explore AD pathology. However, AD biomarkers such as Aß and p-Tau protein in Drosophilamelanogaster occur at extremely low levels and are difficult to detect precisely. In this study, we applied the immunomagnetic reduction (IMR) technology of nanoparticles for the detection of p-Tau expressions in hTauR406W flies, an AD Drosophila model. Furthermore, we used IMR technology as a biosensor in the therapeutic evaluation of Chinese herbal medicines in hTauR406W flies with Tau-induced toxicity. To uncover the pathogenic pathway and identify therapeutic interventions of Chinese herbal medicines in Tau-induced toxicity, we modeled tauopathy in the notum of hTauR406W flies. Our IMR data showed that the selected Chinese herbal medicines can significantly reduce p-Tau expressions in hTauR406W flies. Using evidence of notal bristle quantification and Western blotting analysis, we confirmed the validity of the IMR data. Thus, we suggest that IMR can serve as a new tool for measuring tauopathy and therapeutic evaluation of Chinese herbal medicine in an AD Drosophila model.


Subject(s)
Alzheimer Disease , Biosensing Techniques , Drugs, Chinese Herbal , Tauopathies , Animals , Humans , tau Proteins , Alzheimer Disease/drug therapy , Alzheimer Disease/pathology , Drosophila/metabolism , Drugs, Chinese Herbal/therapeutic use , Drosophila melanogaster/metabolism , Tauopathies/drug therapy , Amyloid beta-Peptides , Technology
17.
Sci Rep ; 12(1): 1192, 2022 01 24.
Article in English | MEDLINE | ID: mdl-35075194

ABSTRACT

Subjects with comorbidities are at risk for neurodegeneration. There is a lack of a direct relationship between comorbidities and neurodegeneration. In this study, immunomagnetic reduction (IMR) assays were utilized to assay plasma Aß1-42 and total tau protein (T-Tau) levels in poststroke (PS, n = 27), family history of Alzheimer's disease (ADFH, n = 35), diabetes (n = 21), end-stage renal disease (ESRD, n = 41), obstructive sleep apnea (OSA, n = 20), Alzheimer's disease (AD, n = 65). Thirty-seven healthy controls (HCs) were enrolled. The measured concentrations of plasma Aß1-42 were 14.26 ± 1.42, 15.43 ± 1.76, 15.52 ± 1.60, 16.15 ± 1.05, 16.52 ± 0.59, 15.97 ± 0.54 and 20.06 ± 3.09 pg/mL in HC, PS, ADFH, diabetes, ESRD, OSA and AD groups, respectively. The corresponding concentrations of plasma T-Tau were 15.13 ± 3.62, 19.29 ± 8.01, 17.93 ± 6.26, 19.74 ± 2.92, 21.54 ± 2.72, 20.17 ± 2.77 and 41.24 ± 14.64 pg/mL. The plasma levels of Aß1-42 and T-Tau in were significantly higher in the PS, ADFH, diabetes, ESRD and OSA groups than controls (Aß1-42 in PS: 15.43 ± 1.76 pg/mL vs. 14.26 ± 1.42 pg/mL, p < 0.005; T-Tau in PS: 19.29 ± 8.01 vs. 15.13 ± 3.62 pg/mL, p < 0.005, Aß1-42 in ADFH: 15.52 ± 1.60 pg/mL vs. 14.26 ± 1.42 pg/mL, p < 0.001; T-Tau in ADFH: 17.93 ± 6.26 vs. 15.13 ± 3.62 pg/mL, p < 0.005, Aß1-42 in diabetes: 16.15 ± 1.05 pg/mL vs. 14.26 ± 1.42 pg/mL, p < 0.001; T-Tau in diabetes: 19.74 ± 2.92 vs. 15.13 ± 3.62 pg/mL, p < 0.001, Aß1-42 in ESRD: 16.52 ± 0.59 pg/mL vs. 14.26 ± 1.42 pg/mL, p < 0.001; T-Tau in ESRD: 21.54 ± 2.72 vs. 15.13 ± 3.62 pg/mL, p < 0.001, Aß1-42 in OSA: 15.97 ± 0.54 pg/mL vs. 14.26 ± 1.42 pg/mL, p < 0.001; T-Tau in OSA: 20.17 ± 2.77 vs. 15.13 ± 3.62 pg/mL, p < 0.001). This evidence indicates the high risk for dementia in these groups from the perspective of plasma biomarkers.


Subject(s)
Amyloid beta-Peptides/blood , Dementia/blood , Peptide Fragments/blood , tau Proteins/blood , Adult , Aged , Aged, 80 and over , Biomarkers/blood , Case-Control Studies , Cognition , Dementia/etiology , Diabetes Complications/blood , Female , Humans , Kidney Failure, Chronic/blood , Kidney Failure, Chronic/complications , Male , Middle Aged , Risk Assessment , Sleep Apnea, Obstructive/blood , Sleep Apnea, Obstructive/complications , Stroke/blood , Stroke/complications
18.
Plants (Basel) ; 11(4)2022 Feb 21.
Article in English | MEDLINE | ID: mdl-35214904

ABSTRACT

Alzheimer's disease (AD), a main cause of dementia, is the most common neurodegenerative disease that is related to the abnormal accumulation of amyloid ß (Aß) proteins. Yi-Gan-San (YGS), a traditional herbal medicine, has been used for the management of neurodegenerative disorders and for the treatment of neurosis, insomnia and dementia. The aim of this study was to examine antioxidant capacity and cytotoxicity of YGS treatment by using 2,2-Diphenyl-1-picrylhydrazyl (DPPH) and 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assays in vitro. We explored neuroprotective effects of YGS treatment in alleviating Aß neurotoxicity of Drosophila melanogaster in vivo by comparing survival rate, climbing index, and Aß expressions through retinal green fluorescent protein (GFP) expression, highly sensitive immunomagnetic reduction (IMR) and Western blotting assays. In the in vitro study, our results showed that scavenging activities of free radical and SH-SY5Y nerve cell viability were increased significantly (p < 0.01-0.05). In the in vivo study, Aß42-expressing flies (Aß42-GFP flies) and their WT flies (mCD8-GFP flies) were used as an animal model to examine the neurotherapeutic effects of YGS treatment. Our results showed that, in comparison with those Aß42 flies under sham treatments, Aß42 flies under YGS treatments showed a greater survival rate, better climbing speed, and lower Aß42 aggregation in Drosophila brain tissue (p < 0.01). Our findings suggest that YGS should have a beneficial alternative therapy for AD and dementia via alleviating Aß neurotoxicity in the brain tissue.

19.
Front Aging Neurosci ; 13: 759182, 2021.
Article in English | MEDLINE | ID: mdl-34858161

ABSTRACT

The potential biomarkers of Parkinson's disease are α-synuclein and neurofilament light chain (NFL). However, inconsistent preanalytical preparation of plasma could lead to variations in levels of these biomarkers. Different types of potassium salts of EDTA and different centrifugation temperatures during plasma preparation may affect the results of α-synuclein and NFL measurements. In this study, we prepared plasma from eight patients with Parkinson's disease (PD) and seven healthy controls (HCs) by using di- and tri-potassium (K2- and K3-) EDTA tubes and recruited a separated cohort with 42 PD patients and 40 HCs for plasma samples prepared from whole blood by centrifugation at room temperature and 4°C, respectively, in K2-EDTA tubes. The plasma levels of α-synuclein and NFL in K2- and K3-EDTA were similar. However, the levels of α-synuclein in the plasma prepared at 4°C (101.57 ± 43.43 fg/ml) were significantly lower compared with those at room temperature (181.23 ± 196.31 fg/ml, P < 0.001). Room temperature preparation demonstrated elevated plasma levels of α-synuclein in PD patients (256.6 ± 50.2 fg/ml) compared with the HCs (102.1 ± 0.66 fg/ml, P < 0.001), whereas this increase in PD was not present by preparation at 4°C. Both plasma preparations at room temperature and 4°C demonstrated consistent results of NFL, which are increased in PD patients compared with HCs. Our findings confirmed that K2- and K3-EDTA tubes were interchangeable for analyzing plasma levels of α-synuclein and NFL. Centrifugation at 4°C during plasma preparation generates considerable reduction and variation of α-synuclein level that might hinder the detection of α-synuclein level changes in PD.

20.
ACS Chem Neurosci ; 12(8): 1376-1383, 2021 04 21.
Article in English | MEDLINE | ID: mdl-33825443

ABSTRACT

Beta-amyloid (Aß1-42) triggers the phosphorylation of tau protein in Alzheimer's disease (AD), but the relationship between phosphorylated tau (p-tau) and Aß1-42 in the blood is not elucidated. We investigated the association in individuals with AD (n = 62, including amnesic mild cognitive impairment and dementia), Parkinson's disease (n = 30), frontotemporal dementia (n = 25), and cognitively unimpaired controls (n = 41) using immunomagnetic reduction assays to measure plasma Aß1-42 and p-tau181 concentrations. Correlation and regression analyses were performed to examine the relation between plasma levels, demographic factors, and clinical severity. Both plasma Aß1-42 and p-tau concentrations were significantly higher in AD and frontotemporal dementia than in the controls and Parkinson's disease. A significant positive association was found between plasma p-tau and Aß1-42 in controls (r = 0.579, P < 0.001) and AD (r = 0.699, P < 0.001) but not in frontotemporal dementia or Parkinson's disease. Plasma p-tau was significantly associated with clinical severity in the AD in terms of scores of clinical dementia rating (r = 0.288, P = 0.025) and mini-mental state examination (r = -0.253, P = 0.049). Regression analysis showed that plasma Aß1-42 levels explain approximately 47.7% of the plasma p-tau levels in the AD after controlling age, gender, and clinical severity. While in non-AD participants, the clinical dementia rating explained about 47.5% of the plasma p-tau levels. The disease-specific association between plasma Aß1-42 and p-tau levels in AD implies a possible synergic effect in mechanisms involving these two pathological proteins' genesis.


Subject(s)
Alzheimer Disease , Frontotemporal Dementia , Parkinson Disease , Amyloid beta-Peptides , Biomarkers , Humans , Peptide Fragments , tau Proteins
SELECTION OF CITATIONS
SEARCH DETAIL