Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 138
Filter
Add more filters

Publication year range
1.
Clin Orthop Relat Res ; 479(7): 1548-1558, 2021 Jul 01.
Article in English | MEDLINE | ID: mdl-33729206

ABSTRACT

BACKGROUND: During the last 5 years, there has been an increase in the use of unicompartmental knee arthroplasty (UKA) to treat knee osteoarthritis in Australia, and these account for almost 6% of annual knee replacement procedures. However, there is debate as to whether a fixed bearing or a mobile bearing design is best for decreasing revision for loosening and disease progression as well as improving survivorship. Small sample sizes and possible confounding in the studies on the topic may have masked differences between fixed and mobile bearing designs. QUESTIONS/PURPOSES: Using data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), we selected the four contemporary designs of medial compartment UKA: mobile bearing, fixed modular, all-polyethylene, and fixed molded metal-backed used for the treatment of osteoarthritis to ask: (1) How do the different designs of unicompartmental knees compare with survivorship as measured by cumulative percentage revision (CPR)? (2) Is there a difference in the revision rate between designs as a function of patient sex or age? (3) Do the reasons for revision differ, and what types of revision procedures are performed when these UKA are revised? METHODS: The AOANJRR longitudinally maintains data on all primary and revision joint arthroplasties, with nearly 100% capture. The study population included all UKA procedures undertaken for osteoarthritis between September 1999 and December 2018. Of 56,628 unicompartmental knees recorded during the study period, 50,380 medial UKA procedures undertaken for osteoarthritis were included in the analysis after exclusion of procedures with unknown bearing types (31 of 56,628), lateral or patellofemoral compartment UKA procedures (5657 of 56,628), and those performed for a primary diagnosis other than osteoarthritis (560 of 56,628). There were 50,380 UKA procedures available for analysis. The study group consisted of 40% (20,208 of 50,380) mobile bearing UKA, 35% (17,822 of 50,380) fixed modular UKA, 23% (11,461 of 50,380) all-polyethylene UKA, and 2% (889 of 50,380) fixed molded metal-backed UKA. There were similar sex proportions and age distributions for each bearing group. The overall mean age of patients was 65 ± 9.4 years, and 55% (27,496 of 50,380) of patients were males. The outcome measure was the CPR, which was defined using Kaplan-Meier estimates of survivorship to describe the time to the first revision. Hazard ratios from Cox proportional hazards models, adjusted for sex and age, were performed to compare the revision rates among groups. The cohort was stratified into age groups of younger than 65 years and 65 years and older to compare revision rates as a function of age. Differences among bearing groups for the major causes and modes of revision were assessed using hazard ratios. RESULTS: At 15 years, fixed modular UKA had a CPR of 16% (95% CI 15% to 17%). In comparison, the CPR was 23% (95% CI 22% to 24%) for mobile bearing UKA, 26% (95% CI 24% to 27%) for all-polyethylene UKA, and 20% (95% CI 16% to 24%) for fixed molded metal-backed UKA. The lower revision rate for fixed modular UKA was seen through the entire period compared with mobile bearing UKA (hazard ratio 1.5 [95% CI 1.4 to 1.6]; p < 0.001) and fixed molded metal-backed UKA (HR 1.3 [95% CI 1.1 to 1.6]; p = 0.003), but it varied with time compared with all-polyethylene UKA. The findings were consistent when stratified by sex or age. Although all-polyethylene UKA had the highest revision rate overall and for patients younger than 65 years, for patients aged 65 years and older, there was no difference between all-polyethylene and mobile bearing UKA. When compared with fixed modular UKA, a higher revision risk for loosening was shown in both mobile bearing UKA (HR 1.7 [95% CI 1.5 to 1.9]; p < 0.001) and all-polyethylene UKA (HR 2.4 [95% CI 2.1 to 2.7]; p < 0.001). The revision risk for disease progression was higher for all-polyethylene UKA at all time points (HR 1.4 [95% CI 1.3 to 1.6]; p < 0.001) and for mobile bearing UKA after 8 years when each were compared with fixed modular UKA (8 to 12 years: HR 1.4 [95% CI 1.2 to 1.7]; p < 0.001; 12 or more years: HR 1.9 [95% CI 1.5 to 2.3]; p < 0.001). The risk of revision to TKA was higher for mobile bearing UKA compared with fixed modular UKA (HR 1.4 [95% CI 1.3 to 1.5]; p < 0.001). CONCLUSION: If UKA is to be considered for the treatment of isolated medial compartment osteoarthritis, the fixed modular UKA bearing has the best survivorship of the current UKA designs. LEVEL OF EVIDENCE: Level III, therapeutic study.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Knee Prosthesis/statistics & numerical data , Medial Collateral Ligament, Knee/surgery , Prosthesis Design/statistics & numerical data , Reoperation/statistics & numerical data , Aged , Australia , Female , Humans , Kaplan-Meier Estimate , Longitudinal Studies , Male , Metals , Middle Aged , Polyethylene , Registries , Treatment Outcome
2.
Acta Orthop ; 92(1): 36-39, 2021 02.
Article in English | MEDLINE | ID: mdl-33172317

