Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 237
Filter
Add more filters

Publication year range
1.
J Surg Res ; 295: 131-138, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38007860

ABSTRACT

INTRODUCTION: Counseling patients and parents about the postoperative recovery expectations for physical activity after pediatric appendectomy varies significantly and is not specific to patients' demographic characteristics. Consumer wearable devices (CWD) can be used to objectively assess patients' normative postoperative recovery of physical activity. This study aimed to develop demographic-specific normative physical activity recovery trajectories using CWD in pediatric patients undergoing appendectomy. METHODS: Children ages 3-18 y old undergoing laparoscopic appendectomy for acute appendicitis were recruited. Patients wore a Fitbit device for 21 d postoperatively and daily step counts were measured. Patients with postoperative complications were excluded. Segmented regression models were fitted and time-to-plateau was estimated for patients with simple and complicated appendicitis separately for each age group, sex, race/ethnicity, and body mass index category. RESULTS: Among 147 eligible patients; 76 (51.7%) were female, 86 (58.5%) were in the younger group, and 79 (53.7%) had complicated appendicitis. Patients 3-11 y old demonstrated a faster trajectory to a physical activity plateau compared to those 12-18 in both simple (postoperative day [POD] 9 versus POD 17) and complicated appendicitis (POD 17 versus POD 21). Males and females had a similar postoperative recovery trajectory in simple and complicated appendicitis. There was no clear pattern differentiating trajectories based on race/ethnicity. Overweight/obese patients demonstrated a slower recovery trajectory in simple appendicitis. CONCLUSIONS: This study demonstrates that factors other than the disease itself, such as age, may affect recovery, suggesting the need for more tailored discharge instructions. CWDs can improve our understanding of recovery and allow for better data-driven counseling perioperatively.


Subject(s)
Appendicitis , Laparoscopy , Wearable Electronic Devices , Male , Humans , Child , Female , Appendectomy/adverse effects , Appendicitis/surgery , Appendicitis/complications , Laparoscopy/adverse effects , Retrospective Studies , Postoperative Complications/etiology , Demography , Length of Stay
2.
J Surg Res ; 295: 853-861, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38052697

ABSTRACT

INTRODUCTION: Markers of postoperative recovery in pediatric patients are difficult for parents to evaluate after hospital discharge, who use subjective proxies to assess recovery and the onset of complications. Consumer-grade wearable devices (e.g., Fitbit) generate objective recovery data in near real time and thus may provide an opportunity to remotely monitor postoperative patients and identify complications beyond the initial hospitalization. The aim of this study was to use daily step counts from a Fitbit to compare recovery in patients with complications to those without complications after undergoing appendectomy for complicated appendicitis. METHODS: Children ages 3-17 years old undergoing laparoscopic appendectomy for complicated appendicitis were recruited. Patients wore a Fitbit device for 21 d after operation. After collection, patient data were included in the analysis if minimum wear-time criteria were achieved. Postoperative complications were identified through chart review, and step count trajectories for patients recovering with and without complications were compared. Additionally, to account for the patients experiencing a complication on different postoperative days, median daily step count for pre- and post-complication were analyzed. RESULTS: Eighty-six patients with complicated appendicitis were enrolled in the study, and fourteen children developed a postoperative complication. Three patients were excluded because they did not meet the minimum wear time requirements. Complications were divided into abscesses (n = 7, 64%), surgical site infections (n = 2, 18%), and other, which included small bowel obstruction and Clostridioides difficile infection (n = 2, 18%). Patients presented with a complication on mean postoperative day 8, while deviation from the normative recovery trajectory was evident 4 d prior. When compared to children with normative recovery, the patients with surgical complications experienced a slower increase in step count postoperatively, but the recovery trajectory was specific to each complication type. When corrected for day of presentation with complication, step count remained low prior to the discovery of the complication and increased after treatment resembling the normative recovery trajectory. CONCLUSIONS: This study profiled variations from the normative recovery trajectory in patients with complication after appendectomy for complicated appendicitis, with distinct trajectory patterns by complication type. Our findings have potentially profound clinical implications for monitoring pediatric patients postoperatively, particularly in the outpatient setting, thus providing objective data for potentially earlier identification of complications after hospital discharge.


Subject(s)
Appendicitis , Laparoscopy , Wearable Electronic Devices , Humans , Child , Child, Preschool , Adolescent , Appendectomy/adverse effects , Appendicitis/surgery , Appendicitis/complications , Laparoscopy/adverse effects , Hospitalization , Postoperative Complications/diagnosis , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Retrospective Studies , Length of Stay
3.
J Surg Oncol ; 129(4): 827-834, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38115237

ABSTRACT

BACKGROUND: Postoperative inpatients experience increased stress due to pain and poor restorative sleep than non-surgical inpatients. OBJECTIVES AND METHODS: A total of 101 patients, undergoing major oncologic surgery, were randomized to a postoperative sleep protocol (n = 50) or standard postoperative care (n = 51), between August 2020 and November 2021. The primary endpoint of the study was postoperative sleep time after major oncologic surgery. Sleep time and steps were measured using a Fitbit Charge 4®. RESULTS: There was no statistically significant difference found in postoperative sleep time between the sleep protocol and standard group (median sleep time of 427 min vs. 402 min; p = 0.852, respectively). Major complication rates were similar in both groups (7.4% vs. 8.9%). Multivariate analysis found sex and Charlson Comorbidity Index to be significant factors affecting postoperative sleep time and step count. Postoperative delirium was only observed in the standard group, although this did not reach statistical significance. There were no in hospital mortalities. CONCLUSION: The use of a sleep protocol was found to be safe in our study population. There was no statistical difference in postoperative sleep time or major complications. Institution of a more humane sleep protocol for postoperative inpatients should be considered.


Subject(s)
Neoplasms , Sleep , Humans , Hospitals , Neoplasms/surgery , Postoperative Complications/epidemiology , Randomized Controlled Trials as Topic
4.
Clin Trials ; : 17407745241230287, 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38486348

ABSTRACT

BACKGROUND/AIMS: Information regarding the use of wearable devices in clinical research, including disease areas, intervention techniques, trends in device types, and sample size targets, remains elusive. Therefore, we conducted a comprehensive review of clinical research trends related to wristband wearable devices in research planning and examined their applications in clinical investigations. METHODS: As this study identified trends in the adoption of wearable devices during the planning phase of clinical research, including specific disease areas and targeted number of intervention cases, we searched ClinicalTrials.gov-a prominent platform for registering and disseminating clinical research. Since wrist-worn devices represent a large share of the market, we focused on wrist-worn devices and selected the most representative models among them. The main analysis focused on major wearable devices to facilitate data analysis and interpretation, but other wearables were also surveyed for reference. We searched ClinicalTrials.gov with the keywords "ActiGraph,""Apple Watch,""Empatica,""Fitbit,""Garmin," and "wearable devices" to obtain studies published up to 21 August 2022. This initial search yielded 3214 studies. After excluding duplicate National Clinical Trial studies (the overlap was permissible among different device types except for wearable devices), our analysis focused on 2930 studies, including simple, time-series, and type-specific assessments of various variables. RESULTS: Overall, an increasing number of clinical studies have incorporated wearable devices since 2012. While ActiGraph and Fitbit initially dominated this landscape, the use of other devices has steadily increased, constituting approximately 10% of the total after 2015. Observational studies outnumbered intervention studies, with behavioral and device-based interventions being particularly prevalent. Regarding disease types, cancer and cardiovascular diseases accounted for approximately 20% of the total. Notably, 114 studies adopted multiple devices simultaneously within the context of their clinical investigations. CONCLUSIONS: Our findings revealed that the utilization of wearable devices for data collection and behavioral interventions in various disease areas has been increasing over time since 2012. The increase in the number of studies over the past 3 years has been particularly significant, suggesting that this trend will continue to accelerate in the future. Devices and their evaluation methods that have undergone thorough validation, confirmed their accuracy, and adhered to established legal regulations will likely assume a pivotal role in evaluations, allowing for remote clinical trials. Moreover, behavioral intervention therapy utilizing apps is becoming more extensive, and we expect to see more examples that will lead to their approval as programmed medical devices in the future.

5.
BMC Public Health ; 24(1): 927, 2024 Mar 31.
Article in English | MEDLINE | ID: mdl-38556892

ABSTRACT

BACKGROUND: The escalating global prevalence of type 2 diabetes and prediabetes presents a major public health challenge. Physical activity plays a critical role in managing (pre)diabetes; however, adherence to physical activity recommendations remains low. The ENERGISED trial was designed to address these challenges by integrating mHealth tools into the routine practice of general practitioners, aiming for a significant, scalable impact in (pre)diabetes patient care through increased physical activity and reduced sedentary behaviour. METHODS: The mHealth intervention for the ENERGISED trial was developed according to the mHealth development and evaluation framework, which includes the active participation of (pre)diabetes patients. This iterative process encompasses four sequential phases: (a) conceptualisation to identify key aspects of the intervention; (b) formative research including two focus groups with (pre)diabetes patients (n = 14) to tailor the intervention to the needs and preferences of the target population; (c) pre-testing using think-aloud patient interviews (n = 7) to optimise the intervention components; and (d) piloting (n = 10) to refine the intervention to its final form. RESULTS: The final intervention comprises six types of text messages, each embodying different behaviour change techniques. Some of the messages, such as those providing interim reviews of the patients' weekly step goal or feedback on their weekly performance, are delivered at fixed times of the week. Others are triggered just in time by specific physical behaviour events as detected by the Fitbit activity tracker: for example, prompts to increase walking pace are triggered after 5 min of continuous walking; and prompts to interrupt sitting following 30 min of uninterrupted sitting. For patients without a smartphone or reliable internet connection, the intervention is adapted to ensure inclusivity. Patients receive on average three to six messages per week for 12 months. During the first six months, the text messaging is supplemented with monthly phone counselling to enable personalisation of the intervention, assistance with technical issues, and enhancement of adherence. CONCLUSIONS: The participatory development of the ENERGISED mHealth intervention, incorporating just-in-time prompts, has the potential to significantly enhance the capacity of general practitioners for personalised behavioural counselling on physical activity in (pre)diabetes patients, with implications for broader applications in primary care.


Subject(s)
Cell Phone , Diabetes Mellitus, Type 2 , General Practice , Prediabetic State , Telemedicine , Humans , Diabetes Mellitus, Type 2/prevention & control , Diabetes Mellitus, Type 2/epidemiology , Prediabetic State/therapy , Sedentary Behavior , Exercise , Telemedicine/methods
6.
Sensors (Basel) ; 24(2)2024 Jan 19.
Article in English | MEDLINE | ID: mdl-38276327

ABSTRACT

The development of consumer sleep-tracking technologies has outpaced the scientific evaluation of their accuracy. In this study, five consumer sleep-tracking devices, research-grade actigraphy, and polysomnography were used simultaneously to monitor the overnight sleep of fifty-three young adults in the lab for one night. Biases and limits of agreement were assessed to determine how sleep stage estimates for each device and research-grade actigraphy differed from polysomnography-derived measures. Every device, except the Garmin Vivosmart, was able to estimate total sleep time comparably to research-grade actigraphy. All devices overestimated nights with shorter wake times and underestimated nights with longer wake times. For light sleep, absolute bias was low for the Fitbit Inspire and Fitbit Versa. The Withings Mat and Garmin Vivosmart overestimated shorter light sleep and underestimated longer light sleep. The Oura Ring underestimated light sleep of any duration. For deep sleep, bias was low for the Withings Mat and Garmin Vivosmart while other devices overestimated shorter and underestimated longer times. For REM sleep, bias was low for all devices. Taken together, these results suggest that proportional bias patterns in consumer sleep-tracking technologies are prevalent and could have important implications for their overall accuracy.


Subject(s)
Actigraphy , Sleep Wake Disorders , Young Adult , Humans , Polysomnography/methods , Actigraphy/methods , Reproducibility of Results , Sleep , Sleep Stages
7.
Am J Kidney Dis ; 82(1): 75-83, 2023 07.
Article in English | MEDLINE | ID: mdl-36801430

ABSTRACT

RATIONALE & OBJECTIVE: People with end-stage kidney disease (ESKD) have very low physical activity, and the degree of inactivity is strongly associated with morbidity and mortality. We assessed the feasibility and effectiveness of a 12-week intervention coupling a wearable activity tracker (FitBit) and structured feedback coaching versus wearable activity tracker alone on changes in physical activity in hemodialysis patients. STUDY DESIGN: Randomized controlled trial. SETTING & PARTICIPANTS: 55 participants with ESKD receiving hemodialysis who were able to walk with or without assistive devices recruited from a single academic hemodialysis unit between January 2019 and April 2020. INTERVENTIONS: All participants wore a Fitbit Charge 2 tracker for a minimum of 12 weeks. Participants were randomly assigned 1:1 to a wearable activity tracker plus a structured feedback intervention versus the wearable activity tracker alone. The structured feedback group was counseled weekly on steps achieved after randomization. OUTCOME: The outcome was step count, and the main parameter of interest was the absolute change in daily step count, averaged per week, from baseline to completion of 12 weeks intervention. In the intention-to-treat analysis, mixed-effect linear regression analysis was used to evaluate change in daily step count from baseline to 12-weeks in both arms. RESULTS: Out of 55 participants, 46 participants completed the 12-week intervention (23 per arm). The mean age was 62 (± 14 SD) years; 44% were Black, and 36% were Hispanic. At baseline, step count (structured feedback intervention: 3,704 [1,594] vs wearable activity tracker alone: 3,808 [1,890]) and other participant characteristics were balanced between the arms. We observed a larger change in daily step count in the structured feedback arm at 12 weeks relative to use of the wearable activity tracker alone arm (Δ 920 [±580 SD] versus Δ 281 [±186 SD] steps; between-group difference Δ 639 [±538 SD] steps; P<0.05). LIMITATIONS: Single-center study and small sample size. CONCLUSION: This pilot randomized controlled trial demonstrated that structured feedback coupled with a wearable activity tracker led to a greater daily step count that was sustained over 12 weeks relative to a wearable activity tracker alone. Future studies are required to determine longer-term sustainability of the intervention and potential health benefits in hemodialysis patients. FUNDING: Grants from industry (Satellite Healthcare) and government (National Institute for Diabetes and Digestive and Kidney Diseases (NIDDK). TRIAL REGISTRATION: Registered at ClinicalTrials.gov with study number NCT05241171.


Subject(s)
Exercise , Fitness Trackers , Humans , Middle Aged , Feedback , Pilot Projects , Renal Dialysis
8.
Mult Scler ; 29(3): 363-373, 2023 03.
Article in English | MEDLINE | ID: mdl-36573559

ABSTRACT

BACKGROUND: Remote activity monitoring has the potential to evaluate real-world, motor function, and disability at home. The relationships of daily physical activity with spinal cord white matter and gray matter (GM) areas, multiple sclerosis (MS) disability and leg function, are unknown. OBJECTIVE: Evaluate the association of structural central nervous system pathology with ambulatory disability. METHODS: Fifty adults with progressive or relapsing MS with motor disability who could walk >2 minutes were assessed using clinician-evaluated, patient-reported outcomes, and quantitative brain and spinal cord magnetic resonance imaging (MRI) measures. Fitbit Flex2, worn on the non-dominant wrist, remotely assessed activity over 30 days. Univariate and multivariate analyses were performed to assess correlations between physical activity and other disability metrics. RESULTS: Mean age was 53.3 years and median Expanded Disability Status Scale (EDSS) was 4.0. Average daily step counts (STEPS) were highly correlated with EDSS and walking measures. Greater STEPS were significantly correlated with greater C2-C3 spinal cord GM areas (ρ = 0.39, p = 0.04), total cord area (TCA; ρ = 0.35, p = 0.04), and cortical GM volume (ρ = 0.32, p = 0.04). CONCLUSION: These results provide preliminary evidence that spinal cord GM area is a neuroanatomical substrate associated with STEPS. STEPS could serve as a proxy to alert clinicians and researchers to possible changes in structural nervous system pathology.


Subject(s)
Cervical Cord , Disabled Persons , Motor Disorders , Multiple Sclerosis , Adult , Humans , Middle Aged , Multiple Sclerosis/pathology , Cervical Cord/pathology , Spinal Cord/pathology , Brain/pathology , Magnetic Resonance Imaging , Walking , Disability Evaluation , Atrophy/pathology
9.
Haemophilia ; 29(2): 658-667, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36723510

ABSTRACT

INTRODUCTION: Limited evidence exists on objectively measured habitual physical activity (PA) of young people with haemophilia (PWH). AIMS: To compare different outcomes of objective PA between young PWH A and controls using a commercial activity tracker. METHODS: We enrolled males aged 13-30 years with moderate and severe haemophilia A, without inhibitors on regular prophylaxis. PA was measured with the activity tracker Fitbit Charge 3 for 12 weeks. Control group data was obtained from ≈60,000 Fitbit users, matched on age, sex and measurement period. PA variables [steps, intensities, volume, activity types, exercise frequencies and proportion meeting the World Health Organization's moderate-to-vigorous PA (MVPA) recommendations] were compared between groups descriptively and using Welch's two-sample t-test and two-sample test of proportions. RESULTS: Forty PWH A were enrolled (mean age 19.5 years, 50% teenagers, 50% adults, three (7.5%) with moderate and 37 (92.5%) with severe haemophilia). Mean daily steps and minutes MVPA were similar between PWH and controls. PWH spent more time in light PA (mean 227 vs. 192 min/day, P = .033) and exercised more frequently (mean 5.6 vs. 3.9 exercise sessions/week, P < .001). Among teenagers, 40% PWH and 8% controls reached MVPA recommendations, compared to 95% and 100% among adults. The most common type of PA was walking. CONCLUSION: This cohort of young PWH A on prophylactic treatment had PA levels comparable to controls. Still, a considerable proportion of teenagers did not meet the recommended weekly volume of MVPA, and we encourage clinicians to have a particular focus on promoting PA for this group.


Subject(s)
Hemophilia A , Male , Humans , Young Adult , Adolescent , Adult , Hemophilia A/epidemiology , Exercise , Walking , Fitness Trackers
10.
J Surg Res ; 292: 7-13, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37567031

ABSTRACT

INTRODUCTION: The modified Nuss procedure is an elective procedure associated with a lengthy recovery, uncontrolled pain, and risk of infrequent, yet life-threatening complications. The absence of objective measures of normative postoperative recovery creates uncertainty about the postdischarge period, which remains highly dependent on the patients' and their caregivers' expectations and management of recovery. We aimed to describe an objective-normative, physical activity recovery trajectory after the modified Nuss procedure, using step counts from the Fitbit. METHODS: This observational study enrolled children ≤18 y with pectus excavatum who underwent the modified Nuss procedure from 2021 to 2022. The Fitbit was worn for 21 postoperative days. Postdischarge outcomes and health-care utilization were evaluated. For patients without postoperative complications, piecewise linear regression analysis was conducted to generate a normative recovery trajectory model of daily step counts. RESULTS: Of 80 patients enrolled, 66 (86%) met eligibility criteria (mean age, 15.1 ± 1.3 y; 89.4% male, 62.1% non-Hispanic White). The mean number of telephone and electronic message encounters regarding concerns with the patient's recovery within 30 d postoperatively was 2.1 (standard deviation = 2.7). Ten patients (15.2%) returned to the emergency department (ED) within the 30-d postoperative period. Seven patients (10.6%) presented to the ED one time, and three patients (4.5%) presented to the ED twice. Thirty-day readmission rate was four patients (6.0%). Piecewise regression model showed that patients without complications steadily increased their daily step count on each postoperative day and plateaued on day 18. CONCLUSIONS: We have developed a normative recovery trajectory following the modified Nuss procedure using step count data collected by a consumer wearable device. This offers the potential to inform preoperative patient expectations and reduce avoidable health-care utilization through informed preoperative counseling, thus laying the ground work for the use of consumer wearable devices as a postdischarge remote monitoring tool.

11.
Int J Geriatr Psychiatry ; 38(3): e5898, 2023 03.
Article in English | MEDLINE | ID: mdl-36814072

ABSTRACT

OBJECTIVES: Limited research on using smart wearables such as Fitbit devices among people with dementia has shown favourable outcomes. The aim of this study was to explore the acceptability and feasibility of using a Fitbit Charge 3 among people with dementia, living in the community, who took part in the physical exercise component of the Comprehensive REsilience-building psychoSocial intervenTion pilot study. METHODS: A mixed methods study was conducted; Quantitative data relating to wear rates for the Fitbit were recorded and qualitative data were collected by group and individual interviews with the people with dementia and their caregiver about their experience of wearing/using the Fitbit in the study. RESULTS: Nine people with dementia and their caregiver completed the intervention. Only one participant wore the Fitbit consistently. Supporting set-up and use of the devices was time consuming and caregiver involvement was essential for day-to-day support: none of the people with dementia owned a smartphone. Few of them engaged with the Fitbit features, primarily only using it to check the time and only a minority wanted to keep the device beyond the intervention. DISCUSSION: When designing a study using smart wearables such as a Fitbit among people with dementia, consideration should be given to the following: the possible burden on caregivers supporting the use of the device; a lack of familiarity with this technology in the target population; dealing with missing data, and the involvement of the researcher in setting up and supporting use of the device.


Subject(s)
Dementia , Fitness Trackers , Humans , Pilot Projects , Caregivers , Exercise
12.
BMC Public Health ; 23(1): 613, 2023 03 31.
Article in English | MEDLINE | ID: mdl-36997936

ABSTRACT

BACKGROUND: The growing number of patients with type 2 diabetes and prediabetes is a major public health concern. Physical activity is a cornerstone of diabetes management and may prevent its onset in prediabetes patients. Despite this, many patients with (pre)diabetes remain physically inactive. Primary care physicians are well-situated to deliver interventions to increase their patients' physical activity levels. However, effective and sustainable physical activity interventions for (pre)diabetes patients that can be translated into routine primary care are lacking. METHODS: We describe the rationale and protocol for a 12-month pragmatic, multicentre, randomised, controlled trial assessing the effectiveness of an mHealth intervention delivered in general practice to increase physical activity and reduce sedentary behaviour of patients with prediabetes and type 2 diabetes (ENERGISED). Twenty-one general practices will recruit 340 patients with (pre)diabetes during routine health check-ups. Patients allocated to the active control arm will receive a Fitbit activity tracker to self-monitor their daily steps and try to achieve the recommended step goal. Patients allocated to the intervention arm will additionally receive the mHealth intervention, including the delivery of several text messages per week, with some of them delivered just in time, based on data continuously collected by the Fitbit tracker. The trial consists of two phases, each lasting six months: the lead-in phase, when the mHealth intervention will be supported with human phone counselling, and the maintenance phase, when the intervention will be fully automated. The primary outcome, average ambulatory activity (steps/day) measured by a wrist-worn accelerometer, will be assessed at the end of the maintenance phase at 12 months. DISCUSSION: The trial has several strengths, such as the choice of active control to isolate the net effect of the intervention beyond simple self-monitoring with an activity tracker, broad eligibility criteria allowing for the inclusion of patients without a smartphone, procedures to minimise selection bias, and involvement of a relatively large number of general practices. These design choices contribute to the trial's pragmatic character and ensure that the intervention, if effective, can be translated into routine primary care practice, allowing important public health benefits. TRIAL REGISTRATION: ClinicalTrials.gov (NCT05351359, 28/04/2022).


Subject(s)
Diabetes Mellitus, Type 2 , General Practice , Prediabetic State , Telemedicine , Humans , Diabetes Mellitus, Type 2/prevention & control , Exercise , Multicenter Studies as Topic , Prediabetic State/therapy , Randomized Controlled Trials as Topic , Sedentary Behavior , Pragmatic Clinical Trials as Topic
13.
J Med Internet Res ; 25: e45975, 2023 07 19.
Article in English | MEDLINE | ID: mdl-37467013

ABSTRACT

BACKGROUND: Effective health interventions for North Korean refugees vulnerable to metabolic disorders are currently unelucidated. OBJECTIVE: This study aimed to evaluate the effects of digital health interventions in North Korean refugees using a wearable activity tracker (Fitbit device). METHODS: We conducted a prospective, randomized, open-label study on North Korean refugees aged 19-59 years between June 2020 and October 2021 with a 12-week follow-up period. The participants were randomly assigned to either an intervention group or a control group in a 1:1 ratio. The intervention group received individualized health counseling based on Fitbit data every 4 weeks, whereas the control group wore the Fitbit device but did not receive individualized counseling. The primary and secondary outcomes were the change in the mean daily step count and changes in the metabolic parameters, respectively. RESULTS: The trial was completed by 52 North Korean refugees, of whom 27 and 25 were in the intervention and control groups, respectively. The mean age was 43 (SD 10) years, and 41 (78.8%) participants were women. Most participants (44/52, 95.7%) had a low socioeconomic status. After the intervention, the daily step count in the intervention group increased, whereas that in the control group decreased. However, there were no significant differences between the 2 groups (+83 and -521 steps in the intervention and control groups, respectively; P=.500). The effects of the intervention were more prominent in the participants with a lower-than-average daily step count at baseline (<11,667 steps/day). After the 12-week study period, 85.7% (12/14) and 46.7% (7/15) of the participants in the intervention and control groups, respectively, had an increased daily step count (P=.05). The intervention prevented the worsening of the metabolic parameters, including BMI, waist circumference, fasting blood glucose level, and glycated hemoglobin level, during the study period. CONCLUSIONS: The wearable device-based physical activity intervention did not significantly increase the average daily step count in the North Korean refugees in this study. However, the intervention was effective among the North Korean refugees with a lower-than-average daily step count; therefore, a large-scale, long-term study of this intervention type in an underserved population is warranted. TRIAL REGISTRATION: Clinical Research Information Service KCT0007999; https://cris.nih.go.kr/cris/search/detailSearch.do/23622.


Subject(s)
Refugees , Wearable Electronic Devices , Humans , Female , Adult , Male , Pilot Projects , Prospective Studies , Democratic People's Republic of Korea , Exercise/psychology
14.
J Med Internet Res ; 25: e51336, 2023 12 13.
Article in English | MEDLINE | ID: mdl-38090797

ABSTRACT

BACKGROUND: Sleep disturbances are core symptoms of psychiatric disorders. Although various sleep measures have been developed to assess sleep patterns and quality of sleep, the concordance of these measures in patients with psychiatric disorders remains relatively elusive. OBJECTIVE: This study aims to examine the degree of agreement among 3 sleep recording methods and the consistency between subjective and objective sleep measures, with a specific focus on recently developed devices in a population of individuals with psychiatric disorders. METHODS: We analyzed 62 participants for this cross-sectional study, all having data for polysomnography (PSG), Zmachine, Fitbit, and sleep logs. Participants completed questionnaires on their symptoms and estimated sleep duration the morning after the overnight sleep assessment. The interclass correlation coefficients (ICCs) were calculated to evaluate the consistency between sleep parameters obtained from each instrument. Additionally, Bland-Altman plots were used to visually show differences and limits of agreement for sleep parameters measured by PSG, Zmachine, Fitbit, and sleep logs. RESULTS: The findings indicated a moderate agreement between PSG and Zmachine data for total sleep time (ICC=0.46; P<.001), wake after sleep onset (ICC=0.39; P=.002), and sleep efficiency (ICC=0.40; P=.006). In contrast, Fitbit demonstrated notable disagreement with PSG (total sleep time: ICC=0.08; wake after sleep onset: ICC=0.18; sleep efficiency: ICC=0.10) and exhibited particularly large discrepancies from the sleep logs (total sleep time: ICC=-0.01; wake after sleep onset: ICC=0.05; sleep efficiency: ICC=-0.02). Furthermore, subjective and objective concordance among PSG, Zmachine, and sleep logs appeared to be influenced by the severity of the depressive symptoms and obstructive sleep apnea, while these associations were not observed between the Fitbit and other sleep instruments. CONCLUSIONS: Our study results suggest that Fitbit accuracy is reduced in the presence of comorbid clinical symptoms. Although user-friendly, Fitbit has limitations that should be considered when assessing sleep in patients with psychiatric disorders.


Subject(s)
Sleep Wake Disorders , Sleep , Humans , Polysomnography/methods , Cross-Sectional Studies , Reproducibility of Results , Sleep Wake Disorders/diagnosis , Electroencephalography , Actigraphy/methods
15.
Rheumatology (Oxford) ; 61(7): 2951-2958, 2022 07 06.
Article in English | MEDLINE | ID: mdl-34528065

ABSTRACT

OBJECTIVES: Inflammatory myopathies are characterized by muscle weakness that limits the activities of daily living. Daily step count is an accepted metric of physical activity. Wearable technologies such as Fitbit® enable tracking of daily step counts. We assessed the psychometric properties of Fitbit® and compared the accuracy of Fitbit® step counts to ActiGraph®. METHODS: This was a pilot, proof of concept, prospective observational study with four visits at 0, 1, 3 and 6 months in PM, DM, necrotizing myopathy (NM) or anti-synthetase syndrome (AS) subjects. Six core set measures (manual muscle testing, physician global disease activity, patient global disease activity, and extra-muscular disease activity, HAQ-Disability Index and creatine kinase), three functional tests (six-min walk, timed up-and-go, sit-to-stand tests) and SF-36 physical function-10 (PF10) were collected at each visit. Patients wore waist-worn Fitbit® One and ActiGraph® T3X-BT concurrently for 7 days/month for 6 months. RESULTS: Twenty-four (10 DM, 8 PM/NM, 6 AS) patients (17 females/7 males; 91% Caucasian) were enrolled. Test-retest reliability of daily steps was strong in 1-month follow-up (ICC 0.89). Daily steps and peak 1-min cadence showed moderate-strong correlations with physician global disease activity, patient global disease activity, HAQ-Disability Index, SF-36 PF10 and all three functional tests. Fitbit® and ActiGraph® step counts demonstrated good agreement and strong correlation (ICC 0.96). CONCLUSION: Fitbit® daily steps and peak 1-min cadence are reliable and valid measures of physical activity in a cohort of myositis patients. This pilot data suggests that Fitbit® has a potential for use in clinical practice and trials to monitor physical activity in myositis patients, but larger studies are needed for further validation.


Subject(s)
Fitness Trackers , Myositis , Activities of Daily Living , Exercise/physiology , Female , Humans , Male , Monitoring, Ambulatory , Myositis/diagnosis , Reproducibility of Results
16.
Haemophilia ; 28(6): e172-e180, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35830613

ABSTRACT

INTRODUCTION: Measurement of physical activity (PA) using commercial activity trackers such as Fitbit devices has become increasingly popular, also for people with haemophilia (PWH). The accuracy of the Fitbit model Charge 3 has not yet been examined. AIMS: To compare the Fitbit Charge 3 against the research-grade accelerometer ActiGraph GT3X-BT in measuring average daily steps and minutes spent in different PA intensities. METHODS: Twenty-four young PWH wore a wrist-worn Fitbit Charge 3 and hip-worn ActiGraph GT3X-BT simultaneously for seven consecutive days in free-living conditions. Correlation of and differences between the devices for daily averages of PA parameters were assessed using Pearson's correlation coefficient and paired t-test, respectively. Agreement between devices was assessed using Bland-Altman plots. RESULTS: Twenty participants (mean age 21.8) were included in the analyses. We found moderate to high correlations between Fitbit and ActiGraph measured daily averages for all PA variables, but statistically significant differences between devices for all variables except daily minutes of moderate PA. Fitbit overestimated average daily steps, minutes of light, vigorous and moderate-to-vigorous PA. Bland-Altman plots showed a measurement bias between devices for all parameters with increasing overestimation by the Fitbit for higher volumes of PA. CONCLUSION: The Fitbit Charge 3 overestimated steps and minutes of light, moderate and moderate-to-vigorous PA as compared to the ActiGraph GT3X-BT, and this bias increased with PA volume. The Fitbit should therefore be used with caution in research, and we advise users of the device to be cognizant of this overestimation.


Subject(s)
Fitness Trackers , Hemophilia A , Humans , Adolescent , Young Adult , Adult , Accelerometry , Reproducibility of Results , Exercise
17.
J Child Psychol Psychiatry ; 63(3): 282-295, 2022 03.
Article in English | MEDLINE | ID: mdl-34184767

ABSTRACT

BACKGROUND: Adolescence is characterized by alterations in biobehavioral functioning, during which individuals are at heightened risk for onset of psychopathology, particularly internalizing disorders. Researchers have proposed using digital technologies to index daily biobehavioral functioning, yet there is a dearth of research examining how wearable metrics are associated with mental health. METHODS: We preregistered analyses using the Adolescent Brain Cognitive Development Study dataset using wearable data collection in 5,686 adolescents (123,862 person-days or 2,972,688 person-hours) to determine whether wearable indices of resting heart rate (RHR), step count, and sleep duration and variability in these measures were cross-sectionally associated with internalizing symptomatology. All models were also run controlling for age, sex, body mass index, socioeconomic status, and race. We then performed prospective analyses on a subset of this sample (n = 143) across 25 months that had Fitbit data available at baseline and follow-up in order to explore directionality of effects. RESULTS: Cross-sectional analyses revealed a small, yet significant, effect size (R2 = .053) that higher RHR, lower step count and step count variability, and greater variability in sleep duration were associated with greater internalizing symptoms. Cross-lagged panel model analysis revealed that there were no prospective associations between wearable variables and internalizing symptoms (partial R2 = .026), but greater internalizing symptoms and higher RHR predicted lower step count 25 months later (partial R2 = .010), while higher RHR also predicted lower step count variability 25 months later (partial R2 = .008). CONCLUSIONS: Findings indicate that wearable indices concurrently associate with internalizing symptoms during early adolescence, while a larger sample size is likely required to accurately assess prospective or directional effects between wearable indices and mental health. Future research should capitalize on the temporal resolution provided by wearable devices to determine the intensive longitudinal relations between biobehavioral risk factors and acute changes in mental health.


Subject(s)
Wearable Electronic Devices , Adolescent , Arousal , Body Mass Index , Cross-Sectional Studies , Humans , Psychopathology
18.
J Sex Med ; 19(9): 1387-1396, 2022 09.
Article in English | MEDLINE | ID: mdl-35909074

ABSTRACT

BACKGROUND: Many studies have reported a possible strong relationship between poor sleep quality, sleep disruption, sleep disorders, and erectile dysfunction (ED). AIM: This study aimed to investigate the relationship between sleep quality and ED. METHODS: Patients diagnosed with ED by the International Index of Erectile Function-5 (IIEF-5) questionnaire and 72 healthy adult men were included. Participants completed the questionnaire, underwent a detailed physical examination, and provided blood samples. All enrolled subjects then wore the Fitbit Charge 2 that monitored sleep throughout the night. OUTCOMES: Primary outcome measures included scores on the IIEF-5, General Anxiety Disorder-7 (GAD-7) scale, Patient Health Questionnaire-9 (PHQ-9), Pittsburgh Sleep Quality Index (PSQI), and sleep monitoring parameters obtained from Fitbit Charge 2. RESULTS: Finally, a total of 107 ED patients and 72 healthy adult men were enrolled in this study. Univariate analysis indicated that the GAD-7 (P < .001), PHQ-9 (P < .001), and PSQI scores (P < .001) significantly differed according to the presence/absence of ED. Further multiple logistic regression analysis showed that the PHQ-9 (odds ratio [OR]: 1.227, 95% confidence interval [CI]: 1.070-1.407; P = .003) and PSQI scores (OR: 1.220, 95%CI: 1.116-1.334; P < .001) were independent risk factors for ED. Analysis of objective sleep monitoring parameters showed that total sleep time (TST) (P = .001), sleep onset latency (SOL) (P = .026), deep sleep (N3) duration (P = .011) and rapid eye movement (REM) sleep duration (P < .001) were significantly differed between the 2 groups, with durations in the ED group significantly lower than those in the non-ED group. In addition, receiver operating characteristic (ROC) curve analysis indicated that the REM sleep duration had the highest area under the curve (AUC: 0.728) of all sleep parameters, with a P value < .001, a sensitivity of 72.2% and a specificity of 73.8%. CLINICAL IMPLICATIONS: Urologists and andrologists should be aware of impacted sleep quality and depression in ED patients. STRENGTHS & LIMITATIONS: The strength of this study is that the relationship between sleep quality and ED was assessed with both a subjective scale and an objective sleep monitoring tool. However, our study only described an association between sleep quality and ED and did not establish a causal relationship. CONCLUSION: Sleep parameters are strongly associated with ED, indicating that poor sleep quality may increase the likelihood of ED. Wu X, Zhang Y, Zhang W, et al. The Association Between Erectile Dysfunction and Sleep Parameters: Data from a Prospective, Controlled Cohort. J Sex Med 2022;19:1387-1396.


Subject(s)
Erectile Dysfunction , Adult , Cohort Studies , Humans , Male , Prospective Studies , Risk Factors , Sleep
19.
Curr Cardiol Rep ; 24(8): 995-1009, 2022 08.
Article in English | MEDLINE | ID: mdl-35635678

ABSTRACT

PURPOSE OF REVIEW: Wearable technology is rapidly evolving and the data that it can provide regarding an individual's health is becoming increasingly important for clinicians to consider. The purpose of this review is to help inform health care providers of the benefits of smartwatch interrogation, with a focus on reviewing the various parameters and how to apply the data in a meaningful way. RECENT FINDINGS: This review details interpretation of various parameters found commonly in newer smartwatches such as heart rate, step count, ECG, heart rate recovery (HRR), and heart rate variability (HRV), while also discussing potential pitfalls that a clinician should be aware of. Smartwatch interrogation is becoming increasingly relevant as the continuous data it provides helps health care providers make more informed decisions regarding diagnosis and treatment. For this reason, we recommend health care providers familiarize themselves with the technology and integrate it into clinical practice.


Subject(s)
Wearable Electronic Devices , Electrocardiography/instrumentation , Electrocardiography/methods , Exercise Test/instrumentation , Exercise Test/methods , Heart Rate/physiology , Humans
20.
J Med Internet Res ; 24(12): e42359, 2022 12 30.
Article in English | MEDLINE | ID: mdl-36583938

ABSTRACT

BACKGROUND: Over the recent years, technological advances of wrist-worn fitness trackers heralded a new era in the continuous monitoring of vital signs. So far, these devices have primarily been used for sports. OBJECTIVE: However, for using these technologies in health care, further validations of the measurement accuracy in hospitalized patients are essential but lacking to date. METHODS: We conducted a prospective validation study with 201 patients after moderate to major surgery in a controlled setting to benchmark the accuracy of heart rate measurements in 4 consumer-grade fitness trackers (Apple Watch 7, Garmin Fenix 6 Pro, Withings ScanWatch, and Fitbit Sense) against the clinical gold standard (electrocardiography). RESULTS: All devices exhibited high correlation (r≥0.95; P<.001) and concordance (rc≥0.94) coefficients, with a relative error as low as mean absolute percentage error <5% based on 1630 valid measurements. We identified confounders significantly biasing the measurement accuracy, although not at clinically relevant levels (mean absolute error<5 beats per minute). CONCLUSIONS: Consumer-grade fitness trackers appear promising in hospitalized patients for monitoring heart rate. TRIAL REGISTRATION: ClinicalTrials.gov NCT05418881; https://www.clinicaltrials.gov/ct2/show/NCT05418881.


Subject(s)
Electrocardiography , Fitness Trackers , Humans , Heart Rate/physiology , Monitoring, Physiologic , Patients , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL