Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 269
Filter
Add more filters

Publication year range
1.
Arch Orthop Trauma Surg ; 144(8): 3369-3378, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39126454

ABSTRACT

INTRODUCTION: Cementless fixation has become increasingly popular in hip arthroplasty due to its shorter operation time, easier technique, biologic fixation, and avoidance of bone cement implantation syndrome compared to cemented fixation. However, intraoperative periprosthetic femoral fracture (IOPFx) is a disconcerting complication during cementless hip arthroplasty. Our purpose was to identify the features of cementless stem that increase the risk of IOPFx during primary hip arthroplasty. MATERIALS AND METHODS: We retrospectively reviewed all 4806 hip arthroplasties that was performed in a single institution from May 2003 to December 2020. Age at the index arthroplasty, sex, body mass index, physical status, ambulatory function, side of the operation, operational history, cause of the index arthroplasty, type of arthroplasty, surgical approach, surgeon, implant information, and events during the operation were investigated. The shoulder geometry and length of stem were also reviewed. The event of interest was narrowed down to IOPFx among various records of intraoperative events. RESULTS: We found IOPFx of 2.6% among all the hips operated with cementless stem. In the multivariable analysis, female (OR = 1.52), childhood hip disease (OR = 2.30), stove-pipe femur (OR = 2.43), combined approach (OR = 2.60), and standard length of stem (OR = 1.59) were found to be significant risk factors of IOPFx. CONCLUSIONS: In conclusion, a stem with a standard length is significantly associated with risk of IOPFx compared to a shortened stem. These findings highlight the importance of careful consideration in terms of the risk of IOPFx when standard length cementless stem is chosen.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Fractures , Hip Prosthesis , Humans , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/instrumentation , Female , Male , Retrospective Studies , Middle Aged , Hip Prosthesis/adverse effects , Aged , Femoral Fractures/surgery , Femoral Fractures/etiology , Risk Factors , Intraoperative Complications/etiology , Periprosthetic Fractures/etiology , Prosthesis Design , Adult , Aged, 80 and over
2.
Beijing Da Xue Xue Bao Yi Xue Ban ; 56(1): 81-87, 2024 Feb 18.
Article in Zh | MEDLINE | ID: mdl-38318900

ABSTRACT

OBJECTIVE: To compare the trueness of incisal guidance of implant-supported single crowns designed by patient-specific motion (PSM) with that designed by average-value virtual articulator (AVA). METHODS: The study had recruited 12 participants with complete dentition and stable incisal guidance. An intraoral scanner was used to scan digital casts and record two types of patient-specific motion (data only including protrusive movement, and data including protrusive movement and lateral protrusive movement). The lingual surfaces of the maxillary incisors which guided the protrusive movement was selected and elevated to create a reference cast. A maxillary central incisor of original casts was vir-tually extracted and implanted to generate a working cast. The Dental system software program was used to design implant-supported single crowns with the anatomical coping design method. The incisal guidance was designed by different methods. The incisal guidance in control group was designed by the average-value virtual articulator. The incisal guidance in experiment groups was designed by the patient-specific motion only including protrusive movement (PSM1) and with the patient-specific motion including protrusive movement and lateral protrusive movement (PSM2). The incisal guidance of prosthesis designed by these 3 methods were compared with the original incisal guidance in Geomagic Control 2015 (3DSystem, America). The measurements included: Average of positive values, ratio of positive area and maximum value reflecting supra-occlusion; average of negative values, ratio of negative area and minimum value reflecting over-correction; and root mean square reflecting overall deviation. RESULTS: Statistical data were collected using the median (interquartile range) method. The average of positive values, ratio of positive area and average of negative values of the PSM2 group were smaller than those of the control group [8.0 (18.8) µm vs. 37.5 (47.5) µm; 0 vs. 7.2% (38.1%); -109.0 (63.8) µm vs.-66.5 (64.5) µm], and the ratio of negative area of PSM2 group was larger than those of the control group [52.9% (47.8%) vs. 17.3% (45.3%)], with significant differences (P all < 0.05). The ratio of positive area [0.1% (7.0%)] and average of negative values [-97.0 (61.5) µm] of PSM1 group, were smaller than those of the control group, and the ratio of negative area [40.7% (39.2%)] of the PSM1 group was larger than that of the control group, with significant differences (P < 0.05). The average of positive values [20.0 (42.0) µm] and ratio of positive area of PSM1 group was larger than that of the PSM2 group with significant differences (P < 0.05). CONCLUSION: To establish the incisor guidance of implant-supported single crowns, compared with the average-value virtual articulator and the patient-specific motion only including protrusive movement, the patient-specific motion including protrusive movement and lateral protrusive movement is more conducive to reducing the protrusive interference of prosthesis and improving the occlusal fit.


Subject(s)
Incisor , Software , Humans , Maxilla , Crowns , Movement , Computer-Aided Design
3.
J Prosthodont ; 33(7): 655-662, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38487989

ABSTRACT

PURPOSE: The objective of this retrospective study was to evaluate the effect of the interproximal contour of single external hexagon implant restorations on the prevalence of peri-implantitis. MATERIAL AND METHODS: Records of 96 patients and 148 external hexagon (EH) implants with time in function ranging from 1 to 17 years were included in the study. The most recent clinical and radiographic data were collected from records and the prevalence of peri-implantitis was defined according to the 2017 World Workshop on the Classification of Periodontal and Peri-implant Diseases and Conditions. Marginal bone level (MBL), emergence angle (EA), emergence profile (EP), and crown/implant platform horizontal ratio (CIHR) were obtained from periapical radiographs. Dichotomous variables at the patient- and implant level were compared with association tests. Mann-Whitney U-Test was performed to compare continuous quantitative values between the studied groups. Binomial logistic regression was conducted to identify risk indicators associated with the peri-implantitis event at the patient- and implant level, with the significance level set at 5% for all tests. RESULTS: Nineteen patients (19.2%) and 24 implants (16.2%) with a mean time in function of 5.0 ± 4.7 years were classified as having peri-implantitis. No statistically significant differences concerning gender, mean age, implant location in the jaw, or time in function were observed between patients with or without peri-implantitis (p > 0.05). Of 24 implants with peri-implantitis 10 (41.7%) displayed EA ≤ 30° (16.4%) while 14 (58.3%) presented EA > 30° with no statistical difference between the groups (p > 0.05). No statistically significant associations were identified between EA, EP, or CIHR and the prevalence of peri-implantitis. CONCLUSION: The findings seem to indicate that the EA, EP, and CIHR of single restorations over external hexagon implants are not associated with the presence of peri-implantitis. However, prospective studies with larger samples are required to better ascertain such an association in the long term.


Subject(s)
Peri-Implantitis , Humans , Peri-Implantitis/etiology , Peri-Implantitis/epidemiology , Retrospective Studies , Male , Female , Middle Aged , Prevalence , Adult , Aged , Dental Prosthesis Design
4.
J Prosthodont ; 33(3): 231-238, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37218377

ABSTRACT

PURPOSE: Digital technologies are continuously improving the accuracy and quality of maxillofacial prosthetics, but their impact on patients remains unclear. This cross-sectional study aimed to analyze the impact of facial prosthetics service provision, patients' perception, and digital technology on prostheses construction. MATERIALS AND METHODS: All patients who presented for evaluation and management of facial defects between January 2021 and December 2021 at the ENT clinic were eligible for study enrollment. Patients requiring prosthetic reconstruction of their missing facial parts were included in the study. Forty-five questionnaires were delivered, inquiring about the patients' prosthetic demographics, prosthesis manufacture using 3D technologies, and their perceptions and attitudes. RESULTS: A total of 37 patients responded (29 males, eight females; mean age 20.50 years). The congenital cause was the highest among other causes (p = 0.001) with auricular defects being the highest (p = 0.001). A total of 38 prostheses were constructed and 17 prostheses were retained by 36 craniofacial implants (p = 0.014). The auricular and orbital implants success rates were 97% and 25%, respectively. The implant locations were digitally planned pre-operatively. Digital 3D technologies of defect capture, data designing, and 3D modeling were used and perceived as helpful and comfortable (p = 0.001). Patients perceived their prosthesis as easy to handle, suited them, and they felt confident with it (p = 0.001). They wore it for more than 12 h daily (p = 0.001). They were not worried that it would be noticed, and found it comfortable and stable during various activities (p = 0.001). Implant-retained prosthesis patients were more satisfied with it, and found it easy to handle and stable (p = 0.001). CONCLUSIONS: Congenital defects are the main cause of facial defects in the study country. The overall acceptance of maxillofacial prostheses was good, showing high patient perception and satisfaction. Ocular and implant-retained silicone prostheses are better handled, more stable, and the latter is more satisfying than traditional adhesive prostheses. Digital technologies save time and effort invested in manufacturing facial prostheses.


Subject(s)
Dental Implants , Digital Technology , Male , Female , Humans , Young Adult , Adult , Prosthesis Design , Cross-Sectional Studies , Delivery of Health Care , Prostheses and Implants
5.
J Prosthodont ; 2024 May 12.
Article in English | MEDLINE | ID: mdl-38734932

ABSTRACT

PURPOSE: To evaluate the fracture resistance of zirconia overlays, considering various preparation designs and the presence of endodontic access. MATERIALS AND METHODS: Ninety translucent zirconia (5Y-PSZ) overlay restorations were divided into six groups (n = 15/group) based on different preparation designs, with and without endodontic access: chamfer margin 4 mm above the gingival level without (group 1) and with endodontic access (group 2); margin 2 mm above the gingival level without (group 3) and with endodontic access (group 4); overlay with no chamfer margin without (group 5) and with endodontic access (group 6). Restorations were bonded to mandibular first molar resin dies, and the groups with endodontic access were sealed with flowable resin composite. All restorations underwent 100,000 cycles of thermal cycling between 5°C and 55°C, followed by loading until fracture. Maximum load and fracture resistance were recorded. ANOVA with Tukey post-hoc tests were used for statistical comparison (α < 0.05). RESULTS: Fracture resistance significantly varied among overlay designs with and without endodontic access (p < 0.001), except for the no-margin overlays (groups 5 and 6). Overlays with a 2 mm margin above the gingival margin with endodontic access (group 4) exhibited significantly higher fracture resistance compared to both the 4-mm supragingival (group 2) and no-margin (group 6) designs, even when compared to their respective intact groups (groups 1 and 5). There were no significant differences between the no-margin and 4-mm supragingival overlays. CONCLUSION: The more extensive zirconia overlay for mandibular molars is the first choice since the 2 mm margin above the gingival level design withstood considerable loads even after undergoing endodontic access. A no-margin overlay is preferred over the 4-mm supragingival design as it preserves more tooth structure and there was no outcome difference, irrespective of endodontic access. Caution is warranted in interpreting these findings due to the in vitro nature of the study.

6.
Medicina (Kaunas) ; 60(5)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38792903

ABSTRACT

(1) Background: Recent digital workflows are being developed for full-arch rehabilitations supported by implants with immediate function. The purpose of this case series is to describe a new digital workflow for the All-on-4 concept. (2) Methods: The patients were rehabilitated using the All-on-4 concept with a digital workflow including computerized tomography scanning, intra-oral scanning, and CAD-CAM production of the temporary prosthesis, with the 3D printing of stackable guides (base guide, implant guide, and prosthetic guide). The passive fit of the prostheses and the time to perform the rehabilitations were evaluated. (3) Results: The digital workflow allowed for predictable bone reduction, the insertion of implants with immediate function, and the connection of an implant-supported prosthesis with immediate loading. The time registered to perform the full-arch rehabilitations (implant insertion, abutment connection, prosthesis connection) was below 2 hours and 30 min. No passive fit issues were noted. (4) Conclusions: within the limitation of this case series, the digital workflow applied to the All-on-4 concept using stackable base-, implant-, and prosthetic guides constitutes a potential alternative with decreased time for the procedure without prejudice of the outcome.


Subject(s)
Workflow , Humans , Female , Male , Middle Aged , Computer-Aided Design , Aged , Dental Prosthesis, Implant-Supported/methods , Printing, Three-Dimensional , Tomography, X-Ray Computed/methods , Mouth, Edentulous/rehabilitation
7.
J Contemp Dent Pract ; 25(1): 79-84, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38514436

ABSTRACT

AIM: This study aimed to investigate the effect of modified framework (MF) design on the fracture resistance of IPS e.max Press anterior single crown after thermocycling and cyclic loading. MATERIALS AND METHODS: Two types of IPS e.max Press frameworks were designed (n = 10); standard framework (SF) with a 0.5 mm uniform thickness and MF with a lingual margin of 1 mm in thickness and 2 mm in height connected to a proximal strut of 4 mm height and a 0.3 mm wide facial collar. The crowns were cemented to resin dies, subjected to 5,000 cycles of thermocycling, and loaded 10,000 cycles at 100 N. A universal testing machine was used to load specimens to fracture, and the modes of failure were determined. RESULTS: The mean and standard deviation (SD) of fracture resistance were 219.24 ± 110.00 N and 216.54 ±120.02 N in the SF and MF groups. Thus, there was no significant difference (p = 0.96). Mixed fracture was the most common failure mode in both groups. We found no statistically significant difference between the groups (p = 0.58). CONCLUSION: The MF design did not increase the fracture resistance of IPS e.max Press crown. CLINICAL SIGNIFICANCE: Framework design is an essential factor for the success of all-ceramic restorations and its modification might be regarded as an approach to increase fracture resistance. Furthermore, the modified design was evaluated in metal-ceramic or zirconia crowns while less attention was paid to the IPS e.max Press crowns. How to cite this article: Golrezaei M, Mahgoli HA, Yaghoobi N, et al. The Effect of Modified Framework Design on the Fracture Resistance of IPS e.max Press Crown after Thermocycling and Cyclic Loading. J Contemp Dent Pract 2024;25(1):79-84.


Subject(s)
Dental Porcelain , Dental Restoration Failure , Crowns , Ceramics , Materials Testing , Dental Stress Analysis , Computer-Aided Design , Dental Prosthesis Design
8.
Clin Oral Implants Res ; 34(1): 33-41, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36278423

ABSTRACT

OBJECTIVES: To evaluate the association between different vertical levels of the abutment margin and residual cement prevalence in cement-retained implant restorations with customized abutments. METHODS: One hundred and nine single-unit cement-retained implant restorations with a screw-access channel were included. The crowns were intraorally cemented on the abutments, and excess cement was removed. The abutment-crown complex was unscrewed, and the abutment-crown complex and peri-implant tissue were photographed. Residual cement presence was recorded by dividing the abutment-crown complex and peri-implant tissue into four quadrants: mesial, distal, buccal, and lingual. The prevalence of residual cement was compared according to the height of the custom abutment margin of the corresponding quadrant. A multilevel model was used for statistical analysis (α = .05). RESULTS: Cement remnants were discovered on 72.48% of the dental implants. When the restoration quadrants were compared, cement remnants were present on 51.38%, 39.45%, 20.18%, and 17.43% of the mesial, distal, buccal, and lingual surfaces, respectively (p < .01). Regarding the abutment margin level, cement residues were found in 60.22% and 61.4% of the 0.5 mm subgingival and ≥1 mm subgingival margin groups, respectively, which were significantly more than those in the supragingival (23.65%) and equigingival (26.59%) margin groups (p < .01). After adjustment for confounding factors, the adjusted odds ratio (with 95% confidence interval) for residual cement in the subgingival margin groups was 3.664 (1.71, 7.852) when compared to the supragingival and equigingival margin groups. CONCLUSIONS: The risk of residual cement occurrence was 3.66-fold higher with a subgingival abutment margin than with supragingival and equigingival abutment margins.


Subject(s)
Cementation , Dental Implants , Dental Abutments , Dental Prosthesis, Implant-Supported , Dental Cements , Glass Ionomer Cements/chemistry , Crowns
9.
BMC Geriatr ; 23(1): 632, 2023 10 06.
Article in English | MEDLINE | ID: mdl-37803256

ABSTRACT

OBJECTIVE: This study aimed to measure the parameters of the proximal femur in the older people of Inner Mongolia, China and understand the influence of age and gender so as to provide guidance for the design and improvement of prosthesis for total hip arthroplasty. METHODS: A total of 236 patients who underwent CT angiography of lower limbs in the Department of Imaging, Affiliated Hospital of Inner Mongolia Medical University of China were collected. They were divided into 4 groups according to age: < 60 (group A), 60-69 (group B), 70-79 (group C), and > 80 years (group D). Four anatomical parameters, including femoral head diameter (FHD), femoral neck-shaft angle (FNSA), femoral offset (FO), femoral neck anteversion (FNA), were measured by Mimics 21.0. Comparisons were made between age groups of the same gender and between genders in the same age group to analyze the correlation of the 4 parameters of proximal femur with age and gender. In addition, the results of this study were compared with previous studies. RESULTS: There were no significant differences in FHD and FO between age groups, indicating no correlation with age. FNSA and FNA were no significantly different between group C and group D in the same gender, whereas there were significant differences between other age groups and were negatively correlated with age. There were significant differences in FHD and FO between genders in the same age group, with the males being larger than the females. FNSA and FNA were no significant differences between genders in the same age group. CONCLUSIONS: FNSA and FNA decrease with age. FHD and FO were larger in males than in females in all age groups. Age and gender should be considered in the design of prosthesis.


Subject(s)
Clinical Relevance , Hip Joint , Humans , Female , Male , Aged , Femur/diagnostic imaging , Lower Extremity , China/epidemiology
10.
BMC Musculoskelet Disord ; 24(1): 171, 2023 Mar 07.
Article in English | MEDLINE | ID: mdl-36882825

ABSTRACT

BACKGROUND: Elliptical shape humeral head prostheses have been recently proposed to reflect a more anatomic shoulder replacement. However, its effect on obligate glenohumeral translation during axial rotation compared to a standard spherical head is still not well understood. The purpose of the study was to compare obligate humeral translation during axial rotation using spherical and elliptical shaped humeral head prostheses. It was hypothesized that the spherical head design would show significantly more obligate translation when compared to the elliptical design. METHODS: Six fresh-frozen cadaveric shoulders were utilized for biomechanical testing of internal (IR) and external (ER) rotation at various levels of abduction (0°, 30°, 45°, 60°) with lines of pull along each of the rotator cuff muscles. Each specimen underwent the following three conditions: (1) native; total shoulder arthroplasty (TSA) using (2) an elliptical and (3) spherical humeral head implant. Obligate translation during IR and ER was quantified using a 3-dimensional digitizer. The radius of curvature of the superoinferior and anteroposterior dimensions of the implants was calculated across each condition. RESULTS: Posterior and inferior translation as well as compound motion of spherical and elliptical heads during ER was similar at all abduction angles (P > 0.05, respectively). Compared to the native humeral head, both implants demonstrated significantly decreased posterior translation at 45° (elliptical: P = 0.003; spherical: P = 0.004) and 60° of abduction (elliptical: P < 0.001; spherical: P < 0.001). During internal rotation at 0° abduction, the spherical head showed significantly more compound motion (P = 0.042) compared to the elliptical head. The spherical implant also demonstrated increased anterior translation and compound motion during internal rotation at 60° abduction (P < 0.001) compared to the resting state. This difference was not significant for the native or elliptical head design at this angle (P > 0.05). CONCLUSION: In the setting of TSA, elliptical and spherical head implants showed similar obligate translation and overall compound motion during axial rotation. A gained understanding of the consequences of implant head shape in TSA may guide future surgical implant choice for better recreation of native shoulder kinematics and potentially improved patient outcomes. LEVEL OF EVIDENCE: Controlled Laboratory Study.


Subject(s)
Arthroplasty, Replacement, Shoulder , Arthroplasty, Replacement , Bursitis , Humans , Rotation , Upper Extremity , Humeral Head/surgery
11.
J Neuroeng Rehabil ; 20(1): 147, 2023 11 06.
Article in English | MEDLINE | ID: mdl-37926807

ABSTRACT

BACKGROUND: The prosthetic socket is a key component that influences prosthesis satisfaction, with a poorly fitting prosthetic socket linked to prosthesis abandonment and reduced community participation. This paper reviews adjustable socket designs, as they have the potential to improve prosthetic fit and comfort through accommodating residual limb volume fluctuations and alleviating undue socket pressure. METHODS: Systematic literature and patent searches were conducted across multiple databases to identify articles and patents that discussed adjustable prosthetic sockets. The patents were used to find companies, organisations, and institutions who currently sell adjustable sockets or who are developing devices. RESULTS: 50 literature articles and 63 patents were identified for inclusion, representing 35 different designs used in literature and 16 commercially available products. Adjustable sockets are becoming more prevalent with 73% of publications (literature, patents, and news) occurring within the last ten years. Two key design characteristics were identified: principle of adjustability (inflatable bladders, moveable panels, circumferential adjustment, variable length), and surface form (conformable, rigid multi-DOF, and rigid single DOF). Inflatable bladders contributed to 40% of literature used designs with only one identified commercially available design (n = 16) using this approach. Whereas circumferential adjustment designs covered 75% of identified industry designs compared to only 36% of literature devices. Clinical studies were generally small in size and only 17.6% of them assessed a commercially available socket. DISCUSSION: There are clear differences in the design focus taken by industry and researchers, with justification for choice of design and range of adjustment often being unclear. Whilst comfort is often reported as improved with an adjustable socket, the rationale behind this is not often discussed, and small study sizes reduce the outcome viability. Many adjustable sockets lack appropriate safety features to limit over or under tightening, which may present a risk of tissue damage or provide inadequate coupling, affecting function and satisfaction. Furthermore, the relationship between design and comfort or function are rarely investigated and remain a significant gap in the literature. Finally, this review highlights the need for improved collaboration between academia and industry, with a strong disconnect observed between commercial devices and published research studies.


Subject(s)
Artificial Limbs , Research Design , Humans , Prosthesis Design , Amputation Stumps , Extremities
12.
Knee Surg Sports Traumatol Arthrosc ; 31(8): 3116-3123, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36456826

ABSTRACT

PURPOSE: In up to a fifth of total knee replacements (TKR), surgeons are not capable of achieving good clinical and functional results. Despite comprehensive diagnostic workup, an underlying cause is not always identified in these patients. The purpose of this study is to compare native and prosthetic trochlear anatomies, to evaluate a potential source of morphologic mismatch and theoretically, of poor clinical outcomes. METHODS: Native trochlear angles of 4116 knee CTs from 360 Knee Systems database of arthritic pre-operative TKR patients were evaluated. A semi-automated tridimensional analysis was performed to define the native trochlear angle in the coronal plane (NTA) among other 142 parameters. An active search was conducted to identify currently available TKR models; prosthetic trochlear orientation in the coronal plane (PTA) was extracted from the technical data provided by manufacturers. RESULTS: The mean native trochlear angle (NTA) was 1.6° ± 6.6° (valgus) with a range from - 23.8° (varus) to 30.3°(valgus). A valgus NTA was present in 60.6% of the knees and 39.4% of them had a varus NTA. 89 TKR models were identified; trochlear details were available for 45 of them, of which 93% were designed with a valgus orientation of the prosthetic trochlear angle (PTA) and 6.9% showed a neutral (0°) PTA. Varus alignment of PTA was not present in any system. Angular numeric values for PTA were available for 34 models; these ranged from 0° to 15° of valgus, with a median value of 6.18° (SD ± 2.88°). CONCLUSION: This study shows a significant mismatch between native and prosthetic trochlear angles. A relevant proportion of the studied knees (41.45%) fall out of the trochlear angle range of currently available implants; representing a potential source for biomechanical imbalance. While further research is warranted to fully understand the clinical implications of the present study, manufacturers may need to take these findings into account for future implant designs. LEVEL OF EVIDENCE: Level III, retrospective cohort study.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Retrospective Studies , Knee Joint/diagnostic imaging , Knee Joint/surgery , Knee/surgery , Arthroplasty, Replacement, Knee/methods , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery
13.
Clin Oral Investig ; 27(12): 7261-7271, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37910236

ABSTRACT

OBJECTIVE: The present retrospective study aimed to investigate the influence of malposition on the occurrence of peri-implantitis. MATERIALS AND METHODS: The study included clinical records of systemically healthy patients with single and partial implant-supported rehabilitations and at least 1-year post-loading follow-up. The parameters collected included implant-related factors, patient-related factors, site-related factors, and prosthesis-related factors. The radiographic measurements were taken by using a dedicated software and the diagnosis of peri-implantitis was made based on all the available clinical and radiographic data. Descriptive statistics were provided for all variables. Following an exploratory approach, an implant-level analysis of factors influencing the occurrence of peri-implantitis was done through a multilevel multivariate logistic regression (mixed). RESULTS: A total of 180 implants belonging to 90 subjects were randomly selected. Malposition showed no statistically significant association with the occurrence of peri-implantitis. According to the multi-level analysis, the parameters that were significantly associated with peri-implantitis included presence / history of periodontitis (OR = 5.945, 95% CI: 1.093 - 32.334, P = 0.039) and presence of an emergence profile angle ≥ 45° (OR = 9.094, 95% CI: 2.017 - 40.995, P = 0.005). CONCLUSIONS: Implant malposition, as defined following Buser's criteria (2004), did not influence the occurrence of peri-implantitis in the selected cohort. Conversely, history of periodontitis and presence of a prosthetic emergence profile with an angle ≥ 45° were correlated to an increased risk of peri-implantitis.


Subject(s)
Dental Implants , Peri-Implantitis , Periodontitis , Humans , Peri-Implantitis/diagnostic imaging , Peri-Implantitis/epidemiology , Peri-Implantitis/etiology , Retrospective Studies , Dental Implants/adverse effects , Periodontitis/complications , Radiography
14.
Aesthetic Plast Surg ; 2023 Nov 08.
Article in English | MEDLINE | ID: mdl-37940704

ABSTRACT

BACKGROUND: Paranasal augmentation has been a popular approach in restoring Asian patients' lateral profile. Irregular surface in the surgical area emphasizes the importance of morphological evidence for the preoperative evaluation and the design of paranasal implants. METHODS: We retrospectively collected craniofacial computer tomography scans of patients in the department of plastic surgery from 2020 to 2022. The imaging data were imported to Mimics (version 20.0; Materialize, Leuven, Belgium) for three-dimensional reconstruction. Measurements of osteal nasal base were performed in 3-matics (version 12.0; Materialize). The severity of paranasal concavity was graded by a senior doctor to study the correlation with measured variables. RESULTS: Fifty-seven patients with a median age of 27 years (IQR: 22-33) were included in the study. For design of paranasal implants, the lengths of both lower and lateral edge were measured for reference. In the regression analysis, the alar base-alveolar process angle was significantly associated with the degrees of paranasal concavity (OR = 1.222, p = 0.00001). CONCLUSIONS: Morphological data of osteal nasal base were measured and presented in the current study. The analysis supported that alar base-alveolar process angle be used for preoperative grading and evaluation to help guiding treatment decisions. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

15.
Arch Orthop Trauma Surg ; 143(1): 177-187, 2023 Jan.
Article in English | MEDLINE | ID: mdl-34216260

ABSTRACT

INTRODUCTION: Elliptical-shaped humeral head prostheses have recently been proposed to reflect a more anatomic shoulder replacement. However, its subsequent effect on micro-motion of the glenoid component is still not understood. MATERIALS AND METHODS: Six fresh-frozen, cadaveric shoulders (mean age: 62.7 ± 9.2 years) were used for the study. Each specimen underwent total shoulder arthroplasty using an anatomic stemless implant. At 15°, 30°, 45° and 60° of glenohumeral abduction, 50° of internal and external rotations in the axial plane were alternatingly applied to the humerus with both an elliptical and spherical humeral head design. Glenohumeral translation was assessed by means of a 3-dimensional digitizer. Micro-motion of the glenoid component was evaluated using four high-resolution differential variable reluctance transducer strain gauges, placed at the anterior, posterior, superior, and inferior aspect of the glenoid component. RESULTS: The elliptical head design showed significantly more micro-motion in total and at the superior aspect of glenoid component during external rotation at 15° (total: P = 0.004; superior: P = 0.004) and 30° (total: P = 0.045; superior: P = 0.033) of abduction when compared to the spherical design. However, during internal rotation, elliptical and spherical heads showed similar amounts of micro-motion at the glenoid component at all tested abduction angles. When looking at glenohumeral translation, elliptical and spherical heads showed similar anteroposterior and superoinferior translation as well as compound motion during external rotation at all tested abduction angles. During internal rotation, the elliptical design resulted in significantly more anteroposterior translation and compound motion at all abduction angles when compared to the spherical design (P < 0.05). CONCLUSION: In the setting of total shoulder arthroplasty, the elliptical head design demonstrated greater glenohumeral translation and micro-motion at the glenoid component during axial rotation when compared to the spherical design, potentially increasing the risk for glenoid loosening in the long term. LEVEL OF EVIDENCE: Controlled Laboratory Study.


Subject(s)
Arthroplasty, Replacement, Shoulder , Shoulder Joint , Humans , Middle Aged , Aged , Shoulder Joint/surgery , Biomechanical Phenomena , Range of Motion, Articular , Cadaver , Humeral Head/surgery
16.
J Prosthodont ; 32(3): 214-220, 2023 Mar.
Article in English | MEDLINE | ID: mdl-35964246

ABSTRACT

PURPOSE: To determine the survival rate, incidence of prosthetic complications, and patient satisfaction of implant fixed complete dental prostheses (IFCDPs) after a mean observation period of 1.4 years. MATERIALS AND METHODS: Twenty-eight (28) eligible participants were recruited according to specific inclusion and exclusion criteria. The definitive metal-acrylic resin IFCDPs consisted of titanium bars veneered with acrylic resin and acrylic denture teeth. Prosthodontic complications, divided into major and minor, were monitored. Parameters such as gender, jaw location, bruxism, and occlusal scheme were evaluated. Moreover, a questionnaire was administered throughout the study to assess patient satisfaction. Poisson regression as well as repeated measures ANOVA were used for statistical analysis. RESULTS: Fourteen (14) males and 14 females were enrolled and followed-up at 3, 6, and 12 months. All IFCDPs survived (100% survival rate). The most frequent minor complication was the loss of material used to close the screw access hole (20% out of total complications). The most frequent major complication was chipping of the acrylic denture teeth (77.14% out of total complications). Gender (p = 0.008) and bruxism (p = 0.030) were significant predictors for the total major complications (major wear and major chipping) while occlusal scheme was a significant predictor for major chipping events (p = 0.030). CONCLUSIONS: While IFCDPs demonstrated high prosthetic survival rates, they also exhibited a high number of chipping events of the acrylic veneering material, especially in males, bruxers, and individuals with canine guidance occlusion. However, the occurrence of these prosthetic complications did not negatively affect patient satisfaction.


Subject(s)
Bruxism , Dental Implants , Male , Female , Humans , Prospective Studies , Survival Rate , Patient Satisfaction , Dental Restoration Failure , Retrospective Studies , Acrylic Resins
17.
Medicina (Kaunas) ; 59(6)2023 May 29.
Article in English | MEDLINE | ID: mdl-37374252

ABSTRACT

Background and Objective: This study aimed to compare the surface finish of milled leucite-reinforced ceramics polished with ceramic and composite polishing systems based on the manufacturers' recommendations. Materials and Methods: Sixty subtractive computer-aided manufactured (s-CAM) leucite-reinforced glass-ceramic specimens (IPS-Empress-CAD) were assigned into six groups: no polishing, a ceramic polishing kit, and four composite kit groups. The roughness average (Ra) was evaluated in microns using a profilometer, and scanning electron micrographs were obtained for qualitative analysis. A Tukey HSD posthoc test (α = 0.05) was used to determine significant intergroup differences. Results: After surface evaluation of the ceramics, the Ra values of the polishing systems ranked OptraFine (0.41 ± 0.26) < Enhance (1.60 ± 0.54) < Shofu (2.14 ± 0.44) < Astropol (4.05 ± 0.72) < DiaComp (5.66 ± 0.62) < No Polishing (5.66 ± 0.74). Discussion: Composite polishing systems did not provide as smooth surfaces as the ceramic polishing kit for CAD-CAM leucite-reinforced ceramics. Thus, using ceramic polishing systems, polishing leucite ceramics is recommended, whereas composite polishing systems should not be considered as an alternative for use in minimally invasive dentistry.


Subject(s)
Ceramics , Composite Resins , Humans , Materials Testing , Surface Properties
18.
Clin Oral Implants Res ; 33 Suppl 23: 137-144, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35763017

ABSTRACT

OBJECTIVES: To systematically assess the literature and report on (1) the frequency of occurrence of buccal soft tissue dehiscence (BSTD) at implants, (2) factors associated with the occurrence of BSTD and (3) treatment outcomes of reconstructive therapy for the coverage of BSTD. MATERIALS AND METHODS: Two systematic reviews addressing focused questions related to implant BSTD occurrence, associated factors and the treatment outcomes of BSTD coverage served as the basis for group discussions and the consensus statements. The main findings of the systematic reviews, consensus statements and implications for clinical practice and for future research were formulated within group 3 and were further discussed and reached final approval within the plenary session. RESULTS: Buccally positioned implants were the factor most strongly associated with the risk of occurrence of BSTD, followed by thin tissue phenotype. At immediate implants, it was identified that the use of a connective tissue graft (CTG) may act as a protective factor for BSTD. Coverage of BSTD may be achieved with a combination of a coronally advanced flap (CAF) and a connective tissue graft, with or without prosthesis modification/removal, although feasibility of the procedure depends upon multiple local and patient-related factors. Soft tissue substitutes showed limited BSTD coverage. CONCLUSION: Correct three-dimensional (3D) positioning of the implant is of utmost relevance to prevent the occurrence of BSTD. If present, BSTD may be covered by CAF +CTG, however the evidence comes from a low number of observational studies. Therefore, future research is needed for the development of further evidence-based clinical recommendations.


Subject(s)
Dental Implants , Plastic Surgery Procedures , Dental Implantation, Endosseous/methods , Dental Implants/adverse effects , Osteology , Surgical Flaps
19.
Clin Oral Implants Res ; 33(3): 313-321, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34971468

ABSTRACT

OBJECTIVES: To compare 2 implant scan bodies with different geometry on the accuracy of the virtual alignment process in the digital workflow. MATERIALS AND METHODS: A master model of the edentulous maxilla with 6 implants and multiunit abutments (MUA) inserted was fabricated. Six dome-shaped and cuboidal scan bodies were mounted on the MUAs, respectively, and consecutively scanned by a laboratory scanner 10 times. The original scans were imported to a dental-specific CAD software and virtually aligned with the default CAD model in the implant library. Thus, 10 aligned models were created. Both the original scans and the aligned models were evaluated by an inspection software for deviation of the scan body surfaces, the centroids of scan body and MUA, the scan body center-axis, and the inter-MUA distances/angles. The two-sample T-test/Mann-Whitney U test were used to analyze the data with the level of significance set at 0.05. RESULTS: The cuboidal group showed significant greater deviations of the model surface (13.9 µm vs. 10.7 µm) and the MUA centroids (31.7 µm vs. 22.8 µm) but smaller deviation of the inter-MUA angle (0.047° vs. 0.070°) than those of the dome-shaped group (p < .05). No significant differences in the deviation of scan body centroids, center-axis, and the inter-MUA distances between the 2 groups were found. CONCLUSIONS: Virtual alignment of implant scan body affected the accuracy of the digital workflow for complete-arch implant-supported prostheses (up to ~30 µm/0.09°). Different geometries of the implant scan body could also influence the transfer accuracy in the CAD process.


Subject(s)
Dental Implants , Computer-Aided Design , Dental Impression Technique , Dental Prosthesis, Implant-Supported , Imaging, Three-Dimensional , Workflow
20.
Ann Vasc Surg ; 81: 60-69, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34788702

ABSTRACT

BACKGROUND: Fenestrated and branched endovascular aortic repair (fEVAR-bEVAR) is a viable treatment option for thoracoabdominal aortic aneurysms but target visceral stent (TVS) endoleak and thrombosis remain a limiting factor. This study aims to evaluate TVS anatomy impact on 1-year risk of thrombosis and endoleak. METHODS: Patients treated with fEVAR-bEVAR for thoracoabdominal aneurysms between 2008 and 2020 in our centre were enrolled. We recorded comorbidities, operative details, 1-month postoperative CT scan (anatomical reference), and TVS behaviour: thrombosis and endoleak at 1-year follow-up. For each TVS, different points were identified using a centre-lumen-line: (A) TVS origin, (B) end of branch/fenestration, (C) visceral vessel entry, (D) end of TVS, (E) 1-cm distally. We analyzed TVS tortuosity ((centre-lumen-line/straight distance)-1, in %), image vector analysis of each segment in 2D (antero-posterior, left-right) and 3D (craneo-caudal displacement), and centre-lumen-line analysis (bending in ABC and CDE). Three independent observers performed a blind analysis, and anatomical differences between bEVAR/fEVAR, and cases with/without 1-year thrombosis and TVS endoleak, were compared using Kaplan-Meier curves (Log-Rank test), and t-test/Wilcoxon signed-ranks test respectively. RESULTS: Fifty-four patients (72 ± 713 years mean age; 182 TVS: 50 branches, 132 fenestrations) met the inclusion criteria. bEVAR cases had longer stents, with more caudal 3D angulation, and greater ABC angulated segment. After excluding bEVAR cases (low case number), 97 fEVAR TVS were analyzed. Five thrombosis and 7 endoleaks were observed. While anatomical configuration showed no association to thrombosis, it was related to endoleak: these cases presented more tortuous stents (5.97% ± 0.10, 21.40% ± 0,22, P = 0.011), with more angulated centre-lumen-line at ABC segment (5.69° ± 15.77°, 7.18° ± 7.77°, P = 0.012), and more upward-pointing stents in the origin of the stent (AB: 89.07° ± 24.46°, 109.09° ± 16.56°, P = 0.012; BC: 87.86° ± 21.10°, 113.11° ± 22.23°, P = 0.026). CONCLUSIONS: Anatomical configuration of the TVS is associated with type III endoleak, but not thrombosis, at 1-year following fEVAR. Cases with endoleak presented more tortuous stents, with a more angulated exit from the endograft, and upward-pointing of the origin of the stent.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/etiology , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Humans , Prosthesis Design , Retrospective Studies , Risk Factors , Stents , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL