Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 130
Filter
Add more filters

Publication year range
1.
Magn Reson Med ; 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38888139

ABSTRACT

PURPOSE: To introduce an alternative idea for fat suppression that is suited both for low-field applications where conventional fat-suppression approaches become ineffective due to narrow spectral separation and for applications with strong B0 homogeneities. METHODS: Separation of fat and water is achieved by sweeping the frequency of RF saturation pulses during continuous radial acquisition and calculating frequency-resolved images using regularized iterative reconstruction. Voxel-wise signal-response curves are extracted that reflect tissue's response to RF saturation at different frequencies and allow the classification into fat or water. This information is then utilized to generate water-only composite images. The principle is demonstrated in free-breathing abdominal and neck examinations using stack-of-stars 3D balanced SSFP (bSSFP) and gradient-recalled echo (GRE) sequences at 0.55 and 3T. Moreover, a potential extension toward quantitative fat/water separation is described. RESULTS: Experiments with a proton density fat fraction (PDFF) phantom validated the reliability of fat/water separation using signal-response curves. As demonstrated for abdominal imaging at 0.55T, the approach resulted in more uniform fat suppression without loss of water signal and in improved CSF-to-fat signal ratio. Moreover, the approach provided consistent fat suppression in 3T neck exams where conventional spectrally-selective fat saturation failed due to strong local B0 inhomogeneities. The feasibility of simultaneous fat/water quantification has been demonstrated in a PDFF phantom. CONCLUSION: The proposed principle achieves reliable fat suppression in low-field applications and adapts to high-field applications with strong B0 inhomogeneity. Moreover, the principle potentially provides a basis for developing an alternative approach for PDFF quantification.

2.
Magn Reson Med ; 2024 Jul 12.
Article in English | MEDLINE | ID: mdl-38997798

ABSTRACT

PURPOSE: Breath-held fat-suppressed volumetric T1-weighted MRI is an important and widely-used technique for evaluating the abdomen. Both fat-saturation and Dixon-based fat-suppression methods are used at conventional field strengths; however, both have challenges at lower field strengths (<1.5T) due to insufficient fat suppression and/or inadequate resolution. Specifically, at lower field strengths, fat saturation often fails due to the short T1 of lipid; and Cartesian Dixon imaging provides poor spatial resolution due to the need for a long ∆TE, due to the smaller ∆f between water and lipid. The purpose of this work is to demonstrate a new approach capable of simultaneously achieving excellent fat suppression and high spatial resolution on a 0.55T whole-body system. METHODS: We applied 3D stack-of-spirals Dixon imaging at 0.55T, with compensation of concomitant field phase during reconstruction. The spiral readouts make efficient use of the requisite ∆TE. We compared this with 3D Cartesian Dixon imaging. Experiments were performed in 2 healthy and 10 elevated liver fat volunteers. RESULTS: Stack-of-spirals Dixon imaging at 0.55T makes excellent use of the required ∆TE, provided high SNR efficiency and finer spatial resolution (1.7 × 1.7 × 5 mm3) compared Cartesian Dixon (3.5 × 3.5 × 5 mm3), within a 17-s breath-hold. We observed successful fat suppression, and improved definition of structures such as the liver, kidneys, and bowel. CONCLUSION: We demonstrate that high-resolution single breath-hold volumetric abdominal T1-weighted imaging is feasible at 0.55T using spiral sampling and concomitant field correction. This is an attractive alternative to existing Cartesian-based methods, as it simultaneously provides high-resolution and excellent fat-suppression.

3.
Eur Radiol ; 2024 Aug 02.
Article in English | MEDLINE | ID: mdl-39093414

ABSTRACT

OBJECTIVE: To investigate the value of fat-suppression (FS) T2 relaxation time (T2RT) derived from FS T2 mapping and water fraction (WF) derived from T2 IDEAL to predict the treatment response to intravenous glucocorticoids (IVGC) in patients with thyroid-associated ophthalmopathy (TAO) based on texture analysis. MATERIALS AND METHODS: In this study, 89 patients clinically diagnosed with active and moderate-to-severe TAO were enroled (responsive group, 48 patients; unresponsive group, 41 patients). The baseline clinical characteristics and texture features were compared between the two groups. Multivariate analysis was performed to identify the independent predictors of treatment response to IVGC. ROC analysis and the DeLong test were used to assess and compare the predictive performance of different models. RESULTS: The responsive group exhibited significantly shorter disease duration and higher 90th percentile of FS T2RT and kurtosis of WF in the extraocular muscle (EOM) and 95th percentile of WF in the orbital fat (OF) than the unresponsive group. Model 2 (disease duration + WF; AUC, 0.816) and model 3 (disease duration + FS T2RT + WF; AUC, 0.823) demonstrated superior predictive efficacy compared to model 1 (disease duration + FS T2RT; AUC, 0.756), while there was no significant difference between models 2 and 3. CONCLUSIONS: The orbital tissues of responders exhibited more oedema and heterogeneity. Furthermore, OF is as valuable as EOM for assessing the therapeutic efficacy of IVGC. Finally, WF derived from T2 IDEAL processed by texture analysis can provide valuable information for predicting the treatment response to IVGC in patients with active and moderate-to-severe TAO. CLINICAL RELEVANCE STATEMENT: The texture features of FS T2RT and WF are different between responders and non-responders, which can be the predictive tool for treatment response to IVGC. KEY POINTS: Texture analysis can be used for predicting response to IVGC in TAO patients. TAO patients responsive to IVGC show more oedema and heterogeneity in the orbital tissues. WF from T2 IDEAL is a tool to predict the therapeutic response of TAO.

4.
Magn Reson Med ; 89(1): 77-94, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36128895

ABSTRACT

PURPOSE: To evaluate the benefits and challenges of dynamic parallel transmit (pTx) pulses for fat saturation (FS) and water-excitation (WE), in the context of CEST MRI. METHODS: "Universal" kT -points (for FS) and spiral non-selective (for WE) trajectories were optimized offline for flip angle (FA) homogeneity. Routines to optimize the pulse shape online, based on the subject's fields maps, were implemented (target FA of 110°/0° for FS, 0°/5° for WE at fat/water frequencies). The pulses were inserted in a CEST sequence with a pTx readout. The different fat suppression schemes and their effects on CEST contrasts were compared in 12 volunteers at 7T. RESULTS: With a 25%-shorter pulse duration, pTx FS largely improved the FA homogeneity (root-mean-square-error (RMSE) = 12.3° vs. 53.4° with circularly-polarized mode, at the fat frequency). However, the spectral selectivity was degraded mainly in the cerebellum and close to the sinuses (RMSE = 5.8° vs. 0.2° at the water frequency). Similarly, pTx WE showed a trade-off between FA homogeneity and spectral selectivity compared to pTx non-selective pulses (RMSE = 0.9° and 1.1° at the fat and water frequencies, vs. 4.6° and 0.5°). In the brain, CEST metrics were reduced by up to 31.9% at -3.3 ppm with pTx FS, suggesting a mitigated lipid-induced bias. CONCLUSION: This clinically compatible implementation of dynamic pTx pulses improved the fat suppression homogeneity at 7T taking into account the subject-specific B0 heterogeneities online. This study highlights the lipid-induced biases on the CEST z-spectrum. The results are promising for body applications where B0 heterogeneities and fat are more substantial.


Subject(s)
Magnetic Resonance Imaging , Water , Humans , Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Contrast Media , Lipids , Algorithms
5.
Pol J Radiol ; 88: e562-e573, 2023.
Article in English | MEDLINE | ID: mdl-38362017

ABSTRACT

Purpose: To evaluate the feasibility of using a deep learning (DL) model to generate fat-suppression images and detect abnormalities on knee magnetic resonance imaging (MRI) through the fat-suppression image-subtraction method. Material and methods: A total of 45 knee MRI studies in patients with knee disorders and 12 knee MRI studies in healthy volunteers were enrolled. The DL model was developed using 2-dimensional convolutional neural networks for generating fat-suppression images and subtracting generated fat-suppression images without any abnormal findings from those with normal/abnormal findings and detecting/classifying abnormalities on knee MRI. The image qualities of the generated fat-suppression images and subtraction-images were assessed. The accuracy, average precision, average recall, F-measure, sensitivity, and area under the receiver operator characteristic curve (AUROC) of DL for each abnormality were calculated. Results: A total of 2472 image datasets, each consisting of one slice of original T1WI, original intermediate-weighted images, generated fat-suppression (FS)-intermediate-weighted images without any abnormal findings, generated FS-intermediate-weighted images with normal/abnormal findings, and subtraction images between the generated FS-intermediate-weighted images at the same cross-section, were created. The generated fat-suppression images were of adequate image quality. Of the 2472 subtraction-images, 2203 (89.1%) were judged to be of adequate image quality. The accuracies for overall abnormalities, anterior cruciate ligament, bone marrow, cartilage, meniscus, and others were 89.5-95.1%. The average precision, average recall, and F-measure were 73.4-90.6%, 77.5-89.4%, and 78.4-89.4%, respectively. The sensitivity was 57.4-90.5%. The AUROCs were 0.910-0.979. Conclusions: The DL model was able to generate fat-suppression images of sufficient quality to detect abnormalities on knee MRI through the fat-suppression image-subtraction method.

6.
Magn Reson Med ; 88(6): 2504-2519, 2022 12.
Article in English | MEDLINE | ID: mdl-36000548

ABSTRACT

PURPOSE: Two-dimensional (2D) echo-planar radiofrequency (RF) pulses are widely used for reduced field-of-view (FOV) imaging in applications such as diffusion-weighted imaging. However, long pulse durations render the 2D RF pulses sensitive to off-resonance effects, causing local signal losses in reduced-FOV images. This work aims to achieve off-resonance robustness for 2D RF pulses via a sheared trajectory design. THEORY AND METHODS: A sheared 2D RF pulse design is proposed to reduce pulse durations while covering identical excitation k-space extent as a standard 2D RF pulse. For a given shear angle, the number of sheared trajectory lines is minimized to obtain the shortest pulse duration, such that the excitation replicas are repositioned outside the slice stack to guarantee unlimited slice coverage. A target fat/water signal ratio of 5% is chosen to achieve robust fat suppression. RESULTS: Simulations, imaging experiments on a custom head and neck phantom, and in vivo imaging experiments in the spinal cord at 3 T demonstrate that the sheared 2D RF design provides significant improvement in image quality while preserving profile sharpnesses. In regions with high off-resonance effects, the sheared 2D RF pulse improves the signal by more than 50% when compared to the standard 2D RF pulse. CONCLUSION: The proposed sheared 2D RF design successfully reduces pulse durations, exhibiting significantly improved through-plane off-resonance robustness, while providing unlimited slice coverage and high fidelity fat suppression. This method will be especially beneficial in regions suffering from a variety of off-resonance effects, such as spinal cord and breast.


Subject(s)
Echo-Planar Imaging , Image Enhancement , Image Processing, Computer-Assisted , Adipose Tissue/diagnostic imaging , Body Water/diagnostic imaging , Diffusion Magnetic Resonance Imaging/methods , Echo-Planar Imaging/methods , Humans , Image Enhancement/methods , Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Signal-To-Noise Ratio
7.
Neuroimage ; 234: 117976, 2021 07 01.
Article in English | MEDLINE | ID: mdl-33781969

ABSTRACT

An efficient multi-slice inversion-recovery EPI (MS-IR-EPI) sequence for fast, high spatial resolution, quantitative T1 mapping is presented, using a segmented simultaneous multi-slice acquisition, combined with slice order shifting across multiple acquisitions. The segmented acquisition minimises the effective TE and readout duration compared to a single-shot EPI scheme, reducing geometric distortions to provide high quality T1 maps with a narrow point-spread function. The precision and repeatability of MS-IR-EPI T1 measurements are assessed using both T1-calibrated and T2-calibrated ISMRM/NIST phantom spheres at 3 and 7 T and compared with single slice IR and MP2RAGE methods. Magnetization transfer (MT) effects of the spectrally-selective fat-suppression (FS) pulses required for in vivo imaging are shown to shorten the measured in-vivo T1 values. We model the effect of these fat suppression pulses on T1 measurements and show that the model can remove their MT contribution from the measured T1, thus providing accurate T1 quantification. High spatial resolution T1 maps of the human brain generated with MS-IR-EPI at 7 T are compared with those generated with the widely implemented MP2RAGE sequence. Our MS-IR-EPI sequence provides high SNR per unit time and sharper T1 maps than MP2RAGE, demonstrating the potential for ultra-high resolution T1 mapping and the improved discrimination of functionally relevant cortical areas in the human brain.


Subject(s)
Brain Mapping/methods , Brain/diagnostic imaging , Echo-Planar Imaging/methods , Image Processing, Computer-Assisted/methods , Adult , Brain/metabolism , Female , Humans , Male
8.
Magn Reson Med ; 86(3): 1463-1471, 2021 09.
Article in English | MEDLINE | ID: mdl-33929055

ABSTRACT

PURPOSE: To develop a true single shot turbo spin echo (SShTSE) acquisition with Dixon for robust T2 -weighted abdominal imaging with uniform fat and water separation at 3T. METHODS: The in-phase (IP) and out-of-phase (OP) echoes for Dixon processing were acquired in the same repetition time of a SShTSE using partial echoes. A phase-preserved bi-directional homodyne reconstruction was developed to compensate the partial echo and the partial phase encoding of SShTSE. With IRB approval, the SShTSE-Dixon was compared against standard SShTSE, without and with fat suppression using spectral adiabatic inversion recovery (SPAIR) in 5 healthy volunteers and 5 patients. The SNR and contrast ratio (CR) of spleen to liver were compared among different acquisitions. RESULTS: The bi-directional homodyne reconstruction successfully minimized ringing artifacts because of partial acquisitions. SShTSE-Dixon achieved uniform fat suppression compared to SShTSE-SPAIR with fat suppression failures of 1/10 versus 10/10 in the axial plane and 0/5 versus 5/5 in the coronal plane, respectively. The SNRs of the liver (12.2 ± 4.9 vs. 11.7 ± 5.2; P = .76) and spleen (25.9 ± 11.6 vs. 23.7 ± 9.7; P = .14) were equivalent between fat-suppressed images (SShTSE-Dixon water-only and SShTSE-SPAIR). The SNRs of liver (14.4 ± 5.7 vs. 13.4 ± 5.0; P = .60) and spleen (26.5 ± 10.1 vs. 25.7 ± 8.5; P = .56) were equivalent between non-fat-suppressed images (SShTSE-Dixon IP and SShTSE). The CRs of spleen to liver were also similar between fat-suppressed images (2.6 ± 0.4 vs. 2.5 ± 0.5; P =.92) and non-fat-suppressed images (2.3 ± 0.6 vs. 2.2 ± 0.4; P =.84). CONCLUSION: SShTSE-Dixon generates robust abdominal T2 -weighted images at 3T with and without uniform fat suppression, along with perfectly co-registered fat-only images in a single acquisition.


Subject(s)
Magnetic Resonance Imaging , Water , Adipose Tissue/diagnostic imaging , Humans , Image Enhancement , Image Interpretation, Computer-Assisted
9.
Magn Reson Med ; 85(4): 2136-2144, 2021 04.
Article in English | MEDLINE | ID: mdl-33107146

ABSTRACT

PURPOSE: The recently introduced inhomogeneous magnetization transfer (ihMT) method has predominantly been applied for imaging the central nervous system. Future applications of ihMT, such as in peripheral nerves and muscles, will involve imaging in the vicinity of adipose tissues. This work aims to systematically investigate the partial volume effect of fat on the ihMT signal and to propose an efficient fat-separation method that does not interfere with ihMT measurements. METHODS: First, the influence of fat on ihMT signal was studied using simulations. Next, the ihMT sequence was combined with a multi-echo Dixon acquisition for fat separation. The sequence was tested in 9 healthy volunteers using a 3T human scanner. The ihMT ratio (ihMTR) values were calculated in regions of interest in the brain and the spinal cord using standard acquisition (no fat saturation), water-only, in-phase, and out-of-phase reconstructions. The values obtained were compared with a standard fat suppression method, spectral presaturation with inversion recovery. RESULTS: Simulations showed variations in the ihMTR values in the presence of fat, depending on the TEs used. The IhMTR values in the brain and spinal cord derived from the water-only ihMT multi-echo Dixon images were in good agreement with values from the unsuppressed sequence. The ihMT-spectral presaturation with inversion recovery combination resulted in 24%-35% lower ihMTR values compared with the standard non-fat-suppressed acquisition. CONCLUSION: The presence of fat within a voxel affects the ihMTR calculations. The IhMT multi-echo Dixon method does not compromise the observable ihMT effect and can potentially be used to remove fat influence in ihMT.


Subject(s)
Brain , Magnetic Resonance Imaging , Adipose Tissue/diagnostic imaging , Brain/diagnostic imaging , Healthy Volunteers , Humans , Spinal Cord
10.
Magn Reson Med ; 85(3): 1581-1589, 2021 03.
Article in English | MEDLINE | ID: mdl-32989787

ABSTRACT

PURPOSE: To evaluate 3D UTE bicomponent imaging of cortical bone ex vivo and in vivo using a newly designed soft-hard composite pulse for excitation. METHODS: Chemical shift artifacts, presenting as fat-water oscillation or combination-induced signal oscillation, significantly reduce the accuracy of quantitative UTE bicomponent analysis of cortical bone. To achieve fat suppression for more reliable bicomponent analysis, a newly developed soft-hard excitation pulse was used with UTE imaging and compared with a single rectangular pulse excitation without and with a conventional fat saturation (FatSat) module. These 3 sequences were applied to 8 bovine bone samples without marrow fat, 3 bovine bone samples with marrow fat, and tibial midshafts of 5 healthy human volunteers. Bicomponent analyses were performed in both ex vivo and in vivo studies. RESULTS: The soft-hard pulse provided comparable fat suppression, but much reduced bone signal attenuation compared with the FatSat module. Better bicomponent T2∗ fitting was also achieved with the soft-hard excitation pulse because it greatly reduced chemical shift artifacts and outperformed the single rectangular pulse without or with FatSat. Although the FatSat module reduced fat signals and related fat-water oscillation, the water signals were significantly attenuated with more than 40% reduction due to direction saturation. For the inner layer of tibial midshaft in healthy volunteers, fitting errors increased from 3.78% for the soft-hard pulse to 11.43% and 5.16%, respectively, for the single rectangular pulse without and with the FatSat module. CONCLUSION: The 3D UTE sequence with a new soft-hard excitation pulse allows more reliable bicomponent imaging of cortical bone.


Subject(s)
Cortical Bone , Magnetic Resonance Imaging , Animals , Bone and Bones/diagnostic imaging , Cattle , Cortical Bone/diagnostic imaging , Humans , Imaging, Three-Dimensional , Tibia/diagnostic imaging
11.
Magn Reson Med ; 86(3): 1434-1444, 2021 09.
Article in English | MEDLINE | ID: mdl-33759208

ABSTRACT

PURPOSE: Designing a new T2 -preparation (T2 -Prep) module to simultaneously provide robust fat suppression and efficient T2 preparation without requiring an additional fat-suppression module for T2 -weighted imaging at 3T. METHODS: The tip-down radiofrequency (RF) pulse of an adiabatic T2 -Prep module was replaced by a custom-designed RF-excitation pulse that induces a phase difference between water and fat, resulting in a simultaneous T2 preparation of water signals and the suppression of fat signals at the end of the module (a phaser adiabatic T2 -Prep). Numerical simulations and in vitro and in vivo electrocardiogram (ECG)-triggered navigator-gated acquisitions of the human heart were performed. Blood, myocardium, and fat signal-to-noise ratios and right coronary artery vessel sharpness were compared against previously published adiabatic T2 -Prep approaches. RESULTS: Numerical simulations predicted an increased fat-suppression bandwidth and decreased sensitivity to transmit magnetic field inhomogeneities using the proposed approach while preserving the water T2 -Prep capabilities. This was confirmed by the tissue signals acquired in the phantom and the in vivo images, which show similar blood and myocardium signal-to-noise ratio, contrast-to-noise ratio, and significantly reduced fat signal-to-noise ratio compared with the other methods. As a result, the right coronary artery conspicuity was significantly increased. CONCLUSION: A novel fat-suppressing T2 -Prep method was developed and implemented that showed robust fat suppression and increased vessel sharpness compared with conventional techniques while preserving its T2 -Prep capabilities.


Subject(s)
Magnetic Resonance Angiography , Magnetic Resonance Imaging , Coronary Vessels , Heart/diagnostic imaging , Humans , Phantoms, Imaging
12.
Magn Reson Med ; 85(3): 1379-1396, 2021 03.
Article in English | MEDLINE | ID: mdl-32981114

ABSTRACT

PURPOSE: To develop a fat-water imaging method that allows reliable separation of the two tissues, uses established robust reconstruction methods, and requires only one single-echo acquisition. THEORY AND METHODS: The proposed method uses spectrally selective dual-band excitation in combination with CAIPIRINHA to generate separate images of fat and water simultaneously. Spatially selective excitation without cross-contamination is made possible by the use of spatial-spectral pulses. Fat and water images can either be visualized separately, or the fat images can be corrected for chemical shift displacement and, in gradient echo imaging, for chemical shift-related phase discrepancy, and recombined with water images, generating fat-water images free of chemical shift effects. Gradient echo and turbo spin echo sequences were developed based on this Simultaneous Multiple Resonance Frequency imaging (SMURF) approach and their performance was assessed at 3Tesla in imaging of the knee, breasts, and abdomen. RESULTS: The proposed method generated well-separated fat and water images with minimal unaliasing artefacts or cross-excitation, evidenced by the near absence of water signal attributed to the fat image and vice versa. The separation achieved was similar to or better than that using separate acquisitions with water- and fat-saturation or Dixon methods. The recombined fat-water images provided similar image contrast to conventional images, but the chemical shift effects were eliminated. CONCLUSION: Simultaneous Multiple Resonance Frequency imaging is a robust fat-water imaging technique that offers a solution to imaging of body regions with significant amounts of fat.


Subject(s)
Diagnostic Imaging , Water , Adipose Tissue/diagnostic imaging , Artifacts , Diagnostic Tests, Routine , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Vibration
13.
NMR Biomed ; 34(10): e4580, 2021 10.
Article in English | MEDLINE | ID: mdl-34251717

ABSTRACT

Despite clinical use of late gadolinium enhancement (LGE) for two decades, an efficient, robust fat suppression (FS) technique still does not exist for this CMR mainstay. In ischemic and non-ischemic heart disease, differentiating fibrotic tissue from infiltrating and adjacent fat is crucial. Multiple groups have independently developed an FS technique for LGE, double spectral attenuated inversion recovery (DSPAIR), but no comprehensive evaluation was performed. This study aims to fill this gap. DSPAIR uses two SPAIR pulses and one non-selective IR pulse to enable FS LGE, including compatibility with phase sensitive inversion recovery (PSIR). We implemented a magnitude (MAGN) and a PSIR variant and compared them with LGE without FS (CONTROL) and with spectral presaturation with inversion recovery (SPIR) in simulations, phantoms, and patients. Fat magnetization by SPIR, MAGN DSPAIR, and PSIR DSPAIR was simulated as a function of pulse B1 , readout (RO) pulse number, and fat TI . A phantom with fat, fibrosis, and myocardium compartments was imaged using all FS methods and modifying pulse B1 , RO pulse number, and heart rate. Signal was measured in SNR units. Fat, myocardium, and fibrosis SNR and fibrosis-to-fat CNR were obtained. Patient images were acquired with all FS techniques. Fat, myocardium, and fibrosis SNR, fibrosis-to-fat CNR, and image and FS quality were assessed. In the phantom, both DSPAIR variants provided superior FS compared with SPIR, independent of heart rate and RO pulse number. MAGN DSPAIR reduced fat signal by 99% compared with CONTROL, PSIR DSPAIR by 116%, and SPIR by 67% (25 RO pulses). In patients, both DSPAIR variants substantially reduced fat signal (MAGN DSPAIR by 87.1% ± 10.0%, PSIR DSPAIR by 130.5% ± 36.3%), but SPIR did not (35.8% ± 25.5%). FS quality was good to excellent for MAGN and PSIR DSPAIR, and moderate to poor for SPIR. DSPAIR provided highly effective FS across a wide range of parameters. PSIR DSPAIR performed best.


Subject(s)
Gadolinium/chemistry , Lipids/chemistry , Magnetic Resonance Imaging , Arrhythmogenic Right Ventricular Dysplasia/diagnostic imaging , Computer Simulation , Humans , Middle Aged , Phantoms, Imaging , Signal-To-Noise Ratio
14.
BMC Musculoskelet Disord ; 22(1): 662, 2021 Aug 09.
Article in English | MEDLINE | ID: mdl-34372797

ABSTRACT

BACKGROUND: There is paucity of studies applying fat suppressed (FS) technique to T2 mapping to overcome chemical shift artifacts. The purpose of the study is to difference between FS T2 and conventional T2 mapping and reproducibility of FS T2 mapping in the femoral articular cartilage. METHODS: Eighteen patients who had normal-looking femoral cartilage and underwent knee MRI with conventional T2 and FS T2 mapping were included. T2 values of each mapping were measured by two readers independently from nine regions in the medial femoral condyle (MFC) and lateral femoral condyle (LFC). Each anatomical region was divided by lines at ± 10°, 30°, 50°, 70°, 90°, and 110°. Comparisons of T2 values between conventional and FS T2 mapping were statistically analyzed. The T2 values between FS and conventional T2 mapping in the anterior, central and posterior femoral condyles were compared. RESULTS: The overall femoral condyle T2 values from the FS T2 map were significantly lower than those from the conventional T2 map (48.5ms vs. 51.0ms, p < 0.001). The differences in the T2 values between the two maps were significantly different among the three divisions of the LFC (p = 0.009) and MFC (p = 0.031). The intra-class correlation coefficients indicated higher agreement in the FS T2 map than in the conventional T2 map (0.943 vs. 0.872). CONCLUSIONS: The T2 values of knee femoral cartilage are significantly lower on FS T2 mapping than on conventional T2 mapping. FS T2 mapping is a more reproducible method for evaluating knee femoral cartilage.


Subject(s)
Cartilage, Articular , Cartilage, Articular/diagnostic imaging , Femur/diagnostic imaging , Humans , Knee Joint/diagnostic imaging , Magnetic Resonance Imaging , Reproducibility of Results
15.
Magn Reson Med ; 83(3): 920-934, 2020 03.
Article in English | MEDLINE | ID: mdl-31532006

ABSTRACT

PURPOSE: The application of amide proton transfer (APT) CEST MRI for diagnosis of breast cancer is of emerging interest. However, APT imaging in the human breast is affected by the ubiquitous fat signal preventing a straightforward application of existing acquisition protocols. Although the spectral region of the APT signal does not coincide with fat resonances, the fat signal leads to an incorrect normalization of the Z-spectrum, and therefore to distorted APT effects. In this study, we propose a novel normalization for APT-CEST MRI that corrects for fat signal-induced artifacts in the postprocessing without the need for application of fat saturation schemes or water-fat separation approaches. METHODS: The novel normalization uses the residual signal at the spectral position of the direct water saturation to estimate the fat contribution. A comprehensive theoretical description of the normalization for an arbitrary phase relation of the water and fat signal is provided. Functionality and applicability of the proposed normalization was demonstrated by in vitro and in vivo experiments. RESULTS: In vitro, an underestimation of the conventional APT contrast of approximately -1.2% per 1% fat fraction was observed. The novel normalization yielded an APT contrast independent of the fat contribution, which was also independent of the water-fat phase relation. This allowed APT imaging in patients with mamma carcinoma corrected for fat signal contribution, field inhomogeneities, spillover dilution, and water relaxation effects. CONCLUSION: The proposed normalization increases the specificity of APT imaging in tissues with varying fat content and represents a time-efficient and specific absorption rate-efficient alternative to fat saturation and water-fat separation approaches.


Subject(s)
Adipose Tissue/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Magnetic Resonance Imaging , Adipose Tissue/pathology , Adult , Algorithms , Artifacts , Body Mass Index , Female , Healthy Volunteers , Humans , Hydrogen-Ion Concentration , Image Processing, Computer-Assisted , In Vitro Techniques , Middle Aged , Normal Distribution , Sunflower Oil , Temperature
16.
Magn Reson Med ; 84(3): 1470-1485, 2020 09.
Article in English | MEDLINE | ID: mdl-32144824

ABSTRACT

PURPOSE: To implement, optimize, and characterize lipid-insensitive binomial off-resonant RF excitation (LIBRE) pulses for fat-suppressed fully self-gated free-running 5D cardiac MRI. METHODS: Bloch equation simulations were used to optimize LIBRE parameter settings in non-interrupted bSSFP prior to in vitro validation. Thus, optimized LIBRE pulses were subsequently applied to free-running coronary MRA in 20 human adult subjects, where resulting images were quantitatively compared to those obtained with non-fat-suppressing excitation (SP), conventional 1-2-1 water excitation (WE), and a previously published interrupted free-running (IFR) sequence. SAR and scan times were recorded. Respiratory-and-cardiac-motion-resolved images were reconstructed with XD-GRASP, and contrast ratios, coronary artery detection rate, vessel length, and vessel sharpness were computed. RESULTS: The numerically optimized LIBRE parameters were successfully validated in vitro. In vivo, LIBRE had the lowest SAR and a scan time that was similar to that of WE yet 18% shorter than that of IFR. LIBRE improved blood-fat contrast when compared to SP, WE, and IFR, vessel detection relative to SP and IFR, and vessel sharpness when compared to WE and IFR (for example, for the left main and anterior descending coronary artery, 51.5% ± 10.2% [LIBRE] versus 42.1% ± 6.8% [IFR]). Vessel length measurements remained unchanged for all investigated methods. CONCLUSION: LIBRE enabled fully self-gated non-interrupted free-running 5D bSSFP imaging of the heart at 1.5T with suppressed fat signal. Measures of image quality, vessel conspicuity, and scan time compared favorably to those obtained with the more conventional non-interrupted WE and the previously published IFR, while SAR reduction offers added flexibility.


Subject(s)
Heart , Water , Adult , Coronary Angiography , Coronary Vessels/diagnostic imaging , Humans , Imaging, Three-Dimensional , Lipids , Magnetic Resonance Angiography , Magnetic Resonance Imaging
17.
Magn Reson Med ; 83(1): 45-55, 2020 01.
Article in English | MEDLINE | ID: mdl-31452244

ABSTRACT

PURPOSE: To implement, optimize, and test fast interrupted steady-state (FISS) for natively fat-suppressed free-running 5D whole-heart MRI at 1.5 tesla (T) and 3T. METHODS: FISS was implemented for fully self-gated free-running cardiac- and respiratory-motion-resolved radial imaging of the heart at 1.5T and 3T. Numerical simulations and phantom scans were performed to compare fat suppression characteristics and to determine parameter ranges (number of readouts [NR] per FISS module and TR) for effective fat suppression. Subsequently, free-running FISS data were collected in 10 healthy volunteers and images were reconstructed with compressed sensing. All acquisitions were compared with a continuous balanced steady-state free precession version of the same sequence, and both fat suppression and scan times were analyzed. RESULTS: Simulations demonstrate a variable width and location of suppression bands in FISS that were dependent on TR and NR. For a fat suppression bandwidth of 100 Hz and NR ≤ 8, simulations demonstrated that a TR between 2.2 ms and 3.0 ms is required at 1.5T, whereas a range of 3.0 ms to 3.5 ms applies at 3T. Fat signal increases with NR. These findings were corroborated in phantom experiments. In volunteers, fat SNR was significantly decreased using FISS compared with balanced steady-state free precession (P < 0.05) at both field strengths. After protocol optimization, high-resolution (1.1 mm3 ) 5D whole-heart free-running FISS can be performed with effective fat suppression in under 8 min at 1.5T and 3T at a modest scan time increase compared to balanced steady-state free precession. CONCLUSION: An optimal FISS parameter range was determined enabling natively fat-suppressed 5D whole-heart free-running MRI with a single continuous scan at 1.5T and 3T, demonstrating potential for cardiac imaging and noncontrast angiography.


Subject(s)
Free Radicals , Heart/diagnostic imaging , Magnetic Resonance Imaging , Respiratory-Gated Imaging Techniques , Algorithms , Computer Simulation , Coronary Angiography , Electrocardiography , Healthy Volunteers , Humans , Image Processing, Computer-Assisted , Models, Theoretical , Motion , Normal Distribution , Phantoms, Imaging , Signal-To-Noise Ratio
18.
Radiol Med ; 125(1): 1-6, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31562581

ABSTRACT

PURPOSE: To evaluate the influence of fat deposition on T1 relaxation time of pancreatic parenchyma using dual-flip-angle T1 mapping with and without fat suppression. METHODS: Forty-five patients who underwent abdominal MR imaging including T1 mapping with dual-flip-angle method on 3T MRI were included. We measured T1 relaxation time of pancreatic parenchyma on the T1 map images with and without fat suppression. T1 relaxation time of bone marrow was also measured as a reference organ with abundant fat deposition. Fat signal fraction (FSF) was also measured at the same location as T1 map images. Then, the correlation between T1 relaxation time and FSF was assessed. RESULTS: T1 relaxation times of pancreatic parenchyma and bone marrow on the T1 map images without fat suppression showed significantly negative correlation with FSF (pancreas, r = - 0.394, P = 0.007; bone marrow, r = - 0.550, P < 0.001), while there were no significant correlations between them on the T1 map images with fat suppression. On the T1 map images without fat suppression, T1 relaxation times of pancreatic parenchyma as well as bone marrow in patients with FSF ≥ 10% were significantly shorter than those in patients with FSF < 10% (pancreas, P = 0.041; bone marrow, P = 0.005). Conversely, on the T1 map images with fat suppression, no significant differences in T1 relaxation times were found between two groups. CONCLUSION: T1 relaxation time of the pancreas on T1 mapping was influenced by the presence of fat deposition. Therefore, fat suppression technique in T1 mapping will be essential for evaluating T1 relaxation time of pancreatic parenchyma.


Subject(s)
Adipose Tissue/diagnostic imaging , Magnetic Resonance Imaging/methods , Pancreas/diagnostic imaging , Pancreatic Diseases/diagnostic imaging , Subtraction Technique , Aged , Aged, 80 and over , Bone Marrow/diagnostic imaging , Female , Humans , Male , Middle Aged , Pancreatic Neoplasms/diagnostic imaging , Reference Standards , Retrospective Studies , Time Factors
19.
Magn Reson Med ; 81(4): 2385-2398, 2019 04.
Article in English | MEDLINE | ID: mdl-30394582

ABSTRACT

PURPOSE: To perform multi-echo water/fat separated proton resonance frequency (PRF)-shift temperature mapping. METHODS: State-of-the-art, iterative multi-echo water/fat separation algorithms produce high-quality water and fat images in the absence of heating but are not suitable for real-time imaging due to their long compute times and potential errors in heated regions. Existing fat-referenced PRF-shift temperature reconstruction methods partially address these limitations but do not address motion or large time-varying and spatially inhomogeneous B0 shifts. We describe a model-based temperature reconstruction method that overcomes these limitations by fitting a library of separated water and fat images measured before heating directly to multi-echo data measured during heating, while accounting for the PRF shift with temperature. RESULTS: Simulations in a mixed water/fat phantom with focal heating showed that the proposed algorithm reconstructed more accurate temperature maps in mixed tissues compared to a fat-referenced thermometry method. In a porcine phantom experiment with focused ultrasound heating at 1.5 Tesla, temperature maps were accurate to within 1∘ C of fiber optic probe temperature measurements and were calculated in 0.47 s per time point. Free-breathing breast and liver imaging experiments demonstrated motion and off-resonance compensation. The algorithm can also accurately reconstruct water/fat separated temperature maps from a single echo during heating. CONCLUSIONS: The proposed model-based water/fat separated algorithm produces accurate PRF-shift temperature maps in mixed water and fat tissues in the presence of spatiotemporally varying off-resonance and motion.


Subject(s)
Adipose Tissue/chemistry , Liver/diagnostic imaging , Magnetic Resonance Imaging/methods , Thermography/methods , Water/chemistry , Algorithms , Animals , Breast/diagnostic imaging , Computer Simulation , Female , Healthy Volunteers , Heating , Humans , Image Processing, Computer-Assisted/methods , Models, Statistical , Motion , Reproducibility of Results , Swine , Temperature , Ultrasonography
20.
Magn Reson Med ; 81(1): 477-485, 2019 01.
Article in English | MEDLINE | ID: mdl-30058204

ABSTRACT

PURPOSE: Echo planar imaging (EPI) is the primary sequence for functional and diffusion MRI. In fetal applications, the large field of view needed to encode the maternal abdomen leads to prolonged EPI readouts, which may be further extended due to safety considerations that limit gradient performance. The resulting images become very sensitive to water-fat shift and susceptibility artefacts. The purpose of this study was to reduce artefacts and increase stability of EPI in fetal brain imaging, balancing local field homogeneity across the fetal brain with longer range variations to ensure compatibility with fat suppression of the maternal abdomen. METHODS: Spectral Pre-saturation with Inversion-Recovery (SPIR) fat suppression was optimized by investigating SPIR pulse frequency offsets. Subsequently, fetal brain EPI data were acquired using image-based (IB) shimming on 6 pregnant women by (1) minimizing B0 field variations within the fetal brain (localized IB shimming) and (2) with added constraint to limit B0 variation in maternal fat (fat constrained IB shimming). RESULTS: The optimal offset for the SPIR pulse at 3 Tesla was 550 Hz. Both shimming approaches had similar performances in terms of B0 homogeneity within the brain, but constrained IB shimming enabled higher fat suppression efficiency. CONCLUSION: Optimized SPIR in combination with constrained IB shimming can improve maternal fat suppression while minimizing EPI distortions in the fetal brain.


Subject(s)
Adipose Tissue/diagnostic imaging , Diffusion Magnetic Resonance Imaging , Echo-Planar Imaging , Fetus/diagnostic imaging , Image Processing, Computer-Assisted/methods , Prenatal Diagnosis/methods , Abdomen/diagnostic imaging , Algorithms , Artifacts , Brain/diagnostic imaging , Brain/embryology , Female , Humans , Image Enhancement/methods , Patient Safety , Pregnancy
SELECTION OF CITATIONS
SEARCH DETAIL