ABSTRACT

Background and purpose - Dislocation is one of the most frequent reasons for cup revision after total hip arthroplasty (THA) for an acute fracture. A dual mobility cup (DMC) might reduce this risk. We determined the cup revision rate after THA for an acute fracture according to type of cup.Patients and methods - All THAs for an acute fracture registered in the Dutch Arthroplasty Register (LROI) during 2007-2019 were included (n = 11,857). Type of cup was divided into DMC and unipolar cup (UC). Competing risk analyses were performed with cup revision for any reason as endpoint. Multivariable Cox regression analyses with outcome cup revision were performed adjusted for sex, age, ASA class, and surgical approach, stratified for UC THA with femoral head size of 32 mm and 22-28 mm.Results - A DMC was used in 1,122 (9%) hips. The overall 5-year cup revision rate for any reason after THA for acute fracture was 1.9% (95% CI 1.6-2.2). Cup revision for dislocation within 5 years was performed in 1 of 6 DMC THAs versus 108 of 185 (58%) UC THAs. Univariable Cox regression analyses showed no statistically significant difference in cup revision rate between DMC and UC (HR = 0.8; CI 0.4-1.5). Multivariable Cox regression analyses showed lower risk of cup revision in DMC THA (n = 1,122) compared with UC THA with 22-28 mm femoral head size (n = 2,727) (HR = 0.4; CI 0.2-0.8).Interpretation - The 5-year cup cumulative incidence of revision after THA for acute fracture was comparable for DMC and UC THA. However, DMC THA had a lower risk of cup revision than UC THA with 22-28 mm femoral head.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Fractures/surgery , Hip Prosthesis/statistics & numerical data , Prosthesis Design/statistics & numerical data , Prosthesis Failure , Reoperation/statistics & numerical data , Aged , Aged, 80 and over , Female , Hip Fractures/etiology , Humans , Male , Middle Aged , Netherlands , Postoperative Complications/etiology , Postoperative Complications/surgery
3.
Int Urogynecol J ; 31(2): 291-301, 2020 02.
Article in English | MEDLINE | ID: mdl-31312846

ABSTRACT

INTRODUCTION AND HYPOTHESIS: As the long-term complications of synthetic mesh become increasingly apparent, re-evaluation of alternative graft options for pelvic organ prolapse (POP) repairs is critical. We sought to compare the long-term reoperation rates of biologic and synthetic grafts in POP repair. METHODS: Using the California Office of Statewide Health Planning and Development database, we identified all women who underwent index inpatient POP repair with either a synthetic or biologic graft between 2005 and 2011 in the state of California. ICD-9 and CPT codes were used to identify subsequent surgeries in these patients for either recurrent POP or a graft complication. RESULTS: A total of 14,192 women underwent POP repair with a biologic (14%) or synthetic graft (86%) during the study period. Women with biologic grafts had increased rates of surgery for recurrent pelvic organ prolapse (3.6% vs 2.5%, p = 0.01), whereas women with synthetic grafts had higher rates of repeat surgery for a graft complication (3.0 vs 2.0%, p = 0.02). There were no significant differences between the overall risk of repeat surgery between the groups (5.7% vs 5.6%, p = 0.79). These effects persisted in multivariate modeling. CONCLUSIONS: We demonstrate in a large population-based cohort that biologic grafts are associated with an increased rate of repeat surgery for POP recurrence whereas synthetic mesh is associated with an increased rate of repeat surgery for a graft complication. These competing risks result in an equivalent overall any-cause repeat surgery rate between the groups. These data suggest that neither type of graft should be excluded from use and encourage a personalized risk assessment.


Subject(s)
Pelvic Organ Prolapse/surgery , Postoperative Complications/surgery , Prosthesis Design/statistics & numerical data , Reoperation/statistics & numerical data , Surgical Mesh/statistics & numerical data , Biological Products/therapeutic use , California , Databases, Factual , Female , Humans , Kaplan-Meier Estimate , Longitudinal Studies , Middle Aged , Postoperative Complications/etiology , Prosthesis Design/adverse effects , Recurrence , Retrospective Studies , Surgical Mesh/adverse effects , Synthetic Biology , Transplants/surgery , Treatment Outcome
4.
Knee Surg Sports Traumatol Arthrosc ; 28(12): 3805-3809, 2020 Dec.
Article in English | MEDLINE | ID: mdl-31993682

ABSTRACT

PURPOSE: Medial pivot (MP) TKA has been shown to mimic normal knee kinematics with long-term survivorship comparable to most contemporary TKA. However, there are inadequate evidences to suggest its superiority in terms of patient preference and satisfaction. The aim of this study is to compare the MP with posterior-stabilized (PS) TKA in terms of patient preference and satisfaction. METHODS: 46 patients with staged bilateral TKA were recruited. TKA with MP or PS design was performed at interval of 6-12 months. Patient preference, patient satisfaction score (0-100), Forgotten Joint Score (FJS), range of motion (ROM), Pain Score, Knee Society Score (KSS), Knee Function Score (KFS) and WOMAC Score were compared at up to 12 months. RESULTS: The mean age was 70 and 69.6% were female. There was no difference in all preoperative parameters, operative time and length of stay between two knees. No difference was found in in range of motion and all outcome scores at 6 months and 12 months. Satisfaction score was similar for the two designs (82 vs 85, p = n.s.) at 1 year after the second TKA. Proportion of patients with preference on one design over another was not significantly different (28.9 vs 35.6%, p = n.s.). CONCLUSIONS: There is no evidence to support the superiority of MP TKA over PS TKA in terms of preference and satisfaction. The choice between MP TKA versus PS TKA maybe more a surgeon's preference than a patient's preference based on current evidence.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Knee Prosthesis/statistics & numerical data , Patient Preference/statistics & numerical data , Prosthesis Design/statistics & numerical data , Aged , Aged, 80 and over , Biomechanical Phenomena , Female , Humans , Knee Joint/surgery , Knee Prosthesis/psychology , Male , Middle Aged , Prospective Studies , Range of Motion, Articular
5.
Int Urogynecol J ; 30(9): 1465-1473, 2019 09.
Article in English | MEDLINE | ID: mdl-31222572

ABSTRACT

INTRODUCTION AND HYPOTHESIS: The aim of this study was to compare the long-term subjective outcomes of an adjustable single-incision sling (Ajust®) vs standard mid-urethral slings (SMUS) for the treatment of women with stress urinary incontinence. METHODS: This study was designed as a multicenter prospective randomized trial. Women under 60 years old with objectively verified stress urinary incontinence were included from seven centers in three countries. Women with mixed urinary incontinence were also included. Randomization was held in blocks for operation with either Ajust® or SMUS. Women analyzed at 1-year follow-up received the International Consultation on Incontinence Questionnaire Urinary Incontinence Short Form (ICIQ-UI-SF), International Consultation on Incontinence Questionnaire Overactive Bladder, Pelvic Organ Prolapse/Urinary Incontinence/Sexual Function Questionnaire-12, Patient Global Impression of Severity, and Patient Global Impression of Improvement questionnaires, together with a bladder diary to fill out at least 3 years after the procedure. The main outcome evaluated was the subjective cure rate as reported through the ICIQ-UI-SF questionnaire at 3 years. RESULTS: In total, 205 women participated in the 3-year follow-up: 107 in the Ajust® and 98 in the SMUS group. No significant difference was observed between the groups regarding subjective cure rate (50.9% vs 51.5%, p = 0.909) or dyspareunia. Both groups demonstrated similar postoperative perception of improvement in addition to reduced urgency and urge urinary incontinence. The postoperative improvement remained at the same level after 3 years as it was at 1-year follow-up for both Ajust® and SMUS. CONCLUSIONS: Ajust® appears to be equally effective and safe as SMUS with regard to long-term follow-up of patient-reported outcomes.


Subject(s)
Prosthesis Design/statistics & numerical data , Suburethral Slings , Urinary Incontinence, Stress/surgery , Female , Follow-Up Studies , Humans , Middle Aged , Postoperative Period , Prospective Studies , Quality of Life , Surveys and Questionnaires , Time Factors , Treatment Outcome
6.
J Arthroplasty ; 34(12): 3074-3079, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31383495

ABSTRACT

BACKGROUND: Periprosthetic femur fractures are a well-documented complication following direct anterior uncemented total hip arthroplasty. The purpose of this study is to compare the prevalence of postoperative periprosthetic femur fractures between 2 different femoral component designs used in direct anterior total hip arthroplasty. METHODS: Beginning in February 2015, a single fellowship-trained adult reconstruction surgeon performed 361 consecutive direct anterior total hip replacements using a flat, single-taper, wedged femoral implant. In June 2016, that same surgeon, using the exact same surgical technique and postoperative weight-bearing protocol, began using a dual-taper, hydroxyapatite-coated implant for 789 consecutive hips. The patients were carefully monitored for 3 months after surgery to identify the frequency of periprosthetic femur fractures. A Fisher's exact test was used to determine if the prevalence of periprosthetic femur fractures differed between the 2 implant designs. RESULTS: Five of 361 (1.4%) patients sustained proximal femur fractures at an average of 19.6 days postoperatively in the first group, all demonstrating a Vancouver type B2 periprosthetic fracture and requiring femoral revision. No patients (0/789, 0%) in the second cohort sustained a postoperative, periprosthetic fracture (P = .006). CONCLUSION: In this comparison of 2 consecutive cohorts, the dual-taper, hydroxyapatite-coated implant had a statistically significant lower postoperative periprosthetic fracture rate than a flat, single-taper, wedged design.


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Femoral Fractures/etiology , Hip Prosthesis/adverse effects , Periprosthetic Fractures/etiology , Prosthesis Design/adverse effects , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/instrumentation , Female , Femoral Fractures/epidemiology , Femur/surgery , Hip Prosthesis/statistics & numerical data , Humans , Kentucky/epidemiology , Middle Aged , Periprosthetic Fractures/epidemiology , Postoperative Period , Prevalence , Prosthesis Design/statistics & numerical data , Young Adult
7.
J Arthroplasty ; 34(12): 3114-3123.e3, 2019 12.
Article in English | MEDLINE | ID: mdl-31474324

ABSTRACT

BACKGROUND: Prior studies have compared fixed-bearing unicompartmental knee arthroplasty (FB-UKA) with mobile-bearing UKA (MB-UKA), suggesting that both procedures have good clinical outcomes. However, which treatment is more beneficial for patients is controversial. The purpose of our study is to evaluate the postoperative outcomes, including the revision rate, complications, functional results, range of motion, and femoral-tibial angle, between the 2 procedures. METHODS: We searched the MEDLINE, EMBASE, Cochrane Library, and Web of Science databases starting from August 2017 to May 2018. The publication date of articles was not restricted. Before we submit our contribution, we have re-searched it again. Articles that directly compared the postoperative outcomes of the 2 prosthesis type were included. RESULTS: A total of 15 comparative studies were included in our meta-analysis. The pooled data indicated no differences between the 2 operation modes in terms of revision rates, complications, and knee function, but earlier failure occurred more frequently with the MB design. CONCLUSION: Both the arthroplasty types provided satisfactory clinical results for patients with classic indications. However, MB-UKA tended to fail in early postoperative years whereas fixed-bearing UKA in later postoperative years. Therefore treatment options should be carefully considered for each patient, and surgeons should still use their personal experience when deciding between these options.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Knee Prosthesis , Postoperative Complications/epidemiology , Prosthesis Design/statistics & numerical data , Arthroplasty, Replacement, Knee/statistics & numerical data , Female , Femur/surgery , Humans , Knee/surgery , Knee Joint/surgery , Male , Osteoarthritis, Knee/surgery , Postoperative Complications/etiology , Postoperative Period , Prosthesis Design/adverse effects , Range of Motion, Articular , Recovery of Function , Reoperation/statistics & numerical data , Tibia/surgery , Treatment Outcome
8.
J Arthroplasty ; 34(7S): S292-S296, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31010773

ABSTRACT

BACKGROUND: Nonmodular and modular femoral stems have been associated with complications after revision total hip arthroplasty (rTHA). As such, the ideal femoral component for rTHA remains undecided. This study aims to report outcomes of titanium, tapered-fluted, modular and nonmodular femoral components in rTHA. METHODS: From January 1, 2013 to September 30, 2017, all rTHAs using modular or nonmodular femoral stems were identified. Demographic data including age, gender, and American Society of Anesthesiologists scores were collected. Surgical details including operative time and implant cost were also collected. Clinical outcomes including length of stay, dislocation, infection, fracture, reoperation, and re-revision were collected. Statistical analysis was performed using chi-square test and Student's t-test for all categorical and continuous variables, respectively. RESULTS: One hundred forty-six rTHA cases (103 modular and 43 nonmodular) were identified with an average follow-up of 29 months (range 3-59 months). Nonmodular stems had a significantly lower cost when compared to modular implants (modular stems 120.8% higher cost; P < .001). The surgical time of nonmodular components was significantly greater (193 minutes vs 163 minutes; P = .029). There were no differences observed in any other surgical details or clinical outcomes assessed, including length of stay (P = .323), rate of re-revision of the femoral implant (P = .389), rate of re-operation (P = .383), and postop complications (P = .241), including infection (P = .095), dislocation (P = .778), and fracture (P = .959). CONCLUSIONS: Nonmodular components provide encouraging clinical results with significantly lower costs compared to modular implants in rTHA. The use of titanium, tapered-fluted, nonmodular components may offer a more cost-effective approach to rTHA compared to their modular counterparts.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis/statistics & numerical data , Postoperative Complications/epidemiology , Prosthesis Design/statistics & numerical data , Aged , Chi-Square Distribution , Female , Femur/surgery , Fractures, Bone/epidemiology , Fractures, Bone/etiology , Hip Prosthesis/adverse effects , Humans , Joint Dislocations , Male , Middle Aged , New York City/epidemiology , Operative Time , Postoperative Complications/etiology , Prosthesis Design/adverse effects , Reoperation/statistics & numerical data , Retrospective Studies , Titanium
9.
J Arthroplasty ; 34(7S): S287-S291, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31005430

ABSTRACT

INTRODUCTION: Modular Dual Mobility (MDM) constructs in total hip arthroplasty (THA) offer increased hip stability compared with constrained liners, without compromising hip range of motion. The purpose of this study was to evaluate outcomes of revision THA using MDM. METHODS: The study was a multiinstitutional retrospective cohort study of 315 hips that underwent revision THA using MDM between 2011 and 2017. Clinical outcomes and reasons for failure were collected. RESULTS: Three hundred fifteen patients met 1-year minimum follow-up (mean 3.3 years). Nine hips had instability postoperatively (2.9%), and 30 hips required reoperation (9.5%). Seven had recurrent instability (6.5%) which was associated with liner-only exchange (P = .021) and liner outer diameter of ≤ 38 mm (P = .016). CONCLUSION: Revision THA with MDM provided a low rate of instability and reoperation in a revision cohort. Recurrent instability following use of MDM in revision THA was associated with retention of the acetabular component and polyethylene outer diameter ≤ 38 mm. LEVEL OF EVIDENCE: Therapeutic Level III.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis/statistics & numerical data , Prosthesis Design/statistics & numerical data , Reoperation/statistics & numerical data , Acetabulum/surgery , Aged , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/statistics & numerical data , Cohort Studies , Female , Humans , Joint Instability/epidemiology , Joint Instability/etiology , Male , Middle Aged , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Postoperative Period , Prosthesis Design/adverse effects , Range of Motion, Articular , Reoperation/adverse effects , Reoperation/instrumentation , Retrospective Studies , Time Factors , United States/epidemiology
10.
J Arthroplasty ; 33(6): 1800-1805, 2018 06.
Article in English | MEDLINE | ID: mdl-29428465

ABSTRACT

BACKGROUND: The primary aim was to evaluate the outcome of short-stem hip prostheses in terms of overall revision rates. Data were taken from published literature and national arthroplasty registers. The second study aim was to evaluate a potentially superior outcome of dependent compared to independent clinical studies. METHODS: All clinical studies on short-stem hip prostheses between 2006 and 2016 were reviewed and evaluated with a special interest on revision rates. Revision rate was calculated as "revision per 100 component years." Short stems were divided into femoral neck retaining (NR), neck sparing (NS), and neck harming (NH) prostheses. Published literature was further classified into dependent and independent studies, and data were compared to the Australian National Arthroplasty Register. RESULTS: Fifty-two studies with 56 cohorts met the inclusion criteria and were therefore included in our study. All clinical studies showed a median revision rate of 4.8% after 10 years. NS and NH stems performed equally, whereas neck retaining prostheses were significantly inferior. Independent showed higher revision rates compared to dependent data without being statistically significant. The Australian register revealed a revision rate of 6.6% after one decade. CONCLUSION: Similar low revision rates for NS and NH short-stem prostheses were found in the included data. Dependent studies seem not to be biased with regard to the longevity of short-stem hip replacement. Longer follow-up periods in clinical studies and more detailed information in arthroplasty registers would be desirable for future studies.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis/statistics & numerical data , Prosthesis Design/statistics & numerical data , Registries , Reoperation/statistics & numerical data , Arthroplasty, Replacement, Hip/statistics & numerical data , Australia , Clinical Studies as Topic , Humans , Prosthesis Failure , Prosthesis Retention
11.
Acta Orthop ; 89(4): 369-373, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29589467

ABSTRACT

Background and purpose - Although common in medical research, meta-analysis has not been widely adopted in registry collaborations. A meta-analytic approach in which each registry conducts a standardized analysis on its own data followed by a meta-analysis to calculate a weighted average of the estimates allows collaboration without sharing patient-level data. The value of meta-analysis as an alternative to individual patient data analysis is illustrated in this study by comparing the risk of revision of porous tantalum cups versus other uncemented cups in primary total hip arthroplasties from Sweden, Australia, and a US registry (2003-2015). Patients and methods - For both individual patient data analysis and meta-analysis approaches a Cox proportional hazard model was fit for time to revision, comparing porous tantalum (n = 23,201) with other uncemented cups (n = 128,321). Covariates included age, sex, diagnosis, head size, and stem fixation. In the meta-analysis approach, treatment effect size (i.e., Cox model hazard ratio) was calculated within each registry and a weighted average for the individual registries' estimates was calculated. Results - Patient-level data analysis and meta-analytic approaches yielded the same results with the porous tantalum cups having a higher risk of revision than other uncemented cups (HR (95% CI) 1.6 (1.4-1.7) and HR (95% CI) 1.5 (1.4-1.7), respectively). Adding the US cohort to the meta-analysis led to greater generalizability, increased precision of the treatment effect, and similar findings (HR (95% CI) 1.6 (1.4-1.7)) with increased risk of porous tantalum cups. Interpretation - The meta-analytic technique is a viable option to address privacy, security, and data ownership concerns allowing more expansive registry collaboration, greater generalizability, and increased precision of treatment effects.


Subject(s)
International Cooperation , Medical Records/statistics & numerical data , Meta-Analysis as Topic , Registries/statistics & numerical data , Arthroplasty, Replacement, Hip/statistics & numerical data , Australia , Cohort Studies , Hip Prosthesis/statistics & numerical data , Humans , Porosity , Prosthesis Design/statistics & numerical data , Prosthesis Failure , Sweden , Tantalum/therapeutic use , United States
12.
Colorectal Dis ; 19(4): 363-371, 2017 Apr.
Article in English | MEDLINE | ID: mdl-27496246

ABSTRACT

AIM: The object of this study was to compare function and quality of life after restorative proctocolectomy (RPC) with ileal pouch-anal anastomosis (IPAA) surgery having two different pouch designs. METHOD: Patients having RPC in an academic unit from 2000 who had had the loop-ileostomy closed by June 2013 were identified from the hospital medical records. They were sent a questionnaire regarding quality of life and interviewed using a pouch function score (PFS) described by Oresland (score 0-16, higher scores denote worse function). RESULTS: One hundred and three patients underwent surgery, of whom 56 had a J-pouch design and 47 a K-pouch design, this being a double-folded Kock pouch without the nipple valve. No patients have had the pouch removed or defunctioned due to failure at a mean of 8 years. The reoperation rate was 11.6%. The mean PFS was 5.43 and 5.27 for J- and K-pouches, respectively (P = 0.766). More patients with a J-pouch reported a social handicap due to poor bowel function (P = 0.041). Patients with a PFS ≥ 8 had a poorer quality of life. A score of ≥ 8 was reported by 16% of K-pouch and 25% of J-pouch patients (P = 0.29). CONCLUSION: RPC is a safe procedure with a low complication rate and good functional outcome. Small improvements in function have an impact on a patient's quality of life. Although the J-pouch is the most commonly used, the K-pouch has some advantages. Other pouch designs deserve further evaluation.


Subject(s)
Colonic Pouches/statistics & numerical data , Ileostomy/methods , Intestinal Diseases/surgery , Proctocolectomy, Restorative/instrumentation , Prosthesis Design/statistics & numerical data , Adolescent , Adult , Aged , Child , Female , Follow-Up Studies , Humans , Intestinal Diseases/physiopathology , Intestines/physiopathology , Intestines/surgery , Male , Middle Aged , Postoperative Complications/etiology , Proctocolectomy, Restorative/methods , Quality of Life , Recovery of Function , Reoperation/statistics & numerical data , Surveys and Questionnaires , Treatment Outcome , Young Adult
13.
J Arthroplasty ; 32(10): 3191-3199, 2017 10.
Article in English | MEDLINE | ID: mdl-28552447

ABSTRACT

BACKGROUND: Taper corrosion has been identified to be a major concern in total hip arthroplasty during the past years. So far, the mechanisms that lead to taper corrosion in modular taper junctions are not fully understood. However, it has been shown that corrosion is also influenced by the geometry and topography of the taper, and these parameters vary among the implant manufacturers. The purpose of this study was to investigate the variations of common stem and head tapers regarding design and surface characteristics. METHODS: An analysis of selected commercially available 12/14 stem and head tapers was performed. As geometric parameters, the taper angle, the opening taper diameter, and the taper length were measured using a coordinate measuring machine. Several topographic parameters were determined using a tactile roughness measurement instrument. RESULTS: Although all investigated tapers are so-called 12/14 tapers, this study showed that the stem and head tapers differ among the manufacturers. The stem tapers were clearly different in both geometry and topography, and the range in variation of the topographic parameter was greater than it was for the geometric parameter. In contrast, the head tapers were different in their geometry, although not in topography. CONCLUSION: Ultimately, this study provides an overview on the characteristics and variations of modular hip taper connections, and in addition, a new classification system regarding the surface finish is presented. These findings could be further considered in experimental corrosion or retrieval studies.


Subject(s)
Hip Prosthesis/statistics & numerical data , Prosthesis Design/statistics & numerical data , Arthroplasty, Replacement, Hip/instrumentation , Corrosion , Humans
14.
J Arthroplasty ; 32(2): 487-493, 2017 02.
Article in English | MEDLINE | ID: mdl-27639304

ABSTRACT

BACKGROUND: In total hip arthroplasty, short stems were developed as a bone-conserving alternative to traditional cementless stems. So far, there have been very few recorded medium to long-term results of these comparatively new implants. The aim of our retrospective study was to report on the survival of calcar-loading short stems. METHODS: All Metha stem implantations from 2004 to 2014 were recorded from the operation protocols (n = 1888). Due to the chronological development of the stem, 3 different versions were implanted: modular titanium stems with neck adapters from titanium or cobalt-chrome and monoblock stems. Patients were questioned by post about revision, dislocation, and satisfaction. RESULTS: Data were complete for 93% of the procedures (1090 monoblock stems, 314 modular stems with titanium neck, and 230 modular stems with cobalt chrome neck). Mean follow-up was 6 years (1-11 years). Fifteen modular titanium implants were affected by cone fractures (4%). Therefore, monoblock, modular cobalt chrome, and modular titanium implants were analyzed separately. The 7-year revision rate for monoblock stems was 1.5%; for modular cobalt-chrome stems it was 1.8%, and for modular titanium stems it was 5.3%. CONCLUSION: Our data show the midterm survival of the monoblock and modular cobalt-chrome implants equivalent to the traditional cementless stems. These might, therefore, be considered as a bone-conserving alternative for young and active patients.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis/statistics & numerical data , Prosthesis Design/statistics & numerical data , Adolescent , Adult , Aged , Arthroplasty, Replacement, Hip/statistics & numerical data , Chromium Alloys , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prosthesis Failure , Reoperation/statistics & numerical data , Retrospective Studies , Titanium , Young Adult
15.
J Arthroplasty ; 32(1): 155-160, 2017 01.
Article in English | MEDLINE | ID: mdl-27452136

ABSTRACT

BACKGROUND: The aim of the study was to compare the clinical and radiographic results of consecutive ceramic-on-ceramic bearings with and without a metal-backed titanium sleeve in patients undergoing total hip arthroplasty. METHODS: Eighty-five patients (64 women and 21 men; average age 55.2 years) were included in the A group without sleeve while 147 patients (116 women and 31 men; average age 54.2 years) were included in the B group with sleeve. Clinical and radiologic measurements at follow-up (range, 5-14 years; average, 8.1 years) were analyzed. RESULTS: The mean latest postoperative Harris Hip Score was 89.1 for patients from both groups. One joint (1.2%) in the A group displayed ceramic liner fracture, while no incidences of liner fracture occurred in the B group. Audible squeaking was observed in 1 joint (1.2%) in the A group and 1 (0.7%) in the B group. The mean annual liner rate of wear was 0.0049 and 0.0046 mm/y for the A group and B group, respectively. Three joints in the A group (3.5%) required revision total hip arthroplasty because of individual episodes of aseptic cup loosening, ceramic liner fracture, and infection. One joint in the B group (0.7%) required revision because of progressive osteolysis of the proximal femur. Ten-year Kaplan-Meier survivorship, based on an end point of component loosening and bearing failure, was 97.6% for the A group and 99.3% for the B group. CONCLUSION: There were no clinical, radiographic, or survivorship differences between groups.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis/statistics & numerical data , Prosthesis Design/statistics & numerical data , Adult , Aged , Ceramics , Female , Femur , Follow-Up Studies , Hip Prosthesis/adverse effects , Humans , Kaplan-Meier Estimate , Male , Metals , Middle Aged , Postoperative Period , Prosthesis Failure , Radiography , Risk Factors , Survivorship , Time Factors , Titanium , Treatment Outcome
16.
J Arthroplasty ; 32(12): 3698-3703, 2017 12.
Article in English | MEDLINE | ID: mdl-28803814

ABSTRACT

BACKGROUND: In revision total hip arthroplasty (THA), proximal femoral bone loss creates a challenge of achieving adequate stem fixation. The purpose of this study was to examine the outcomes of a monoblock, splined, tapered femoral stem in revision THA. METHODS: Outcomes of revision THA using a nonmodular, splined, tapered femoral stem from a single surgeon were reviewed. With a minimum of 2-year follow-up, there were 68 cases (67 patients). Paprosky classification was 3A or greater in 85% of the cases. Preoperative and postoperative Harris Hip Scores (HHS), radiographic subsidence and osseointegration, limb length discrepancy, complications, and reoperations were analyzed. RESULTS: The Harris Hip Score improved from 37.4 ± SD 19.4 preoperatively to 64.6 ± SD 21.8 at final follow-up (P < .001). There were 16 revision procedures-8 for septic indications and 8 for aseptic indications. Subsidence occurred at a rate of 3.0% and dislocation at 7.4%. Limb length discrepancy of more than 1 cm after revision was noted in 13.6% of patients. Bone ingrowth was observed in all but 4 patients (94.1%). At 4-year follow-up, Kaplan-Meier estimated survival was 72.9% (95% confidence interval [CI] 57.0-83.8) for all causes of revision, 86.6% (95% CI 72.0-93.9) for all aseptic revision, and 95.5% (95% CI 86.8-98.5) for aseptic femoral revision. CONCLUSION: Although complications were significant, revision for femoral aseptic loosening occurred in only 3 patients. Given the ability of this monoblock splined tapered stem to adequately provide fixation during complex revision THA, it remains a viable option in the setting of substantial femoral bone defects.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis/statistics & numerical data , Prosthesis Design/statistics & numerical data , Reoperation/instrumentation , Aged , Female , Femur/surgery , Hip Prosthesis/adverse effects , Humans , Joint Dislocations , Kaplan-Meier Estimate , Male , Middle Aged , Osseointegration , Postoperative Period , Retrospective Studies , Titanium
17.
J Arthroplasty ; 32(10): 3016-3023, 2017 10.
Article in English | MEDLINE | ID: mdl-28601246

ABSTRACT

BACKGROUND: The purpose of this study was to compare the long-term clinical results, radiographic results, range of knee motion, patient satisfaction, and the survival rate of Medial-Pivot posterior cruciate-substituting, knee prosthesis and a press-fit condylar (PFC) Sigma cruciate-retaining mobile-bearing knee prosthesis in the same patients. METHODS: One hundred eighty-two patients received Medial-Pivot knee prosthesis in one knee and a PFC Sigma knee prosthesis in the contralateral knee. The minimum duration of follow-up was 11 years (range, 11-12.6 years). RESULTS: The knees with a Medial-Pivot knee prosthesis had significantly worse results than those with a PFC Sigma knee prosthesis at the final follow-up with regard to the mean postoperative Knee Society knee scores (90 compared with 95 points), Western Ontario and McMaster Universities Osteoarthritis Index score (25 compared with 18 points), and range of knee motion (117° compared with 128°). Patients were more satisfied with PFC Sigma knee prosthesis (93%) than with Medial-Pivot knee prosthesis (75%). Complication rates were significantly higher in the Medial-Pivot knee group (26%) than those in the PFC Sigma knee group (6.5%). Radiographic results and survival rates (99% compared with 99.5%) were similar between the 2 groups. CONCLUSION: Although the long-term fixation and survival rate of both Medial-Pivot and PFC Sigma prostheses were similar, we observed a worse knee score, worse range of knee motion, and patient satisfaction was less in the Medial-Pivot knee group than in the PFC Sigma knee group. Furthermore, complication rate was also higher in the Medial-Pivot knee group than the other group.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Knee Prosthesis/statistics & numerical data , Patient Satisfaction/statistics & numerical data , Prosthesis Design/statistics & numerical data , Range of Motion, Articular , Aged , Bone and Bones/surgery , Female , Humans , Knee/surgery , Knee Joint/physiology , Knee Joint/surgery , Knee Prosthesis/adverse effects , Magnetic Resonance Imaging , Male , Middle Aged , Osteoarthritis, Knee/surgery , Postoperative Period , Prosthesis Design/adverse effects
18.
J Arthroplasty ; 31(11): 2628-2636, 2016 11.
Article in English | MEDLINE | ID: mdl-27538714

ABSTRACT

BACKGROUND: This meta-analysis compares the clinical performance of all-polyethylene tibial (APT) to the metal-backed tibial (MBT) components. METHODS: We included comparative studies in primary total knee arthroplasty involving APT and MBT implant components. The primary outcomes were function, durability, and reports of adverse events. RESULTS: Twenty-eight articles with 95 847 knees were available for synthesis. The meta-analysis showed an association of APT with lower revision rates (incidence rate ratio, 0.709; P = .002) and adverse events (incidence rate ratio, 0.785; P = .204). Moderator analyses were performed to determine the effect of posterior cruciate ligament status on outcome, and no statistically significant effect was found for revision risk or adverse events incidence. CONCLUSION: All-polyethylene tibial components seem to be an equal option, with less financial burden than the MBT.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Knee Prosthesis/statistics & numerical data , Prosthesis Design/statistics & numerical data , Arthroplasty, Replacement, Knee/adverse effects , Humans , Metals , Polyethylene , Posterior Cruciate Ligament , Recovery of Function , Tibia/surgery
19.
Acta Orthop ; 87(2): 120-5, 2016.
Article in English | MEDLINE | ID: mdl-26471977

ABSTRACT

BACKGROUND AND PURPOSE: There are 2 basic principles in cemented stem fixation: shape-closed and force-closed. We investigated 2 shape-closed straight stems, the Müller (MSS) and the Virtec (VSS), which differ only in geometrical cross section, to determine whether the difference in stem shape would affect the radiological results or long-term survival. PATIENTS AND METHODS: We included 711 hips (in 646 patients) that were operated on between July 1996 and July 2003. Patients randomly received either an MSS (n = 356) or a VSS (n = 355) and were followed prospectively. Radiographs taken at a follow-up of > 10 years were analyzed for osteolysis. Kaplan-Meier (KM) survival analysis was performed using various endpoints. We also performed Cox regression analysis to identify risk factors for aseptic loosening and osteolysis of the stem. RESULTS: After 10 years, KM survival with "revision of any component for any reason" was 92% (95% CI: 88-95) for the MSS and 95% (CI: 92-97) for the VSS (p = 0.1). With "revision for aseptic loosening of the stem" as the endpoint, KM survival was 96% (CI: 9-98) for the MSS and 98% (CI: 97-100) for the VSS (p = 0.2). Cox regression showed that none of the risk factors analyzed were independent regarding aseptic loosening of the stem or regarding osteolysis. INTERPRETATION: The MSS and the VSS showed excellent survival for aseptic loosening after 10 years. For the 2 different stem designs, we did not find any independent risk factors for aseptic loosening or development of osteolysis.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Osteolysis/epidemiology , Prosthesis Design/statistics & numerical data , Prosthesis Failure/trends , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/adverse effects , Female , Hip Joint/diagnostic imaging , Hip Joint/surgery , Hip Prosthesis/adverse effects , Hip Prosthesis/statistics & numerical data , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Osteolysis/etiology , Proportional Hazards Models , Prospective Studies , Prosthesis Design/adverse effects , Radiography , Randomized Controlled Trials as Topic , Reoperation/statistics & numerical data , Risk Factors , Treatment Outcome
20.
J Arthroplasty ; 30(12): 2143-8, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26195354

ABSTRACT

Lack of ACL and non-anatomic articular surfaces in contemporary total knee implants result in kinematic abnormalities. We hypothesized that such abnormalities may be addressed with a biomimetic bi-cruciate retaining (BCR) design having anatomical articular surfaces. We used dynamic computer simulations to compare kinematics among the biomimetic BCR, a contemporary BCR and cruciate-retaining implant for activities of daily living. During simulated deep knee bend, chair-sit and walking, the biomimetic BCR implant showed activity dependent kinematics similar to healthy knees in vivo. Restoring native knee geometry together with ACL preservation provided these kinematic improvements over contemporary ACL-preserving and ACL-sacrificing implants. Further clinical studies are required to determine if such biomimetic implants can result in more normal feeling knees and improve quality of life for active patients.


Subject(s)
Anterior Cruciate Ligament/physiology , Arthroplasty, Replacement, Knee/instrumentation , Knee Joint/physiology , Knee Prosthesis/statistics & numerical data , Prosthesis Design/statistics & numerical data , Activities of Daily Living , Adult , Biomechanical Phenomena , Biomimetics , Computer Simulation , Female , Healthy Volunteers , Humans , Knee Joint/surgery , Male , Models, Biological , Posterior Cruciate Ligament/physiology , Quality of Life , Range of Motion, Articular , Walking/physiology , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL