Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Br J Cancer ; 128(12): 2326-2337, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37076563

RESUMEN

BACKGROUND: Current strategies to inhibit androgen receptor (AR) are circumvented in castration-resistant prostate cancer (CRPC). Cyclin-dependent kinase 7 (CDK7) promotes AR signalling, in addition to established roles in cell cycle and global transcription, providing a rationale for its therapeutic targeting in CRPC. METHODS: The antitumour activity of CT7001, an orally bioavailable CDK7 inhibitor, was investigated across CRPC models in vitro and in xenograft models in vivo. Cell-based assays and transcriptomic analyses of treated xenografts were employed to investigate the mechanisms driving CT7001 activity, alone and in combination with the antiandrogen enzalutamide. RESULTS: CT7001 selectively engages with CDK7 in prostate cancer cells, causing inhibition of proliferation and cell cycle arrest. Activation of p53, induction of apoptosis, and suppression of transcription mediated by full-length and constitutively active AR splice variants contribute to antitumour efficacy in vitro. Oral administration of CT7001 represses growth of CRPC xenografts and significantly augments growth inhibition achieved by enzalutamide. Transcriptome analyses of treated xenografts indicate cell cycle and AR inhibition as the mode of action of CT7001 in vivo. CONCLUSIONS: This study supports CDK7 inhibition as a strategy to target deregulated cell proliferation and demonstrates CT7001 is a promising CRPC therapeutic, alone or in combination with AR-targeting compounds.


Asunto(s)
Neoplasias de la Próstata Resistentes a la Castración , Masculino , Humanos , Neoplasias de la Próstata Resistentes a la Castración/tratamiento farmacológico , Neoplasias de la Próstata Resistentes a la Castración/genética , Neoplasias de la Próstata Resistentes a la Castración/metabolismo , Línea Celular Tumoral , Ensayos Antitumor por Modelo de Xenoinjerto , Receptores Androgénicos/genética , Receptores Androgénicos/metabolismo , Nitrilos/uso terapéutico , Quinasas Ciclina-Dependientes/uso terapéutico , Inhibidores Enzimáticos/uso terapéutico , Proliferación Celular
3.
Nanotechnology ; 29(11): 115501, 2018 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-29319001

RESUMEN

An enzyme-free glucose sensor based on vertically grown zinc oxide nanorods (NRs) functionalized with ferric oxide (Fe2O3) is investigated. The well-aligned and high density ZnO NRs were synthesized on an FTO/glass substrate by a sol-gel and hydrothermal growth method. A dip-coating technique was utilized to modify the surface of the as-grown ZnO NRs with Fe2O3. The immobilized surface was coated with a layer of nafion membrane. The fabricated glucose sensor was characterized amperometrically at room temperature using three electrodes stationed in the phosphate buffer solution, where ZnO NRs/Fe2O3/nafion membrane was the sensing or working electrode, and platinum plate and silver/silver chloride were used as the counter and reference electrodes, respectively. The proposed non-enzymatic and modified glucose sensor exhibited a high sensitivity in the order of 0.052 µA cm-2 (mg/dL)-1, a lower detection limit of around 0.95 mmol L-1, a sharp and fast response time of ∼1 s, and a linear response to changes in glucose concentrations from 100-400 mg dL-1. The linear amperometric response of the sensor covers the physiological and clinical interest of glucose levels for diabetic patients. The device continues to function accurately after multiple measurements with a good reproducibility. The proposed glucose sensor is expected to be used clinically for in vivo monitoring of glucose.


Asunto(s)
Compuestos Férricos/química , Glucosa/análisis , Nanotubos/química , Óxido de Zinc/química , Electrodos , Polímeros de Fluorocarbono/química , Nanotubos/ultraestructura , Reproducibilidad de los Resultados , Difracción de Rayos X
4.
Lab Chip ; 5(11): 1327-30, 2005 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16234960

RESUMEN

A bead-based microfluidic device was developed and demonstrated to achieve rapid and sensitive enzyme-linked immunosorbent assay (ELISA) with quantum dots as the labeling fluorophore for virus detection. In comparison to standard ELISA performed on the same virus, the minimal detectable concentration of the target virus was improved from 360 to 22 ng mL-1, the detection time was shortened from >3.25 h to <30 min, and the amount of antibody consumed was reduced by a factor of 14.3.


Asunto(s)
Ensayo de Inmunoadsorción Enzimática/instrumentación , Ensayo de Inmunoadsorción Enzimática/métodos , Iridovirus/aislamiento & purificación , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Animales , Iridovirus/química , Iridovirus/inmunología , Virología/métodos
5.
Lab Chip ; 4(4): 337-41, 2004 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-15269801

RESUMEN

A filter-based microfluidic device was combined with immunofluorescent labeling as a platform to rapidly detect microbial cells. The coin-sized device consisted of micro-chambers, micro-channels and filter weirs (gap = 1-2 microm), and was demonstrated to effectively trap and concentrate microbial cells (i.e., Cryptosporidium parvum and Giardia lamblia), which were larger in size than the weir gap. After sample injection, a staining solution containing fluorescently-labeled antibodies was continuously provided into the device (flow rate = 20 microl min(-1)) to flush the microbial cells toward the weirs and to accelerate the fluorescent labeling reaction. Using a staining solution that was 10 to 100 times more dilute than the recommended concentration used in a conventional glass method, those target cells with a fluorescent signal-to-noise ratio of 12 could be microscopically observed at single-cell level within 2 to 5 min prior to secondary washing.


Asunto(s)
Cryptosporidium parvum/aislamiento & purificación , Técnica del Anticuerpo Fluorescente Indirecta/métodos , Giardia lamblia/aislamiento & purificación , Microfluídica/instrumentación , Microfluídica/métodos , Animales , Cryptosporidium parvum/citología , Cryptosporidium parvum/inmunología , Filtración/instrumentación , Fluoroinmunoensayo/métodos , Giardia lamblia/citología , Giardia lamblia/inmunología
6.
Anal Chim Acta ; 556(1): 171-7, 2006 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-17723345

RESUMEN

This paper reported the development of a microfludic device for the rapid detection of viable and nonviable microbial cells through dual labeling by fluorescent in situ hybridization (FISH) and quantum dots (QDs)-labeled immunofluorescent assay (IFA). The coin sized device consists of a microchannel and filtering pillars (gap=1-2 microm) and was demonstrated to effectively trap and concentrate microbial cells (i.e. Giardia lamblia). After sample injection, FISH probe solution and QDs-labeled antibody solution were sequentially pumped into the device to accelerate the fluorescent labeling reactions at optimized flow rates (i.e. 1 and 20 microL/min, respectively). After 2 min washing for each assay, the whole process could be finished within 30 min, with minimum consumption of labeling reagents and superior fluorescent signal intensity. The choice of QDs 525 for IFA resulted in bright and stable fluorescent signal, with minimum interference with the Cy3 signal from FISH detection.

7.
Appl Environ Microbiol ; 70(1): 597-8, 2004 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-14711692

RESUMEN

Semiconductor quantum dot-conjugated antibodies were successfully developed to label Cryptosporidium parvum and Giardia lamblia. This novel fluorescence system exhibited superior photostability, gave 1.5- to 9-fold-higher signal-to-noise ratios than traditional organic dyes in detecting C. parvum, and allowed dual-color detection for C. parvum and G. lamblia.


Asunto(s)
Cryptosporidium parvum/aislamiento & purificación , Colorantes Fluorescentes , Giardia lamblia/aislamiento & purificación , Puntos Cuánticos , Animales , Anticuerpos Antiprotozoarios/inmunología , Técnica del Anticuerpo Fluorescente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA