Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J Arthroplasty ; 33(6): 1820-1825, 2018 06.
Article in English | MEDLINE | ID: mdl-29429884

ABSTRACT

INTRODUCTION: Hard-on-hard (HoH) bearing surfaces in total hip arthroplasty (THA) are commonly utilized in younger patients and may decrease mechanical wear compared to polyethylene bearing surfaces. To our knowledge, no study has prospectively compared the 2 most common HoH bearings, ceramic-on-ceramic (CoC) and metal-on-metal (MoM) THA. MATERIALS AND METHODS: We prospectively enrolled 40 patients to undergo an MoM THA and 42 patients to undergo a CoC THA utilizing the same acetabular component. Patients were followed up for a minimum of 2 years. Comparative outcomes included clinical scores, revision or reoperation for any reason, complication rates, and radiographic outcomes. RESULTS: The average follow-up was significantly longer in the CoC cohort (94 vs 74 months; P = .005). The CoC cohort had significantly improved Harris Hip Scores (95 vs 84; P = .0009) and pain scores (42 vs 34; P = .0003). The revision (0% vs 31%; P = .0001), reoperation (7.5% vs 36%; P = .004), and complication rates (10% vs 56%; P = .0001) were significantly lower in the CoC cohort. There were no statistically significant differences in radiographic parameters. CONCLUSION: The clinical outcomes in the CoC cohort exceeded the MoM cohort. It is unlikely that another prospective comparative study of HoH THAs will be conducted. Our midterm results support the use of CoC THA as a viable option that may reduce long-term wear in younger patients. Close surveillance of MoM THA patients is recommended considering the higher failure and complication rates reported in this cohort.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis/statistics & numerical data , Metal-on-Metal Joint Prostheses/statistics & numerical data , Acetabulum , Aged , Ceramics , Female , Hip Prosthesis/adverse effects , Humans , Male , Metal-on-Metal Joint Prostheses/adverse effects , Middle Aged , Polyethylene , Postoperative Complications/etiology , Prospective Studies , Prosthesis Design , Prosthesis Failure , Reoperation
2.
Hip Int ; 30(2_suppl): 52-58, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33267696

ABSTRACT

INTRODUCTION: The aim of this study is to evaluate clinical, radiographic and laboratory results of ceramic-on-metal (CoM) (hybrid hard bearing) in total hip arthroplasty (THA), associated with a short stem implant. METHODS: From a cohort of 37 patients suffering from primary or secondary hip osteoarthritis who underwent THA using CoM bearing, 19 were suitable for this study. All procedures were performed by the same surgeon using a posterior-lateral approach. All patients were compared clinically using the Harris Hip Score (HHS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), visual analogue scale (VAS), 12-item Short Form Health Survey (SF12F/M), and radiographically (offset, CD angle, limb length discrepancy, cup inclination and anteversion, subsidence, osseointegration, heterotopic ossification). Blood samples were collected in order to evaluate chromium (Cr) and cobalt (Co) ions level. Radiographic evaluations were carried out by 3 different blinded surgeons. A statistical analysis was performed. RESULTS: At a mean follow-up of 97 (73-125) months all implanted stems were well-positioned and osseointegrated. Clear improvements were observed for clinical scores comparing preoperative and postoperative values. Radiographic evaluation showed a good ability to restore proper articular geometry. Cr ion analysis revealed values below the safety threshold except for 1 case. Serum levels of Co were below the threshold in all patients. There was a statistically significant correlation only between Cr metal ions and length of follow-up. CONCLUSIONS: CoM bearing has proven to be reliable and safe at a mean 8-year follow-up for patients in whom the components were correctly implanted. The rise of blood metal ions was minimal and involved neither systemic or local toxicity nor influenced clinical results.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Arthroplasty, Replacement, Hip/adverse effects , Ceramics , Follow-Up Studies , Humans , Ions , Prosthesis Design
3.
Materials (Basel) ; 10(7)2017 Jul 01.
Article in English | MEDLINE | ID: mdl-28773095

ABSTRACT

Recently, concerns have been raised about the potential effect of head-neck junction damage products at the local and systemic levels. Factors that may affect this damage process have not been fully established yet. This study investigated the possible correlations among head-neck junction damage level, implant design, material combination, and patient characteristics. Head-neck junctions of 148 retrieved implants were analysed, including both ceramic-on-ceramic (N = 61) and metal-on-metal (N = 87) bearings. In all cases, the male taper was made of titanium alloy. Damage was evaluated using a four-point scoring system based on damage morphology and extension. Patient age at implantation, implantation time, damage risk factor, and serum ion concentration were considered as independent potential predicting variables. The damage risk factor summarises head-neck design characteristics and junction loading condition. Junction damage correlated with both implantation time and damage factor risk when the head was made of ceramic. A poor correlation was found when the head was made of cobalt alloy. The fretting-corrosion phenomenon seemed mainly mechanically regulated, at least when cobalt alloy components were not involved. When a component was made of cobalt alloy, the role of chemical phenomena increased, likely becoming, over implantation time, the damage driving phenomena of highly stressed junctions.

4.
Bone Joint J ; 99-B(11): 1435-1441, 2017 Nov.
Article in English | MEDLINE | ID: mdl-29092981

ABSTRACT

AIMS: The Corail stem has good long-term results. After four years of using this stem, we have detected a small group of patients who have presented with symptomatic metaphyseal debonding. The aim of this study was to quantify the incidence of this complication, to delineate the characteristics of patients presenting with this complication and to compare these patients with asymptomatic controls to determine any important predisposing factors. PATIENTS AND METHODS: Of 855 Corail collarless cementless stems implanted for osteoarthritis, 18 presented with symptomatic metaphyseal debonding. A control group of 74 randomly selected patients was assembled. Clinical and radiological parameters were measured and a logistic regression model was created to evaluate factors associated with metaphyseal debonding. RESULTS: The prevalence of this complication was 2.1% in our series. In the multivariable model, the presence of a Dorr B-type proximal femur was associated with metaphyseal debonding (odds ratio (OR) 10.73, 95% confidence interval (CI) 2.31 to 49.97, p = 0.002), as was a body mass index > 25 kg/m2 (OR 6.85, 95% CI 1.06 to 44.28, p = 0.04). Smaller stems and the use of a polyethylene acetabular liner appeared to be protective when compared with metal and ceramic setting hard-on-hard bearings. CONCLUSION: We have described an uncommon but important mode of failure of the Corail stem. Surgeons should be aware of this phenomenon; overweight patients with Dorr B-type femurs and in whom hard bearings are used appear to be particularly at risk. Cite this article: Bone Joint J 2017;99-B:1435-41.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis , Osteoarthritis, Hip/surgery , Prosthesis Failure , Adult , Aged , Aged, 80 and over , Case-Control Studies , Female , Follow-Up Studies , Humans , Logistic Models , Male , Middle Aged , Multivariate Analysis , Prosthesis Failure/etiology , Retrospective Studies , Risk Factors , Treatment Outcome
5.
Bone Joint J ; 97-B(3): 300-5, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25737511

ABSTRACT

Ceramic-on-metal (CoM) is a relatively new bearing combination for total hip arthroplasty (THA) with few reported outcomes. A total of 287 CoM THAs were carried out in 271 patients (mean age 55.6 years (20 to 77), 150 THAs in female patients, 137 in male) under the care of a single surgeon between October 2007 and October 2009. With the issues surrounding metal-on-metal bearings the decision was taken to review these patients between March and November 2011, at a mean follow-up of 34 months (23 to 45) and to record pain, outcome scores, radiological analysis and blood ion levels. The mean Oxford Hip Score was 19.2 (12 to 53), 254 patients with 268 hips (95%) had mild/very mild/no pain, the mean angle of inclination of the acetabular component was 44.8(o) (28(o) to 63(o)), 82 stems (29%) had evidence of radiolucent lines of > 1 mm in at least one Gruen zone and the median levels of cobalt and chromium ions in the blood were 0.83 µg/L (0.24 µg/L to 27.56 µg/L) and 0.78 µg/L (0.21 µg/L to 8.84 µg/L), respectively. The five-year survival rate is 96.9% (95% confidence interval 94.7% to 99%). Due to the presence of radiolucent lines and the higher than expected levels of metal ions in the blood, we would not recommend the use of CoM THA without further long-term follow-up. We plan to monitor all these patients regularly.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Ceramics , Hip Prosthesis , Metals , Adult , Aged , Chromium/blood , Cobalt/blood , Female , Humans , Ions/blood , Male , Metals/blood , Middle Aged , Osteoarthritis, Hip/surgery , Pain Measurement , Population Surveillance , Prosthesis Design , Prosthesis Failure , Reoperation , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL