1.
Eur Radiol ; 28(1): 143-150, 2018 Jan.
Article in English | MEDLINE | ID: mdl-28695359

ABSTRACT

OBJECTIVE: To assess the performance of hybrid (HIR) and model-based iterative reconstruction (MIR) in patients with urolithiasis at reduced-dose computed tomography (CT). METHODS: Twenty patients scheduled for unenhanced abdominal CT for follow-up of urolithiasis were prospectively included. Routine dose acquisition was followed by three low-dose acquisitions at 40%, 60% and 80% reduced doses. All images were reconstructed with filtered back projection (FBP), HIR and MIR. Urolithiasis detection rates, gall bladder, appendix and rectosigmoid evaluation and overall subjective image quality were evaluated by two observers. RESULTS: 74 stones were present in 17 patients. Half the stones were not detected on FBP at the lowest dose level, but this improved with MIR to a sensitivity of 100%. HIR resulted in a slight decrease in sensitivity at the lowest dose to 72%, but outperformed FBP. Evaluation of other structures with HIR at 40% and with MIR at 60% dose reductions was comparable to FBP at routine dose, but 80% dose reduction resulted in non-evaluable images. CONCLUSIONS: CT radiation dose for urolithiasis detection can be safely reduced by 40 (HIR)-60 (MIR) % without affecting assessment of urolithiasis, possible extra-urinary tract pathology or overall image quality. KEY POINTS: • Iterative reconstruction can be used to substantially lower the radiation dose. • This allows for radiation reduction without affecting sensitivity of stone detection. • Possible extra-urinary tract pathology evaluation is feasible at 40-60% reduced dose.


Subject(s)
Image Processing, Computer-Assisted/methods , Radiation Dosage , Tomography, X-Ray Computed/methods , Urolithiasis/diagnostic imaging , Algorithms , Female , Humans , Male , Middle Aged , Prospective Studies , Radiographic Image Interpretation, Computer-Assisted/methods , Urinary Tract/diagnostic imaging
2.
J Med Radiat Sci ; 67(4): 260-268, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32495517

ABSTRACT

INTRODUCTION: High kVp techniques, 15% or 10-kVp rules, are well-known dose reduction methods. Traditionally, the use of high tube potential (i.e. increased kVp) is associated with decreased radiographic contrast and overall image quality. Recent studies suggest contrast and image quality are not heavily reliant on kVp with digital systems. This study aims to assess the effects of the high tube potential technique on clinical radiographic image quality when using digital systems, to validate high kVp as a dose saving technique. METHODS: A selection of comparable pelvis and lumbar spine radiographs were collected from the hospital's picture archiving and communication system (PACS), with technical factors recorded. All clinical radiographs were assessed by 5 senior radiographers using a 15-point visual grading analysis (VGA) rubric. RESULTS: For 40 AP pelvis radiographs and 40 lateral lumbar spine radiographs, reduction in the dose area product (DAP) with higher kVp is seen. Average pelvis DAP at 75 kVp = 14.06 mGy.cm2 ; 85 kVp = 7.47 mGy.cm2 . Average lumbar spine DAP at 80 kVp = 15.76 mGy.cm2 ; 90 kVp = 14.83 mGy.cm2 . Image quality and contrast scores showed no statistically significant difference between the high and low kVp groups (z = 0.06 and 0.12, respectively). Average pelvis VGA score at 75 kVp = 11.26; 85 kVp = 12.55. Average lumbar spine VGA score at 80 kVp = 9.23; 90 kVp = 10.64. CONCLUSIONS: The high tube potential techniques allowed for reduced patient radiation doses whilst showing no degradation of diagnostic image quality in a clinical setting. This study successfully validates the high kVp technique as a useful tool for reducing patient radiation doses whilst maintaining high diagnostic image quality for digital pelvis and lumbar spine radiography.


Subject(s)
Lumbar Vertebrae/diagnostic imaging , Pelvis/diagnostic imaging , Radiographic Image Enhancement/instrumentation , Humans , Quality Control