Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Mikrochim Acta ; 190(6): 206, 2023 05 10.
Article in English | MEDLINE | ID: mdl-37162685

ABSTRACT

Using gold (Au) nanoparticle decorated Ti3C2Tx (Ti3C2Tx-Au) nanocomposites, a highly sensitive electrochemical aptasensor for the effective detection of chloramphenicol has been developed. As a two-dimensional layered material, the prepared composite not only provides high surface area, good conductivity, and thermal stability but also substantial binding sites for aptamers with high sensitivity and selectivity for the accurate determination of chloramphenicol. Interestingly, the conductivity and active sites were enhanced by freeze-drying Ti3C2Tx and in situ formation of Ti3C2Tx-Au nanocomposite. The fabricated aptasensor exhibited a very low detection limit (S/N ≥ 3) of 13.18 fg mL-1 with a linear range of 1 ~ 700 pg mL-1 and correlation coefficient of 0.9992. The fabricated aptasensor demonstrated an excellent reproducibility, repeatability, long-term stability, and high selectivity toward chloramphenicol. Further, the aptasensor was applied to real milk samples, and the recoveries were ranged from 98.93 to 101.93%.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Metal Nanoparticles , Nanocomposites , Chloramphenicol , Gold/chemistry , Metal Nanoparticles/chemistry , Reproducibility of Results , Aptamers, Nucleotide/chemistry , Biosensing Techniques/methods , Electrochemical Techniques/methods , Titanium , Nanocomposites/chemistry
2.
Mikrochim Acta ; 189(9): 332, 2022 08 15.
Article in English | MEDLINE | ID: mdl-35971003

ABSTRACT

A strand displacement-based "signal-off" electrochemical aptasensor is reported for the detection of Mucin 1 (MUC 1) based on a high original signal. Different from the conventional "signal-off" electrochemical biosensors where electrochemical substances are dispersed in electrolyte solution, here the current signal was generated by the complementary probe (CP) associated with ferrocene (Fc) labeled aptamer (Apt.-Fc). Because Apt.-Fc and MUC 1 have a higher affinity, Apt.-Fc dissociates from CP in the presence of MUC 1, resulting in a reduction of detection current signal generated by oxidation of labeled Fc. In this system, high detection signal is necessary to improve the sensor's performance. For this aim, a strategy is proposed for changing the modalities of electron transport and the quantity of Apt.-Fc introduced by simply tuning the sequence constitution of CP. As expected, a high detection current signal was obtained after selecting CP(Apt.-Fc)-TTT as the optimal CP. The aptasensor was then employed to detect MUC 1, and satisfactory detection results with a low detection limit (LOD) of 0.087 pM (S/N = 3), good specificity, good stability, and feasibility of detection of MUC 1 in artificial serum (recovery of 92-101%, RSD of 1.36-5.23%) were obtained.


Subject(s)
Aptamers, Nucleotide , Mucin-1 , Aptamers, Nucleotide/chemistry , Electrochemical Techniques/methods , Limit of Detection , Metallocenes/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL