Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Ann Fr Anesth Reanim ; 29(10): 704-9, 2010 Oct.
Article in French | MEDLINE | ID: mdl-20729032

ABSTRACT

INTRODUCTION: We designed written information concerning two medical imaging techniques: the computed tomography scanner and the magnetic resonance imaging (MRI), and we evaluated the quality of the information in particular its readability. METHODS: Written information concerning scanner and MRI were elaborate starting from a reference frame based on a lexicon of the good practices. The written information sheets were initially reviewed by eight doctors, 45 nurses and by 26 couples of parents of hospitalized children, and finally by the communication and juridical services of our hospital. They were asked to improve the lexico-syntactic readability in order to increase the comprehension of the written information. Seventy-two couples of parents of hospitalized children who had not taken part of the protocol before evaluated the final version of the documents. The quality of the documents was evaluated using the scores of readability of Flesch and the Flesch-Kincaid, and a questionnaire of comprehension, managed before and after the delivery of written information. RESULTS: A total of 144 persons participated in the study. The number of right answers after reading written information increased by 38 % and by 35 % for the scanner and MRI information's respectively. Flesch and Flesch-Kincaid scores were not improved in the revised version of the written information compared to the first version. CONCLUSION: Although readability scores for information sheets were low, our results suggest that they brought information, which contributed to a better understanding of these two medical imaging techniques by parents.


Subject(s)
Information Dissemination/methods , Magnetic Resonance Imaging , Nervous System Diseases/diagnosis , Tomography, X-Ray Computed , Writing , Child , Humans , Quality Control
2.
Clin Exp Pharmacol Physiol ; 28(12): 983-5, 2001 Dec.
Article in English | MEDLINE | ID: mdl-11903298

ABSTRACT

1. The present study examined the origin of the 0.4 Hz rhythm in renal sympathetic nerve activity (RSNA) in rats. It was anticipated that, after elimination of 0.4 Hz oscillations of arterial pressure (AP) by alpha-adrenoceptor blockade, the persistence or disappearance of a 0.4 Hz rhythm in RSNA would point to an endogenous (central oscillator) or baroreflex origin, respectively. 2. Arterial pressure and RSNA were recorded in seven conscious rats, before and after acute alpha-adrenoceptor blockade with phentolamine (5 mg/kg, i.v.). In each condition, power and coherence spectra were calculated over 15 min periods of rest. 3. In control conditions, highly coherent AP and RSNA oscillations were observed near 0.4 Hz. After phentolamine administration, spectral power in the mid-frequency (0.27-0.74 Hz) band was significantly reduced for both AP and RSNA and maximum power was shifted towards 0.7 Hz. 4. The disappearance of the RSNA rhythm at 0.4 Hz after phentolamine administration favours the hypothesis of a baroreflex origin. The new oscillation near 0.7 Hz can derive either from the activity of a previously unrecognized central oscillator or from a faster feedback mechanism involving cotransmitters of noradrenaline acting with shorter time constants (e.g. ATP).


Subject(s)
Adrenergic alpha-Antagonists/pharmacology , Kidney/drug effects , Kidney/innervation , Phentolamine/pharmacology , Sympathetic Nervous System/drug effects , Animals , Blood Pressure/drug effects , Consciousness , Male , Rats , Rats, Sprague-Dawley , Sympathetic Nervous System/physiology
SELECTION OF CITATIONS
SEARCH DETAIL