Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Tuberk Toraks ; 69(1): 39-48, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33853304

RESUMEN

INTRODUCTION: Th2/Th1 mix pathological pathway may be seen as a common set of low eosinophilic phenotype in severe allergic asthma. This may affect omalizumab treatment response. In our study, we aimed to investigate whether eosinophil count (EOS) and percentage (EOS%), eosinophil lymphocyte ratio (ELR) and neutrophil lymphocyte ratio (NLR) may predict omalizumab treatment. MATERIALS AND METHODS: Patients who received omalizumab treatment at least for one year in our allergy clinic were screened retrospectively. Baseline hemogram parameters, pre- and post-treatment emergency admissions, annual attacks requiring steroid use, hospitalizations, spirometric changes, and asthma control tests (ACT) were recorded. According the global efficacy assessment (phisician's GETE) scale patients was recorded as responder and nonresponder. By looking at EOS, EOS%, ELR and NLR distributions in these groups, the role of these parameters in representation of the treatment efficacy was investigated. RESULT: The study was carried out with 83 patients, 77.1% of whom were women with an average age of 50.03 ± 10.7. While ACT scores and FEV1, FEF25-75 was significantly increased, the number of emergency admissions, annual attacks and hospitalizations decreased significantly (p<0.05). The rate of patients signed as responder was 75.9%, while the rate of nonresponder was %24.1. When the two groups were compared, it was found that the EOS, EOS% and ELR were significantly higher in the responder group. The cut-off values according to the ROC curve were determined as 0.12, 310/ml and 3.1% respectively. Considering the sensitivity (58.73%); specificity (85.00%); positive predictive value (92.50%), it was determined that ELR was a more valuable test. CONCLUSIONS: Instead of expensive and invasive methods for predicting the response of omalizumab therapy in severe allergic asthma, the ELR is correlated with treatment response and giving hope to be easier way to reach.


Asunto(s)
Antiasmáticos/uso terapéutico , Asma/tratamiento farmacológico , Asma/metabolismo , Eosinófilos/metabolismo , Omalizumab/uso terapéutico , Adulto , Femenino , Humanos , Recuento de Leucocitos , Linfocitos/metabolismo , Masculino , Persona de Mediana Edad , Neutrófilos/metabolismo , Fenotipo , Curva ROC , Estudios Retrospectivos , Resultado del Tratamiento
2.
Food Chem ; 175: 273-9, 2015 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-25577080

RESUMEN

High Performance Liquid Chromatography LC-UV and LC-MS/MS methods were developed and validated for quantitative analyses of sodium benzoate and potassium sorbate in foods and beverages. HPLC-UV and LC-MS/MS methods were compared for quantitative analyses of sodium benzoate and potassium sorbate in a representative ketchup sample. Optimisation of the methods enabled the chromatographic separation of the analytes in less than 4 min. A correlation coefficient of 0.999 was achieved over the measured calibration range for both compounds and methods (HPLC and LC-MS/MS). The uncertainty values of sodium benzoate and potassium sorbate were found as 0.199 and 0.150 mg/L by HPLC and 0.072 and 0.044 mg/L by LC-MS/MS, respectively. Proficiency testing performance of Turkish accredited laboratories between the years 2005 and 2013 was evaluated and reported herein. The aim of the proficiency testing scheme was to evaluate the performance of the laboratories, analysing benzoate and sorbate in tomato ketchup.


Asunto(s)
Bebidas/análisis , Cromatografía Líquida de Alta Presión/métodos , Conservantes de Alimentos/química , Benzoato de Sodio/análisis , Ácido Sórbico/análisis , Espectrometría de Masas en Tándem/métodos , Benzoato de Sodio/química , Ácido Sórbico/química , Turquía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA