RESUMEN
OBJECTIVES: To assess the accuracy of ultrasound measurement of the lower uterine segment (LUS) thickness against findings at laparotomy, and to investigate its correlation with the success rate of vaginal birth after one previous caesarean delivery (CD) in a resource-limited setting. DESIGN: Prospective study. SETTING: Obstetrics and Gynaecology department in a tertiary hospital in Ghana. POPULATION: Women with one previous CD undergoing either a trial of labour (TOLAC) or elective CD. METHODS: Myometrial lower uterine segment thickness (mLUS) and full lower uterine segment thickness (fLUS) were measured with transvaginal ultrasound (TVUS). The women were managed according to local protocols with the clinicians blinded to the ultrasound measurements. The LUS was measured intraoperatively for comparison with ultrasound measurements. MAIN OUTCOME MEASURES: Lower uterine segment findings at laparotomy, successful vaginal birth. RESULTS: A total of 311 pregnant women with one previous CD were enrolled; 147 women underwent elective CD and 164 women underwent a TOLAC. Of the women that underwent TOLAC, 96 (58.5%) women had a successful vaginal birth. The mLUS was comparable to the intraoperative measurement in the elective CD group with LUS thickness <5 mm (bias of 0.01, 95% CI -0.10 to 0.12 mm) whereas fLUS overestimated LUS <5 mm (bias of 0.93, 95% CI 0.80-1.06 mm). Successful vaginal birth rate correlated with increasing mLUS values (odds ratio 1.30, 95% CI 1.03-1.64). Twelve cases of uterine defect were recorded. LUS measurement ≤2.0 mm was associated with an increased risk of uterine defects with a sensitivity of 91.7% (95% CI 61.5-99.8%) and specificity of 81.8% (95% CI 75.8-86.8%). CONCLUSION: Accurate TVUS measurement of the LUS is technically feasible in a resource-limited setting. This approach could help in making safer decisions on mode of birth in limited-resource settings.
Asunto(s)
Esfuerzo de Parto , Parto Vaginal Después de Cesárea , Humanos , Femenino , Embarazo , Estudios Prospectivos , Adulto , Ghana , Útero/diagnóstico por imagen , Ultrasonografía Prenatal , Valor Predictivo de las Pruebas , Ultrasonografía/métodos , Miometrio/diagnóstico por imagenRESUMEN
Intrauterine contraceptive device (IUCD) is among the commonly used contraceptive methods in the world including sub-Saharan Africa but have been associated with a number of complications that although rare, can occur. Uterine perforation is the most serious complication of the IUCD. Surgical management is required in cases with complete uterine perforation, in which the IUCD is partially or completely within the peritoneal cavity. We present a case of a 27year old para 2 woman reporting with mild lower abdominal pains and the absence of IUCD string in the vagina after its insertion following evacuation of the uterus 2 years prior to this study. With the utilization of multiple imaging modalities, an exploratory laparotomy was done to remove the migrated IUCD and repair of the perforated bowel and urinary bladder.